Grid-side converter control of DFIG wind turbines to enhance power quality of distribution network

A doubly fed induction generator wind turbine (DFIG-WT) with FACTS capabilities is presented. It is suggested to make use of the grid-side converter as a shunt active filter in order to support the grid with power factor correction as well as harmonic compensation. A vector control scheme is used to control the grid-side converter with a priority level feature to split extra room for compensation. It allows the grid-side converter to be remote-controlled and provide power quality support at a specific point away from the wind turbines plant. No harmonics are injected into the generator and the system is fully operational even at zero output power from the DFIG-WT. Simulation results illustrate good performance of the proposed system

[1]  S.A. Gomez,et al.  Grid synchronisation of doubly fed induction generators using direct torque control , 2002, IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02.

[2]  K. Al-Haddad,et al.  Performance comparison of two current control techniques applied to an active filter , 1998, 8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227).

[3]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[4]  Frede Blaabjerg,et al.  Transient stability of DFIG wind turbines at an external short‐circuit fault , 2005 .

[5]  Marian P. Kazmierkowski,et al.  Direct torque control of PWM inverter-fed AC motors - a survey , 2004, IEEE Transactions on Industrial Electronics.

[6]  Jonas Persson,et al.  Dynamic Response of Grid-Connected Wind Turbine with Doubly Fed Induction Generator during Disturbances , 2004 .

[7]  T. Thiringer,et al.  Evaluation of current control methods for wind turbines using doubly-fed induction machines , 2005, IEEE Transactions on Power Electronics.

[8]  P. Vas Vector control of AC machines , 1990 .

[9]  Stefan Lundberg,et al.  A DFIG wind turbine ride‐through system. Influence on the energy production , 2004 .

[10]  N.W. Miller,et al.  Dynamic modeling of GE 1.5 and 3.6 MW wind turbine-generators for stability simulations , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[11]  Hamid A. Toliyat,et al.  A sensorless integrated doubly-fed electric alternator/active filter (IDEA) for variable speed wind energy system , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[12]  M. Yamamoto,et al.  Active and reactive power control of doubly-fed wound rotor induction generator , 1990, 21st Annual IEEE Conference on Power Electronics Specialists.

[13]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[14]  A. Trzynadlowski The Field Orientation Principle in Control of Induction Motors , 1993 .

[15]  C. Watthanasarn,et al.  A matrix converter excited doubly-fed induction machine as a wind power generator , 1998 .

[16]  Arthur R. Bergen,et al.  Power Systems Analysis , 1986 .

[17]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.