Command functions of open loop galvanometer scanners with optimized duty cycles

The paper approaches the problem of the command functions of galvanometer-based scanners (GS) that are necessary to produce the linear plus parabolic scanning function of the GS, which we have proved previously to produce the highest possible duty cycle (i.e., time efficiency) of the device. We have completed this theoretical aspect (which contradicted what has been stated previously in the literature, where it has been considered that the linear plus sinusoidal scanning function was the best) with the experimental study of the most used scanning functions of the GSs (sawtooth, sinusoidal and triangular), with applications in biomedical imaging, in particular in optical coherence tomography, demonstrating that the triangular function is always the best one to be applied, from both an optical and a mechanical point of view. In the present study the input voltage/command function which should be applied to the GS to produce the desired triangular scanning function (with controlled non-linearity for the fastest possible stop-and-turn portions) was determined analytically, in relationship with the active torque that drives the device. This command function is analyzed with regard to the specific, respectively required parameters of the GS: natural frequency and damping factor, respectively scan speed and amplitude. The modeling in an open loop control structure of the GS is finally discussed as a trade-off between using the highest possible duty cycle and minimizing the maximum peaks of the input voltage.

[1]  Hyungsuck Cho,et al.  Optical design of a variable view imaging system with the combination of a telecentric scanner and double wedge prisms. , 2010, Applied optics.

[2]  Maciej Wojtkowski,et al.  Scanning protocols dedicated to smart velocity ranging in spectral OCT. , 2009, Optics express.

[3]  Kevin Hsu,et al.  Dual detection full range frequency domain optical coherence tomography. , 2010, Optics letters.

[4]  Michael Pircher,et al.  Full range complex spectral domain optical coherence tomography without additional phase shifters. , 2007, Optics express.

[5]  M. Jenkins,et al.  In vivo gated 4D imaging of the embryonic heart using optical coherence tomography. , 2007, Journal of biomedical optics.

[6]  Yajun Li Single-mirror beam steering system: analysis and synthesis of high-order conic-section scan patterns. , 2008, Applied optics.

[7]  Virgil-Florin Duma,et al.  Optimal scanning function of a galvanometer scanner for an increased duty cycle , 2010 .

[8]  David A. Jackson,et al.  En-face coherence imaging using galvanometer scanner modulation. , 1998, Optics letters.

[9]  Adrian Gh. Podoleanu,et al.  Combinations of techniques in imaging the retina with high resolution , 2008, Progress in Retinal and Eye Research.

[10]  Virgil-Florin Duma,et al.  Experimental investigations of the scanning functions of galvanometer-based scanners with applications in OCT. , 2011, Applied optics.

[11]  P. So,et al.  High-speed, two-photon scanning microscope. , 1999, Applied optics.