Investigation of condition monitoring of transformer winding based on detection simulated transient overvoltage response

In order to keep the original connection of transformer, a novel method and apparatus is proposed for condition monitoring of transformer winding based on the detection of transient overvoltage signals. Firstly, a lumped parameter model of transformer winding is established to verify the equivalence in frequency response analysis between the overvoltage and sweep frequency voltage. Then experimental study is conducted on different types of winding faults, to conform the capability to identify the winding fault types. And the investigation of condition monitoring of 110 kV transformer is conducted. The over-voltage frequency response method is verified and can be applied to online monitoring of field windings.

[1]  E.P. Dick,et al.  Transformer Diagnostic Testing by Frequuency Response Analysis , 1978, IEEE Transactions on Power Apparatus and Systems.

[2]  K. D. Srivastava,et al.  Condition monitoring of transformers in service by the low voltage impulse test method , 1999 .

[3]  Syed Islam Detection of shorted turns and winding movements in large power transformers using frequency response analysis , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[4]  A.J. Vandermaar,et al.  Improved detection of power transformer winding movement by extending the FRA high frequency range , 2005, IEEE Transactions on Power Delivery.

[5]  W. Ziomek,et al.  High voltage power transformer insulation design , 2011, 2011 Electrical Insulation Conference (EIC)..

[6]  Gholamreza Moradi,et al.  Online monitoring of transformer winding axial displacement and its extent using scattering parameters and k-nearest neighbour method , 2011 .

[7]  A. Abu-Siada,et al.  A Novel Online Technique to Detect Power Transformer Winding Faults , 2012, IEEE Transactions on Power Delivery.

[8]  Li Chengxiang Selection of Waveform for DC-steep Pulse Field in Transformer Oil Purifying , 2012 .

[9]  M. S. Naderi,et al.  Advanced transformer winding deformation diagnosis: moving from off-line to on-line , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  Mehdi Bagheri,et al.  Frequency response analysis and short-circuit impedance measurement in detection of winding deformation within power transformers , 2013, IEEE Electrical Insulation Magazine.

[11]  A. Abu-Siada,et al.  Impact of axial displacement on power transformer FRA signature , 2013, 2013 IEEE Power & Energy Society General Meeting.

[12]  A. Abu-Siada,et al.  Understanding power transformer frequency response analysis signatures , 2013, IEEE Electrical Insulation Magazine.

[13]  Chenguo Yao,et al.  Transformer winding deformation diagnostic system using online high frequency signal injection by capacitive coupling , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  Mi Ya Development of Circulative Reactor Used for Purification of Contaminated Transformer Oil with DC-steep Pulse Electric Field , 2014 .