Investigation of condition monitoring of transformer winding based on detection simulated transient overvoltage response
暂无分享,去创建一个
Chenguo Yao | Chengxiang Li | Xiaozhen Zhao | Zhongyong Zhao | Shoulong Dong | Chengxiang Li | C. Yao | Shoulong Dong | Zhongyong Zhao | Xiaozhen Zhao
[1] E.P. Dick,et al. Transformer Diagnostic Testing by Frequuency Response Analysis , 1978, IEEE Transactions on Power Apparatus and Systems.
[2] K. D. Srivastava,et al. Condition monitoring of transformers in service by the low voltage impulse test method , 1999 .
[3] Syed Islam. Detection of shorted turns and winding movements in large power transformers using frequency response analysis , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).
[4] A.J. Vandermaar,et al. Improved detection of power transformer winding movement by extending the FRA high frequency range , 2005, IEEE Transactions on Power Delivery.
[5] W. Ziomek,et al. High voltage power transformer insulation design , 2011, 2011 Electrical Insulation Conference (EIC)..
[6] Gholamreza Moradi,et al. Online monitoring of transformer winding axial displacement and its extent using scattering parameters and k-nearest neighbour method , 2011 .
[7] A. Abu-Siada,et al. A Novel Online Technique to Detect Power Transformer Winding Faults , 2012, IEEE Transactions on Power Delivery.
[8] Li Chengxiang. Selection of Waveform for DC-steep Pulse Field in Transformer Oil Purifying , 2012 .
[9] M. S. Naderi,et al. Advanced transformer winding deformation diagnosis: moving from off-line to on-line , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.
[10] Mehdi Bagheri,et al. Frequency response analysis and short-circuit impedance measurement in detection of winding deformation within power transformers , 2013, IEEE Electrical Insulation Magazine.
[11] A. Abu-Siada,et al. Impact of axial displacement on power transformer FRA signature , 2013, 2013 IEEE Power & Energy Society General Meeting.
[12] A. Abu-Siada,et al. Understanding power transformer frequency response analysis signatures , 2013, IEEE Electrical Insulation Magazine.
[13] Chenguo Yao,et al. Transformer winding deformation diagnostic system using online high frequency signal injection by capacitive coupling , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.
[14] Mi Ya. Development of Circulative Reactor Used for Purification of Contaminated Transformer Oil with DC-steep Pulse Electric Field , 2014 .