Estimation of presampling modulation transfer function in synchrotron radiation microtomography

The spatial resolution achieved by recent synchrotron radiation microtomographs should be estimated from the modulation transfer function (MTF) on the micrometer scale. Step response functions of a synchrotron radiation microtomograph were determined by the slanted edge method by using high-precision surfaces of diamond crystal and ion-milled aluminum wire. Tilted reconstruction was introduced to enable any edge to be used as the slanted edge by defining the reconstruction pixel matrix in an arbitrary orientation. MTFs were estimated from the step response functions of the slanted edges. The obtained MTFs coincided with MTF values estimated from square-wave patterns milled on the aluminum surface. Although X-ray refraction influences should be taken into account to evaluate MTFs, any flat surfaces with nanometer roughness can be used to determine the spatial resolutions of microtomographs.

[1]  S. Wilkins,et al.  Linear algorithms for phase retrieval in the Fresnel region. 2. Partially coherent illumination , 2006 .

[2]  Kentaro Uesugi,et al.  Development of high spatial resolution X-ray CT system at BL47XU in SPring-8 , 2001 .

[3]  P. Cloetens,et al.  Advances in synchrotron radiation microtomography , 2006 .

[4]  Kentaro Uesugi,et al.  X-ray refraction-enhanced imaging and a method for phase retrieval for a simple object. , 2002, Journal of synchrotron radiation.

[5]  Mark S. Rzeszotarski,et al.  Modulation Transfer Function From The Variance Of Cyclic Bar Images , 1984 .

[6]  A. Peterzol,et al.  X-ray phase contrast image simulation , 2007 .

[7]  R T Droege,et al.  An MTF method immune to aliasing. , 1985, Medical physics.

[8]  S J Riederer,et al.  Ripple suppression during reconstruction in transverse tomography. , 1975, Physics in medicine and biology.

[9]  Kentaro Uesugi,et al.  Submicrometer tomographic resolution examined using a micro-fabricated test object. , 2010, Micron.

[10]  J. Herzen,et al.  SRμCT study of crack propagation within laser-welded aluminum-alloy T-joints , 2008, Optical Engineering + Applications.

[11]  Marco Stampanoni,et al.  X-ray Tomographic Microscopy at TOMCAT , 2009 .

[12]  P. Cloetens,et al.  Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays , 1999 .

[13]  Grant T. Gullberg,et al.  Users Manual: Donner Algorithms for Reconstruction Tomography , 1977 .

[14]  Kentaro Uesugi,et al.  Construction and Commissioning of A 248 m‐long Beamline with X‐ray Undulator Light Source , 2004 .

[15]  I. Robinson,et al.  Three-dimensional imaging of microstructure in Au nanocrystals. , 2003, Physical review letters.

[16]  S. Stock Recent advances in X-ray microtomography applied to materials , 2008 .

[17]  Kentaro Uesugi,et al.  High-definition high-throughput micro-tomography at SPring-8 , 2009 .

[18]  Hong Liu,et al.  Phase-contrast X-ray tomography: contrast mechanism and roles of phase retrieval. , 2008, European journal of radiology.

[19]  P. Judy,et al.  The line spread function and modulation transfer function of a computed tomographic scanner. , 1976, Medical physics.

[20]  Kentaro Uesugi,et al.  Evaluation of the improved three-dimensional resolution of a synchrotron radiation computed tomograph using a micro-fabricated test pattern. , 2008, Journal of synchrotron radiation.