Measurement of the Intertablet Coating Uniformity of a Pharmaceutical Pan Coating Process With Combined Terahertz and Optical Coherence Tomography In-Line Sensing.

We present in-line coating thickness measurements acquired simultaneously using 2 independent sensing modalities: terahertz pulsed imaging (TPI) and optical coherence tomography (OCT). Both techniques are sufficiently fast to resolve the coating thickness of individual pharmaceutical tablets in situ during the film coating operation, and both techniques are direct structural imaging techniques that do not require multivariate calibration. The TPI sensor is suitable to measure coatings greater than 50 μm and can penetrate through thick coatings even in the presence of pigments over a wide range of excipients. Due to the long wavelength, terahertz radiation is not affected by scattering from dust within the coater. In contrast, OCT can resolve coating layers as thin as 20 μm and is capable of measuring the intratablet coating uniformity and the intertablet coating thickness distribution within the coating pan. However, the OCT technique is less robust when it comes to the compatibility with excipients, dust, and potentially the maximum coating thickness that can be resolved. Using a custom-built laboratory scale coating unit, the coating thickness measurements were acquired independently by the TPI and OCT sensors throughout a film coating operation. Results of the in-line TPI and OCT measurements were compared against one another and validated with off-line TPI and weight gain measurements. Compared with other process analytical technology sensors, such as near-infrared and Raman spectroscopy, the TPI and OCT sensors can resolve the intertablet thickness distribution based on sampling a significant fraction of the tablet populations in the process. By combining 2 complementary sensing modalities, it was possible to seamlessly monitor the coating process over the range of film thickness from 20 μm to greater than 250 μm.

[1]  Carl Wassgren,et al.  Inter-tablet coating variability: Tablet residence time variability , 2009 .

[2]  C Vervaet,et al.  Near infrared and Raman spectroscopy for the in-process monitoring of pharmaceutical production processes. , 2011, International journal of pharmaceutics.

[3]  Linda A. Felton,et al.  Aqueous Polymeric Coatings for Pharmaceutical Dosage Forms , 2016 .

[4]  Yaochun Shen,et al.  Quantifying Pharmaceutical Film Coating with Optical Coherence Tomography and Terahertz Pulsed Imaging: An Evaluation , 2015, Journal of pharmaceutical sciences.

[5]  Yalin Zheng,et al.  Reconstruction of 3D surface maps from anterior segment optical coherence tomography images using graph theory and genetic algorithms , 2016, Biomed. Signal Process. Control..

[6]  Shuncong Zhong,et al.  Terahertz in-line sensor for direct coating thickness measurement of individual tablets during film coating in real-time. , 2011, Journal of pharmaceutical sciences.

[7]  Edward R Grant,et al.  Raman spectroscopic measurement of tablet-to-tablet coating variability. , 2005, Journal of pharmaceutical and biomedical analysis.

[8]  Günther Hannesschläger,et al.  In-Line Monitoring of a Pharmaceutical Pan Coating Process by Optical Coherence Tomography. , 2015, Journal of pharmaceutical sciences.

[9]  P. Kleinebudde,et al.  PAT-tools for process control in pharmaceutical film coating applications. , 2013, International journal of pharmaceutics.

[10]  P. Taday,et al.  Development and Application of Terahertz Pulsed Imaging for Nondestructive Inspection of Pharmaceutical Tablet , 2008, IEEE Journal of Selected Topics in Quantum Electronics.

[11]  M. Koch,et al.  Properties of Building and Plastic Materials in the THz Range , 2007 .

[12]  J. Zeitler,et al.  Diffusion and Swelling Measurements in Pharmaceutical Powder Compacts Using Terahertz Pulsed Imaging , 2015, Journal of pharmaceutical sciences.

[13]  Yaochun Shen,et al.  Impact of Processing Conditions on Inter-tablet Coating Thickness Variations Measured by Terahertz In-Line Sensing , 2015, Journal of pharmaceutical sciences.

[14]  J. Drennen,et al.  Near-Infrared Spectroscopic Monitoring of the Film Coating Process , 1996, Pharmaceutical Research.

[15]  Günther Hannesschläger,et al.  Optical coherence tomography as a novel tool for in-line monitoring of a pharmaceutical film-coating process. , 2014, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[16]  Ismini Charalambous,et al.  Correction of distortions in optical coherence tomography imaging of the eye. , 2004, Physics in medicine and biology.

[17]  Peter Kleinebudde,et al.  Prediction of dissolution time and coating thickness of sustained release formulations using Raman spectroscopy and terahertz pulsed imaging. , 2012, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[18]  P. Pääkkönen,et al.  On the Correlation of Effective Terahertz Refractive Index and Average Surface Roughness of Pharmaceutical Tablets , 2016 .

[19]  Günther Hannesschläger,et al.  Automated pharmaceutical tablet coating layer evaluation of optical coherence tomography images , 2015 .

[20]  Boštjan Likar,et al.  In-line monitoring of pellet coating thickness growth by means of visual imaging. , 2014, International journal of pharmaceutics.

[21]  J. Zeitler,et al.  Investigation of pharmaceutical film coating process with terahertz sensing, optical coherence tomography and numerical modelling , 2015, 2015 40th International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz).

[22]  Peter Kleinebudde,et al.  Validation of Terahertz coating thickness measurements using X-ray microtomography. , 2012, Molecular pharmaceutics.

[23]  San Kiang,et al.  Raman spectroscopy for the determination of coating uniformity of tablets: assessment of product quality and coating pan mixing efficiency during scale-up , 2007, Journal of Pharmaceutical Innovation.