Wavelength adjustment using an eye model from aberrometry data.

We developed a method to convert aberrometry data obtained in one wavelength to the corresponding data in another wavelength using an eye model. A single map of aberrometry data is used to construct a free-form one-surface eye model. A general algorithm for the surface construction is described and implemented for real aberrometry data. Our method can handle varying conjugate distances of the measurement plane of the aberrometer and can also manage the chief ray prism that may be present. The algorithm is validated with the aid of an artificial plastic eye. The wavefronts in different wavelengths are compared through the Zernike analysis not only for lower-order aberrations, but also for higher-order aberrations. The results show that the changes of the Zernike aberration coefficients due to wavelengths are non-uniform. The defocus term has the highest effect from wavelength changes, which is consistent with the previous literature. Our method is compared with two approximate semi-analytical algorithms. The wavelength adjustments from a multi-surface eye model are contrasted with our method. We prove analytically that the conventional method of wavelength adjustment is based on paraxial analysis. In addition, we provide a method of finding the chief ray using back-projection in some cases and discuss different meanings of prism.

[1]  Jayoung Nam,et al.  Weighted Zernike expansion with applications to the optical aberration of the human eye. , 2005, Journal of the Optical Society of America. A, Optics, image science, and vision.

[2]  R. Navarro,et al.  Accommodation-dependent model of the human eye with aspherics. , 1985, Journal of the Optical Society of America. A, Optics and image science.

[3]  R. West,et al.  Measurement of Refractive Errors in Young Myopes Using the COAS Shack-Hartmann Aberrometer , 2003, Optometry and vision science : official publication of the American Academy of Optometry.

[4]  John A. Kneisly Local Curvature of Wavefronts in an Optical System , 1964 .

[5]  Sowmya Ravikumar,et al.  Calculation of retinal image quality for polychromatic light. , 2008, Journal of the Optical Society of America. A, Optics, image science, and vision.

[6]  A. Bradley,et al.  Theory and measurement of ocular chromatic aberration , 1990, Vision Research.

[7]  Jacob Rubinstein,et al.  Reconstruction of Optical Surfaces from Ray Data , 2001 .

[8]  Arthur Bradley,et al.  Validation of a Clinical Shack-Hartmann Aberrometer , 2003, Optometry and vision science : official publication of the American Academy of Optometry.

[9]  D. Lara-Saucedo,et al.  Aberrations of the Human Eye in Visible and Near Infrared Illumination , 2003, Optometry and vision science : official publication of the American Academy of Optometry.

[10]  L. Thibos,et al.  Standards for reporting the optical aberrations of eyes. , 2002, Journal of refractive surgery.

[11]  L N Thibos,et al.  Statistical distribution of foveal transverse chromatic aberration, pupil centration, and angle psi in a population of young adult eyes. , 1995, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  Jörgen Gustafsson,et al.  Off-axis wave front measurements for optical correction in eccentric viewing. , 2005, Journal of biomedical optics.

[13]  Michael D Twa,et al.  Importance of fixation, pupil center, and reference axis in ocular wavefront sensing, videokeratography, and retinal image quality , 2009, Journal of cataract and refractive surgery.

[14]  A. Bradley,et al.  The chromatic eye: a new reduced-eye model of ocular chromatic aberration in humans. , 1992, Applied optics.

[15]  J. Rubinstein,et al.  Eikonal Functions: Old and New , 2004 .