Flexible two-phase thermosyphon for power electronic cooling

A two phase thermosyphon system for power electronic cooling is presented. The designed evaporator can house multiple power electronics modules, it collects the generated vapor to a common flexible tube that drives the vapor to a plate heat exchanger condenser. The system was tested and simulated for a total power loss of 12.5 kW. The condenser was installed at a distance of 3 m from the evaporator enabling flexibility from a customer side concerning location and distance where the heat is finally dumped to ambient. The evaporator is a novel design and it consists of a bottom liquid collector (i.e. it is a pool of liquid constantly feeding the evaporator channels) and a two-phase mixture collector at the top evaporator that collects the discharged two-phase flow and separates the liquid part from the vapor allowing the vapor to travel without liquid to the condenser. The system works with gravity driven circulation. Thermal performances of the system are presented and compared to the simulation results of a dedicated two-phase code developed by ABB. The total power dissipation investigated ranges between 5 and 12.5 kW. This is attained by three power modules Econopack Plus from Infineon. The condensation is provided by means of a water cooled plate heat exchanger. Results will be presented for a cooling water temperature of 38 and 50 °C. The working fluid was refrigerant R245fa.

[1]  Rahmatollah Khodabandeh Heat transfer in the evaporator of an advanced two-phase thermosyphon loop , 2005 .

[2]  Danny Lathouwers,et al.  A numerical study of boiling flow instability of a reactor thermosyphon system , 2006 .

[3]  Rahmatollah Khodabandeh,et al.  Choosing Working Fluid for Two-Phase Thermosyphon Systems for Cooling of Electronics , 2003 .

[4]  Michel Mermet-Guyennet,et al.  Local thermal cycles determination in thermosyphon-cooled traction IGBT modules reproducing mission profiles , 2007, Microelectron. Reliab..

[5]  M. Habert,et al.  Measurement Of The Performances Of ATransparent Closed Loop Two-phaseThermosyphon , 2010 .

[6]  I. Mudawar,et al.  Smart pumpless loop for micro-channel electronic cooling using flat and enhanced surfaces , 2003 .

[7]  Hosny Z. Abou-Ziyan,et al.  Performance of stationary and vibrated thermosyphon working with water and R134a , 2001 .

[8]  K. S. Ong,et al.  Performance of a R-134a-filled thermosyphon , 2003 .

[9]  Yuichi Mitsutake,et al.  CHF characteristics and correlations of concentric-tube open thermosyphon working with R22 , 2005 .

[10]  I. Mudawar,et al.  Pumpless Loop for Narrow Channel and Micro-Channel Boiling compact cooling system is examined which capitalizes upon fluid density differences , 2003 .

[11]  Rahmatollah Khodabandeh Pressure drop in riser and evaporator in an advanced two-phase thermosyphon loop , 2005 .

[12]  Aliakbar Akbarzadeh,et al.  The effects of non-condensable gases on the performance of loop thermosyphon heat exchangers , 2004 .