An Experimental Investigation of the Natural Convection of a Heat Generating Fluid within a Closed Vertical Cylinder

Experimental results are presented of the velocity and temperature distributions within a heat-generating fluid contained in a vertical closed cylinder, for the case in which the outer surface of the cylinder wall is maintained at a uniform temperature. Previous experimental data are compared and an earlier theoretical model for a different thermal boundary condition is reinterpreted for the present case.