A Smart Phone Based Handheld Wireless Spirometer with Functions and Precision Comparable to Laboratory Spirometers

We report a smart phone based handheld wireless spirometer which uses a Lilly type sensing flowhead for respiratory signal acquisition and transmits the data to smartphone or other mobile terminals with Bluetooth signal transmission for data processing and result display. The developed spirometer was demonstrated to be able to detect flow rates ranging from 0–15 L/s with an accuracy of 4 mL/s, and can perform tests of flow volume (FV), forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), peak expiratory flow (PEF), etc. By having the functions and precision comparable to laboratory spirometers, it satisfies the American Thoracic Society and European Respiratory Society (ATS/ERS) proposed performance requirements for spirometer. At the same time, it is low cost, light and handy, low power consumption battery-powered. The test of 12 cases of subjects using the developed spirometer also indicated that it was easy to use for both providers and patients, and suitable for the Point of Care Test (POCT) of chronic obstructive pulmonary disease (COPD) and asthma at general-practice settings and homes.

[1]  R. Crapo,et al.  Instrument accuracy and reproducibility in measurements of pulmonary function. , 2007, Chest.

[2]  M. Laghrouche,et al.  Low-cost Embedded Spirometer Based on Commercial Micro Machined Platinum Thin Film , 2016 .

[3]  K. Wasserman,et al.  Evaluation of a symmetrically disposed Pitot tube flowmeter for measuring gas flow during exercise. , 1994, Journal of applied physiology.

[4]  nbspMs. N.Shivaani Varsha Real Time Monitoring of Respiratory Parameters Using A Wireless Portable System , 2015 .

[5]  W. Jitschin Gas flow measurement by the thin orifice and the classical Venturi tube , 2004 .

[6]  J. Hankinson,et al.  Method to produce American Thoracic Society flow-time waveforms using a mechanical pump. , 1997, The European respiratory journal.

[7]  M. A. Ardekani,et al.  Extrapolation of Calibration Curve of Hot-wire Spirometer Using a Novel Neural Network Based Approach , 2012, Journal of medical signals and sensors.

[8]  Alper Bozkurt,et al.  Wearable wireless sensors for chronic respiratory disease monitoring , 2015, 2015 IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN).

[9]  T. Crabtree,et al.  Office-Based Spirometry: A New Model of Care in Preoperative Assessment for Low-Risk Lung Resections. , 2018, The Annals of thoracic surgery.

[10]  Y. I. Sokol,et al.  Turbine spirometers metrological support , 2016, 2016 International Conference on Electronics and Information Technology (EIT).

[11]  Alessandro Brunelli,et al.  Physiologic evaluation of the patient with lung cancer being considered for resectional surgery: Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. , 2013, Chest.

[12]  J. Hankinson,et al.  Standardisation of spirometry , 2005, European Respiratory Journal.

[13]  A pilot study of hot-wire, ultrasonic and wedge-bellows spirometer inter- and intra-variability , 2017, BMC Research Notes.

[14]  B. M. Wright A miniature Wright peak-flow meter. , 1978, British medical journal.

[15]  D.M. Maree,et al.  Comparison of a New Desktop Spirometer (Diagnosa®) with a Laboratory Spirometer , 2001, Respiration.