A wearable diffuse reflectance sensor for continuous monitoring of cutaneous blood content

An optical diffuse reflectance sensor for characterization of cutaneous blood content and optimized for continuous monitoring has been developed as part of a non-invasive multisensor system for glucose monitoring. A Monte Carlo simulation of the light propagation in the multilayered skin model has been performed in order to estimate the optimal geometrical separation of the light source and detector for skin and underlying tissue. We have observed that the pathlength within the upper vascular plexus of the skin which defines the sensor sensitivity initially grows with increasing source-detector distance (SDD) before reaching a maximum at 3.5 mm and starts to decay with further increase. At the same time, for distances above 2.4 mm, the sensor becomes sensitive to muscle blood content, which decreases the specificity to skin perfusion monitoring. Thus, the SDDs in the range from 1.5 mm to 2.4 mm satisfy the requirements of sensor sensitivity and specificity. The hardware implementation of the system has been realized and tested in laboratory experiments with a venous occlusion procedure and in an outpatient clinical study in 16 patients with type 1 diabetes mellitus. For both testing procedures, the optical sensor demonstrated high sensitivity to perfusion change provoking events. The general build-up of cutaneous blood under the sensor has been observed which can be associated with pressure-induced vasodilation as a response to the sensor application.

[1]  J. Bakker,et al.  Noninvasive monitoring of peripheral perfusion , 2005, Intensive Care Medicine.

[2]  I. V. Meglinsky,et al.  Modelling the sampling volume for skin blood oxygenation measurements , 2006, Medical and Biological Engineering and Computing.

[3]  A. Welch,et al.  A review of the optical properties of biological tissues , 1990 .

[4]  M. Copet,et al.  A Monte Carlo investigation of optical pathlength in inhomogeneous tissue and its application to near-infrared spectroscopy , 1993 .

[5]  Yuri Feldman,et al.  Cell Membrane Response on d-Glucose Studied by Dielectric Spectroscopy. Erythrocyte and Ghost Suspensions , 2004 .

[6]  Valerie C. Scanlon,et al.  Essentials of Anatomy and Physiology , 1991 .

[7]  J M Schmitt,et al.  Optimal probe geometry for near-infrared spectroscopy of biological tissue. , 1997, Applied optics.

[8]  I. V. Meglinskiĭ,et al.  Analysis of the spatial distribution of detector sensitivity in a multilayer randomly inhomogeneous medium with strong light scattering and absorption by the Monte Carlo method , 2001 .

[9]  W. Herman,et al.  Renal assessment practices and the effect of nurse case management of health maintenance organization patients with diabetes. , 1999, Diabetes care.

[10]  W. C. Randall,et al.  Relations between cutaneous blood flow and blood content in the finger pad, forearm, and forehead. , 1947, The American journal of physiology.

[11]  W. Cui,et al.  In vivo reflectance of blood and tissue as a function of light wavelength , 1990, IEEE Transactions on Biomedical Engineering.

[12]  E. Gordy,et al.  Spectrophotometric studies. XVI. Determination of the oxygen saturation of blood by a simplified technique, applicable to standard equipment. , 1957, The Journal of biological chemistry.

[13]  Volker Hietschold,et al.  External compression increases forearm perfusion. , 2005, Journal of applied physiology.

[14]  D. J. Ellis,et al.  A portable reflectometer for the rapid quantification of cutaneous haemoglobin and melanin. , 1988, Physics in medicine and biology.

[15]  I. Meglinski,et al.  Quantitative assessment of skin layers absorption and skin reflectance spectra simulation in the visible and near-infrared spectral regions. , 2002, Physiological measurement.

[16]  Yuri Feldman,et al.  Dielectric spectroscopy study of specific glucose influence on human erythrocyte membranes , 2003 .

[17]  Mark S. Talary,et al.  In vivo life sign application of dielectric spectroscopy and non-invasive glucose monitoring , 2007 .

[18]  T. Gambichler,et al.  In vivo data of epidermal thickness evaluated by optical coherence tomography: effects of age, gender, skin type, and anatomic site. , 2006, Journal of dermatological science.

[19]  S. Arridge,et al.  Estimation of optical pathlength through tissue from direct time of flight measurement , 1988 .

[20]  Lutz Heinemann,et al.  Non-invasive glucose monitoring in patients with Type 1 diabetes: a Multisensor system combining sensors for dielectric and optical characterisation of skin. , 2009, Biosensors & bioelectronics.

[21]  R. Marks,et al.  Portable erythema meter and its application to use in human skin , 1990, International journal of cosmetic science.

[22]  J L Saumet,et al.  Dynamics of local pressure-induced cutaneous vasodilation in the human hand. , 2001, Microvascular research.

[23]  P. Abraham,et al.  Mechanisms of the cutaneous vasodilator response to local external pressure application in rats: involvement of CGRP, neurokinins, prostaglandins and NO , 2000, British journal of pharmacology.

[24]  S. Arridge,et al.  A Monte Carlo investigation of optical pathlength in inhomogeneous tissue and its application to near-infrared spectroscopy. , 1993, Physics in medicine and biology.

[25]  M. Joyner,et al.  Nitric oxide and neurally mediated regulation of skin blood flow during local heating. , 2001, Journal of applied physiology.

[26]  R. Rizza,et al.  Cutaneous vascular function during acute hyperglycemia in healthy young adults. , 2002, Journal of applied physiology.

[27]  E. K. S. Stopps,et al.  Tissue parameters determining the visual appearance of normal skin and port-wine stains , 1995, Lasers in Medical Science.

[28]  A. N. Bashkatov,et al.  Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nm , 2005 .

[29]  P. Abraham,et al.  Impaired pressure-induced vasodilation at the foot in young adults with type 1 diabetes. , 2004, Diabetes.

[30]  S. Silbernagl,et al.  Color atlas of physiology , 1981 .

[31]  L Wang,et al.  MCML--Monte Carlo modeling of light transport in multi-layered tissues. , 1995, Computer methods and programs in biomedicine.

[32]  O. Khalil,et al.  Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. , 2004, Diabetes technology & therapeutics.

[33]  B. Diffey,et al.  A portable instrument for quantifying erythema induced by ultraviolet radiation , 1984, The British journal of dermatology.

[34]  B. Chance,et al.  Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans. , 2007, Journal of biomedical optics.

[35]  Peter Elsner,et al.  Bioengineering of the skin : cutaneous blood flow and erythema , 1995 .

[36]  Yukio Yamada,et al.  Monte Carlo Simulation of Near Infrared Reflectance Spectroscopy in the Wavelength Range from 1000 nm to 1900 nm , 2003 .

[37]  Yukio Yamada,et al.  Depth profile of diffuse reflectance near‐infrared spectroscopy for measurement of water content in skin , 2005, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[38]  O G Edholm,et al.  The effect of temperature on blood flow and deep temperature in the human forearm , 1943, The Journal of physiology.

[39]  Detection Limit of Glucose Concentration with Near-Infrared Absorption and Scattering Spectroscopy , 2008 .

[40]  Lucien F. A. Douven,et al.  Retrieval of optical properties of skin from measurement and modeling the diffuse reflectance , 2000, Photonics West - Biomedical Optics.

[41]  B. Gerdle,et al.  Non-invasive monitoring of muscle blood perfusion by photoplethysmography: evaluation of a new application. , 2005, Acta physiologica Scandinavica.

[42]  Westgate Road,et al.  Photoplethysmography and its application in clinical physiological measurement , 2007 .