Intelligent Failure Diagnosis for Gas Circuit Breakers Based on Dynamic Resistance Measurements

Moving and fixed main and arc contacts used in circuit breakers (CBs) are prone to erosion with time and usage. Static resistance measurement and dynamic resistance measurement (DRM) are well-known noninvasive methods for the condition assessment of the contacts. Practically, the implementation of various failures on contacts of the CB is so difficult due to their placement in a high-pressure interruption chamber. This paper investigates the impacts of common failure modes such as erosion, disconnection, and misalignment of contacts on DRM profile through 3-D multiphysical simulation of the interruption chamber in the finite-element analysis software COMSOL. The model has been verified against experiments conducted on a 24-kV, SF6 CB with a high-resolution scope. The measured profiles indicate that DRM exhibits specific behavior with respect to each failure, e.g., the arc contact erosion leads to a change in the commutation point in DRM. The results have been organized into an intelligent failure diagnosis algorithm based on a set of DRM-based features. In the end, the performance of the proposed algorithm which could be suitable for smart grids is evaluated in the case of an experiment.

[1]  Loredana Cristaldi,et al.  A data-driven prognostic approach based on statistical similarity: An application to industrial circuit breakers , 2017 .

[2]  Abhisek Ukil,et al.  Monitoring of HV Generator Circuit Breaker Contact Ablation Based on Acoustic Emission , 2013, IEEE Transactions on Instrumentation and Measurement.

[3]  Zoran Stanisic Method for static and dynamic resistance measurements of HV circuit breaker , 2011, 2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies.

[4]  Zoran Stanisic,et al.  A new ultra lightweight method for Static and dynamic resistance measurements , 2010, 2010 IEEE International Symposium on Electrical Insulation.

[5]  Anton Janssen,et al.  International Surveys on Circuit-Breaker Reliability Data for Substation and System Studies , 2014, IEEE Transactions on Power Delivery.

[6]  Jing-gang Yang,et al.  The Mathematical Model of Contact Resistance and Injected Current in DRM Tests of SF6 Circuit Breaker , 2018, IEEE Transactions on Components, Packaging and Manufacturing Technology.

[7]  A. Mercier,et al.  A New Measurement Method of the Dynamic Contact Resistance of HV Circuit Breakers , 2006, 2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition.

[8]  L. Lan,et al.  Electrical erosion test and condition assessment of SF6 CB contact sets , 2017 .

[9]  Asghar Bagherpoor,et al.  Online Condition Assessment of Interruption Chamber of Gas Circuit Breakers Using Arc Voltage Measurement , 2017, IEEE Transactions on Power Delivery.

[10]  Ali Asghar Razi-Kazemi,et al.  A novel high-frequency-based diagnostic approach for main contact assessment of high voltage circuit breakers , 2017 .

[11]  W. Z. Gandhare,et al.  An Overview of Dynamic Contact Resistance Measurement of HV Circuit Breakers , 2016 .

[12]  R. Garzon High Voltage Circuit Breakers : Design and Applications , 2002 .

[13]  M. Landry,et al.  A Complete Strategy for Conducting Dynamic Contact Resistance Measurements on HV Circuit Breakers , 2008, IEEE Transactions on Power Delivery.

[14]  J. Paulke,et al.  Thermal simulation of switchgear , 2001, Proceedings of the Forth-Seventh IEEE Holm Conference on Electrical Contacts (IEEE Cat. No.01CH37192).

[15]  Ali Asghar Razi-Kazemi,et al.  Condition assessment of arc contacts through dynamic resistance measurement (DRM) and wavelet analysis , 2017, 2017 Iranian Conference on Electrical Engineering (ICEE).

[16]  Fan Yang,et al.  Support vector machine with genetic algorithm for machinery fault diagnosis of high voltage circuit breaker , 2011 .