Radiation dosimetry in digital breast tomosynthesis: report of AAPM Tomosynthesis Subcommittee Task Group 223.
暂无分享,去创建一个
Ioannis Sechopoulos | Andrew D. A. Maidment | Anita Nosratieh | Kazuyoshi Nishino | Baorui Ren | W Paul Segars | Mitchell Goodsitt | John M. Sabol | William Geiser | Joseph Y Lo | Wesley E Bolch | Andrew D A Maidment | Emmanuel Christodoulou | Michael Flynn | John M Sabol | Libby Brateman | J. Lo | W. Segars | M. Goodsitt | I. Sechopoulos | A. Nosratieh | A. Jones | W. Bolch | M. Flynn | E. Christodoulou | A Kyle Jones | L. Brateman | K. Nishino | Johan Berglund | Miriam Von Tiedemann | W. Geiser | B. Ren | M. von Tiedemann | Johan Berglund
[1] J. Boone. Normalized glandular dose (DgN) coefficients for arbitrary X-ray spectra in mammography: computer-fit values of Monte Carlo derived data. , 2002, Medical physics.
[2] C. D'Orsi,et al. Computation of the glandular radiation dose in digital tomosynthesis of the breast. , 2006, Medical physics.
[3] D. Dance. Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose. , 1990, Physics in medicine and biology.
[4] E. W. Shrigley. Medical Physics , 1944, British medical journal.
[5] J. S. Laughlin,et al. Absorbed radiation dose in mammography. , 1979, Radiology.
[6] Carl J. D'Orsi,et al. Glandular radiation dose in tomosynthesis of the breast using tungsten targets , 2008, Journal of applied clinical medical physics.
[7] I. Sechopoulos,et al. Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry. , 2012, Medical physics.
[8] L. Kochian. Author to whom correspondence should be addressed , 2006 .
[9] G. Barnes,et al. Spectral dependence of glandular tissue dose in screen-film mammography. , 1991, Radiology.
[10] D. Dance,et al. Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols , 2011, Physics in medicine and biology.
[11] J. Boone,et al. Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment. , 1999, Radiology.
[12] I. Sechopoulos. A review of breast tomosynthesis. Part I. The image acquisition process. , 2013, Medical physics.
[13] Spencer Gunn,et al. Mean glandular dose estimation using MCNPX for a digital breast tomosynthesis system with tungsten/aluminum and tungsten/aluminum+silver x-ray anode-filter combinations. , 2008, Medical physics.
[14] W. Sobol,et al. Parametrization of mammography normalized average glandular dose tables. , 1997, Medical physics.
[15] S. Incerti,et al. Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.
[16] G. Barnes,et al. Normalized average glandular dose in molybdenum target-rhodium filter and rhodium target-rhodium filter mammography. , 1994, Radiology.
[17] T. Koi,et al. Geant 4 Developments and Applications , 2013 .
[18] C. J. Kotre,et al. Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol. , 2000, Physics in medicine and biology.
[19] Edward F. Bullard,et al. Mean glandular dose estimation using MCNPX for a digital breast tomosynthesis system with tungsten/aluminum and tungsten/aluminum+silver x-ray anode-filter combinations. , 2008, Medical physics.
[20] D R Dance,et al. The Monte Carlo calculation of integral radiation dose in xeromammography , 1980, Physics in medicine and biology.
[21] Andrew D. A. Maidment,et al. Breast dosimetry using high-resolution voxel phantoms. , 2005, Radiation protection dosimetry.
[22] T. R. Fewell,et al. Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. , 1997, Medical physics.