Effect of wind parks with doubly fed asynchronous generators on small-signal stability

This paper investigates modes of response introduced by wind parks with doubly fed asynchronous generators (DFAGs), as well as their impact on electromechanical oscillations in interconnected power systems. A DFAG model with detailed control loops is used, as it appears in the literature and commercial software. It is shown that under certain conditions and without appropriate controller tuning the voltage/VAR control loop of an interconnected DFAG tends to instability. Furthermore, the effect of increased penetration of DFAGs on the stability of inter-area oscillations in a small typical power system is examined. It is shown that the effect is generally favorable, but there are cases where the inter-area mode is less damped or can even be destabilized. Improved controller tuning to avoid instability in the latter case is proposed.

[1]  P. Kundur,et al.  Power system stability and control , 1994 .

[2]  Janaka Ekanayake,et al.  Dynamic modeling of doubly fed induction generator wind turbines , 2003 .

[3]  C.D. Vournas,et al.  An educational simulation tool for power system control and stability , 2004, IEEE Transactions on Power Systems.

[4]  Graham Rogers,et al.  Power System Oscillations , 1999 .

[5]  P. Ledesma,et al.  Doubly fed induction generator model for transient stability analysis , 2005, IEEE Transactions on Energy Conversion.

[6]  O. Anaya-Lara,et al.  A power system stabilizer for DFIG-based wind generation , 2006, IEEE Transactions on Power Systems.

[7]  Ricardo J. Mantz,et al.  Impact of wind farms on a power system. An eigenvalue analysis approach , 2007 .

[8]  Xiao-Ping Zhang,et al.  Small signal stability analysis and optimal control of a wind turbine with doubly fed induction generator , 2007 .

[9]  Henk Polinder,et al.  Dynamic modelling of a wind turbine with doubly fed induction generator , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[10]  E. Muljadi,et al.  Effect of Variable Speed Wind Turbine Generator on Stability of a Weak Grid , 2007, IEEE Transactions on Energy Conversion.

[11]  Kjetil Uhlen,et al.  Large‐scale wind power integration in Norway and impact on damping in the Nordic grid , 2005 .

[12]  M. Kayikci,et al.  Reactive Power Control Strategies for DFIG-Based Plants , 2007, IEEE Transactions on Energy Conversion.

[13]  I. Erlich,et al.  Modeling of Wind Turbines Based on Doubly-Fed Induction Generators for Power System Stability Studies , 2007, IEEE Transactions on Power Systems.

[14]  N.W. Miller,et al.  Dynamic modeling of GE 1.5 and 3.6 MW wind turbine-generators for stability simulations , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[15]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[16]  M. A. Poller Doubly-fed induction machine models for stability assessment of wind farms , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[17]  N. Mohan,et al.  Control of a Doubly Fed Induction Wind Generator Under Unbalanced Grid Voltage Conditions , 2007, IEEE Transactions on Energy Conversion.

[18]  Bikash C. Pal,et al.  Modal Analysis of Grid-Connected Doubly Fed Induction Generators , 2007 .

[19]  Yixin Ni,et al.  Modelling analysis of transient stability simulation with high penetration of grid‐connected wind farms of DFIG type , 2007 .

[20]  A. Mullane,et al.  Modeling of the wind turbine with a doubly fed induction generator for grid integration studies , 2006, IEEE Transactions on Energy Conversion.

[21]  J.J. Sanchez-Gasca,et al.  A modal analysis of a two-area system with significant wind power penetration , 2004, IEEE PES Power Systems Conference and Exposition, 2004..

[22]  R. Blasco-Gimenez,et al.  Control of Offshore DFIG-Based Wind Farm Grid With Line-Commutated HVDC Connection , 2007, IEEE Transactions on Energy Conversion.

[23]  J. G. Slootweg,et al.  The impact of large scale wind power generation on power system oscillations , 2003 .

[24]  H. Banakar,et al.  Steady-state stability analysis of doubly-fed induction generators under decoupled P–Q control , 2006 .

[25]  Olimpo Anaya-Lara,et al.  Rotor flux magnitude and angle control strategy for doubly fed induction generators , 2006 .

[26]  Hans Knudsen,et al.  An aggregate model of a grid-connected, large-scale, offshore wind farm for power stability investigations—importance of windmill mechanical system , 2002 .