Improved perfusion‐weighted MRI by a novel double inversion with proximal labeling of both tagged and control acquisitions

A novel pulsed arterial spin labeling (PASL) technique for multislice perfusion‐weighted imaging is proposed that compensates for magnetization transfer (MT) effects without sacrificing tag efficiency, and balances transient magnetic field effects (eddy currents) induced by pulsed field gradients. Improved compensation for MT is demonstrated using a phantom. Improvement in perfusion measurement was compared to other PASL techniques by acquiring perfusion images from 13 healthy volunteers (nine women and four men; age range 29–64 years; mean age 45 ± 14 years) and second‐order image texture analysis. The main improvements with the new method were significantly higher image contrast, higher mean signal intensity, and better signal uniformity across slices. In conclusion, this new PASL method should provide improved accuracy in measuring brain perfusion. Magn Reson Med 49:307–314, 2003. © 2003 Wiley‐Liss, Inc.

[1]  Robert M. Haralick,et al.  Textural Features for Image Classification , 1973, IEEE Trans. Syst. Man Cybern..

[2]  W. J. Lorenz,et al.  Diagnostic accuracy of computerized B‐scan texture analysis and conventional ultrasonography in diffuse parenchymal and malignant liver disease , 1985, Journal of clinical ultrasound : JCU.

[3]  M. Bucciolini,et al.  Relaxation rates of paramagnetic solutions: evaluation by nuclear magnetic resonance imaging. , 1986, Medical physics.

[4]  J. Ross,et al.  Three-dimensional FLASH imaging: applications with gadolinium-DTPA. , 1989, Journal of computer assisted tomography.

[5]  D. S. Williams,et al.  Magnetic resonance imaging of perfusion using spin inversion of arterial water. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[6]  A. Nobre,et al.  Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency. , 1994, Radiology.

[7]  G B Matson,et al.  An integrated program for amplitude-modulated RF pulse generation and re-mapping with shaped gradients. , 1994, Magnetic resonance imaging.

[8]  T. L. Davis,et al.  Mr perfusion studies with t1‐weighted echo planar imaging , 1995, Magnetic resonance in medicine.

[9]  Seong-Gi Kim Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping , 1995, Magnetic resonance in medicine.

[10]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.

[11]  R. Sperling,et al.  Noninvasive perfusion MRI in Alzheimer's disease , 1996, Neurology.

[12]  J A Frank,et al.  Perfusion imaging with compensation for asymmetric magnetization transfer effects , 1996, Magnetic resonance in medicine.

[13]  R B Buxton,et al.  Slice profile effects in adiabatic inversion: Application to multislice perfusion imaging , 1997, Magnetic resonance in medicine.

[14]  W. Jagust,et al.  Clinical Studies of Cerebral Blood Flow in Alzheimer's Disease , 1997, Annals of the New York Academy of Sciences.

[15]  R. Buxton,et al.  Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling , 1997, NMR in biomedicine.

[16]  R R Edelman,et al.  EPISTAR MRI: Multislice mapping of cerebral blood flow , 1998, Magnetic resonance in medicine.

[17]  J. Detre,et al.  Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease , 1998, Neurology.

[18]  J. H. Duyn,et al.  Multislice Imaging of Quantitative Cerebral Perfusion with Pulsed Arterial Spin-Labeling , 1998, NeuroImage.

[19]  R B Buxton,et al.  A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging , 1998, Magnetic resonance in medicine.

[20]  P. Bandettini,et al.  QUIPSS II with thin‐slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling , 1999, Magnetic resonance in medicine.

[21]  H. Lei,et al.  A strategy to optimize the signal‐to‐noise ratio in one‐coil arterial spin tagging perfusion imaging , 1999, Magnetic resonance in medicine.

[22]  P. Boesiger,et al.  Transfer insensitive labeling technique (TILT): Application to multislice functional perfusion imaging , 1999, Journal of magnetic resonance imaging : JMRI.

[23]  J L Tanabe,et al.  MR perfusion imaging in human brain using the UNFAIR technique , 1999, Journal of magnetic resonance imaging : JMRI.

[24]  J. Detre,et al.  Assessment of cerebral blood flow in Alzheimer's disease by spin‐labeled magnetic resonance imaging , 2000, Annals of neurology.

[25]  D. Weinberger,et al.  Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST) , 2000, Magnetic resonance in medicine.

[26]  J. Duyn,et al.  High‐sensitivity single‐shot perfusion‐weighted fMRI † , 2001, Magnetic resonance in medicine.

[27]  G. Jahng,et al.  FAIR exempting separate T 1 measurement (FAIREST): a novel technique for online quantitative perfusion imaging and multi‐contrast fMRI , 2001, NMR in biomedicine.

[28]  J. Knight‐Scott,et al.  Theoretical analysis of the effect of imperfect slice profiles on tagging schemes for pulsed arterial spin labeling MRI , 2001, Magnetic resonance in medicine.