Upper limb joint angle measurement in occupational health

Usual human motion capture systems are designed to work in controlled laboratory conditions. For occupational health, instruments that can measure during normal daily life are essential, as the evaluation of the workers' movements is a key factor to reduce employee injury- and illness-related costs. In this paper, we present a method for joint angle measurement, combining inertial sensors (accelerometers and gyroscopes) and magnetic sensors. This method estimates wrist flexion, wrist lateral deviation, elbow flexion, elbow pronation, shoulder flexion, shoulder abduction and shoulder internal rotation. The algorithms avoid numerical integration of the signals, which allows for long-time estimations without angle estimation drift. The system has been tested both under laboratory and field conditions. Controlled laboratory tests show mean estimation errors between 0.06° and of 1.05°, and standard deviation between 2.18° and 9.20°. Field tests seem to confirm these results when no ferromagnetic materials are close to the measurement system.

[1]  Enrique J. Gómez,et al.  Upper Limb Portable Motion Analysis System Based on Inertial Technology for Neurorehabilitation Purposes , 2010, Sensors.

[2]  S. O’Driscoll,et al.  Accuracy and inter-observer reliability of visual estimation compared to clinical goniometry of the elbow , 2012, Knee Surgery, Sports Traumatology, Arthroscopy.

[3]  Daniel Tik-Pui Fong,et al.  The Use of Wearable Inertial Motion Sensors in Human Lower Limb Biomechanics Studies: A Systematic Review , 2010, Sensors.

[4]  Huosheng Hu,et al.  Reducing Drifts in the Inertial Measurements of Wrist and Elbow Positions , 2010, IEEE Transactions on Instrumentation and Measurement.

[6]  M H Granat,et al.  A practical gait analysis system using gyroscopes. , 1999, Medical engineering & physics.

[7]  Peter H Veltink,et al.  Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems. , 2002, Journal of biomechanics.

[8]  Roman Kamnik,et al.  An inertial and magnetic sensor based technique for joint angle measurement. , 2007, Journal of biomechanics.

[9]  Yeh-Liang Hsu,et al.  A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring , 2010, Sensors.

[10]  Peng Cheng,et al.  Joint-Angle Measurement Using Accelerometers and Gyroscopes—A Survey , 2010, IEEE Transactions on Instrumentation and Measurement.

[11]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[12]  Kamiar Aminian,et al.  A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes , 2005, IEEE Transactions on Biomedical Engineering.

[13]  James McNames,et al.  Shoulder and Elbow Joint Angle Tracking With Inertial Sensors , 2012, IEEE Transactions on Biomedical Engineering.

[14]  Satoshi Kurata,et al.  Joint motion monitoring by accelerometers set at both near sides around the joint , 1998, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286).