Optimal Current Meter Placement for Accurate Fault Location Purpose using Dynamic Time Warping

This paper presents a fault location technique for transmission lines with minimum current measurement. This algorithm investigates proper current ratios for fault location problem based on thevenin theory in faulty power networks and calculation of short circuit currents in each branch. These current ratios are extracted regarding lowest sensitivity on thevenin impedance variations of the network structure. Proposed algorithm compares current ratios from offline calculations with corresponding values achieved from measurements with a look-up table system. Best solution based on Dynamic Time Warping (DTW) algorithm is introduced as an output (location of the fault) which includes the line and the distance. Among many current ratios to form look-up table system, the minimum number of them will be extracted by a multi-objective optimization technique using Bees Algorithm (BA). This extraction is based on lowest possible number of buses for instruments installation and required current measurements, estimation accuracy and sensitivity degree from thevenin impedances changes. Accuracy of proposed algorithm is evaluated in a widely used multi-machine network of Western Systems Coordinating Council (WSCC).

[1]  Y.J. Xia,et al.  A novel fault location scheme using voltage traveling-wave of CVTs , 2004, 39th International Universities Power Engineering Conference, 2004. UPEC 2004..

[2]  Witold Pedrycz,et al.  Knowledge-based clustering - from data to information granules , 2007 .

[4]  A. Sauhats,et al.  Fault location algorithms for super high voltage power transmission lines , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[5]  Xiao-Ping Zhang,et al.  Coordinated algorithms for distributed state estimation with synchronized phasor measurements , 2012 .

[6]  Rajat Saini,et al.  OPTIMAL PLACEMENT OF PHASOR MEASUREMENT UNITS FOR POWER SYSTEM OBSERVABILITY , 2013 .

[7]  Ying-Hong Lin,et al.  An adaptive PMU based fault detection/location technique for transmission lines. I. Theory and algorithms , 2000 .

[8]  A.G. Phadke,et al.  Phasor measurement unit placement techniques for complete and incomplete observability , 2005, IEEE Transactions on Power Delivery.

[9]  A. A. Fahmy Using the Bees Algorithm to select the optimal speed parameters for wind turbine generators , 2012, J. King Saud Univ. Comput. Inf. Sci..

[10]  J.-A. Jiang,et al.  Transmission network fault location observability with minimal PMU placement , 2006, IEEE Transactions on Power Delivery.

[11]  T. Seeley The Wisdom of the Hive: The Social Physiology of Honey Bee Colonies , 1995 .

[12]  Ying-Hong Lin,et al.  An adaptive PMU based fault detection/location technique for transmission lines. II. PMU implementation and performance evaluation , 2000 .

[13]  S.H.H. Sadeghi,et al.  Determination of optimal PMU placement for fault-location observability , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[14]  S.S. Geramian,et al.  Determination of optimal PMU placement for fault location using genetic algorithm , 2008, 2008 13th International Conference on Harmonics and Quality of Power.

[15]  Babak Mozafari,et al.  Optimal placement of PMUs to maintain network observability using a modified BPSO algorithm , 2011 .

[16]  A. Zehtabian,et al.  A Non-destructive Approach for Noise Reduction in Time Domain , 2009 .

[17]  S.M. Brahma,et al.  Fault location scheme for a multi-terminal transmission line using synchronized Voltage measurements , 2005, IEEE Transactions on Power Delivery.

[18]  Y. Alinejad-Beromi,et al.  Optimal PMU placement for power system observability using binary particle swarm optimization and considering measurement redundancy , 2011, Expert Syst. Appl..

[19]  D. Pham,et al.  THE BEES ALGORITHM, A NOVEL TOOL FOR COMPLEX OPTIMISATION PROBLEMS , 2006 .

[20]  Seung-Il Moon,et al.  Optimal number and locations of power quality monitors considering system topology , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[21]  E.F. El-Saadany,et al.  A novel power quality monitoring allocation algorithm , 2006, IEEE Transactions on Power Delivery.

[22]  Sukumar Brahma,et al.  Optimal PMU placement for fault location in a power system , 2009, 41st North American Power Symposium.

[23]  P. Bastard,et al.  A voltage-based fault location method for radial distribution networks , 2002 .

[24]  Rahmat-Allah Hooshmand,et al.  A new method for optimal placement of phasor measurement units to maintain full network observability under various contingencies , 2012 .

[25]  Meinard Müller,et al.  Information retrieval for music and motion , 2007 .

[26]  L.C. Zanetta,et al.  Fault location in transmission lines using one-terminal postfault voltage data , 2004, IEEE Transactions on Power Delivery.

[27]  A.A. Girgis,et al.  Fault location on a transmission line using synchronized Voltage measurements , 2004, IEEE Transactions on Power Delivery.

[28]  Seema Singh,et al.  Optimal PMU placement method for complete topological and numerical observability of power system , 2010 .

[29]  A. Abur,et al.  Fault Location Using Voltage Measurements , 2001, IEEE Power Engineering Review.

[30]  Zhang Yi,et al.  Fault location method based on the periodicity of the transient voltage traveling wave , 2004, 2004 IEEE Region 10 Conference TENCON 2004..

[31]  M. Shahidehpour,et al.  Contingency-Constrained PMU Placement in Power Networks , 2010, IEEE Transactions on Power Systems.

[32]  Duc Truong Pham,et al.  The Bees Algorithm: Modelling foraging behaviour to solve continuous optimization problems , 2009 .

[33]  A. Sheikholeslami,et al.  A current independent method based on synchronized voltage measurement for fault location on transmission lines , 2009, Simul. Model. Pract. Theory.

[34]  S.M. Brahma New fault-location method for a single multiterminal transmission line using synchronized phasor measurements , 2006, IEEE Transactions on Power Delivery.

[35]  Pavel Senin,et al.  Dynamic Time Warping Algorithm Review , 2008 .

[36]  Demetrios G. Eliades,et al.  Placement of Synchronized Measurements for Power System Observability , 2009, IEEE Transactions on Power Delivery.

[37]  A. Abur,et al.  Observability analysis and measurement placement for systems with PMUs , 2004, IEEE PES Power Systems Conference and Exposition, 2004..

[38]  A. Abur,et al.  Placement of PMUs to Enable Bad Data Detection in State Estimation , 2006, IEEE Transactions on Power Systems.