3D dynamic MRI of the vocal tract during natural speech
暂无分享,去创建一个
Shrikanth Narayanan | Shrikanth S. Narayanan | Dani Byrd | Sajan Goud Lingala | Yinghua Zhu | Yongwan Lim | Krishna Shrinivas Nayak | K. Nayak | D. Byrd | Yinghua Zhu | S. Lingala | Yongwan Lim
[1] Marzena Wylezinska,et al. Speech MRI: morphology and function. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.
[2] Khalil Iskarous,et al. Patterns of tongue movement , 2005, J. Phonetics.
[3] Osamu Fujimura,et al. Allophonic variation in English /l/ and its implications for phonetic implementation , 1993 .
[4] R. Boubertakh,et al. Towards clinical assessment of velopharyngeal closure using MRI: evaluation of real-time MRI sequences at 1.5 and 3 T. , 2012, The British journal of radiology.
[5] J.M. Santos,et al. Flexible real-time magnetic resonance imaging framework , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[6] Shrikanth Narayanan,et al. Feasibility of through‐time spiral generalized autocalibrating partial parallel acquisition for low latency accelerated real‐time MRI of speech , 2017, Magnetic resonance in medicine.
[7] Shrikanth S. Narayanan,et al. Toward automatic vocal tract area function estimation from accelerated three-dimensional magnetic resonance imaging , 2013 .
[8] Shrikanth S. Narayanan,et al. Enhanced airway-tissue boundary segmentation for real-time magnetic resonance imaging data , 2014 .
[9] Shrikanth Narayanan,et al. Synchronized and noise-robust audio recordings during realtime magnetic resonance imaging scans. , 2006, The Journal of the Acoustical Society of America.
[10] Shrikanth S. Narayanan,et al. Analysis of speech production real-time MRI , 2018, Comput. Speech Lang..
[11] Shrikanth S. Narayanan,et al. Faster 3d vocal tract real-time MRI using constrained reconstruction , 2013, INTERSPEECH.
[12] M H Cohen,et al. Electromagnetic midsagittal articulometer systems for transducing speech articulatory movements. , 1992, The Journal of the Acoustical Society of America.
[13] Shrikanth S. Narayanan,et al. State-of-the-Art MRI Protocol for Comprehensive Assessment of Vocal Tract Structure and Function , 2016, INTERSPEECH.
[14] A. Alwan,et al. Toward articulatory-acoustic models for liquid approximants based on MRI and EPG data. Part I. The laterals. , 1997, The Journal of the Acoustical Society of America.
[15] Shrikanth S Narayanan,et al. Dynamic off‐resonance correction for spiral real‐time MRI of speech , 2019, Magnetic resonance in medicine.
[16] Tabea V Flügge,et al. Relevance of the Implementation of Teeth in Three-Dimensional Vocal Tract Models. , 2017, Journal of speech, language, and hearing research : JSLHR.
[17] Shrikanth S. Narayanan,et al. Vocal tract cross-distance estimation from real-time MRI using region-of-interest analysis , 2013, INTERSPEECH.
[18] Shrikanth S. Narayanan,et al. Geometry, kinematics, and acoustics of Tamil liquid consonants. , 1999, The Journal of the Acoustical Society of America.
[19] Michael Elad,et al. ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA , 2014, Magnetic resonance in medicine.
[20] Bruce Denby,et al. Speech synthesis from real time ultrasound images of the tongue , 2004, 2004 IEEE International Conference on Acoustics, Speech, and Signal Processing.
[21] Ravi Seethamraju,et al. Faster dynamic imaging of speech with field inhomogeneity corrected spiral fast low angle shot (FLASH) at 3 T , 2010, Journal of magnetic resonance imaging : JMRI.
[22] Pierre Delattre. CONSONANT GEMINATION IN FOUR LANGUAGES: AN ACOUSTIC, PERCEPTUAL, AND RADIOGRAPHIC STUDY PART I , 1971 .
[23] António J. S. Teixeira,et al. European Portuguese MRI based speech production studies , 2008, Speech Commun..
[24] Zhi-Pei Liang,et al. High‐frame‐rate full‐vocal‐tract 3D dynamic speech imaging , 2017, Magnetic resonance in medicine.
[25] J R Westbury,et al. The significance and measurement of head position during speech production experiments using the x-ray microbeam system. , 1991, The Journal of the Acoustical Society of America.
[26] Shrikanth Narayanan,et al. Test-retest repeatability of human speech biomarkers from static and real-time dynamic magnetic resonance imaging. , 2017, The Journal of the Acoustical Society of America.
[27] Shrikanth S. Narayanan,et al. Flexible retrospective selection of temporal resolution in real‐time speech MRI using a golden‐ratio spiral view order , 2011, Magnetic resonance in medicine.
[28] Maureen C. Stone. Toward a model of three-dimensional tongue movement , 1991 .
[29] Shrikanth S. Narayanan,et al. Estimation of vocal tract area function from volumetric Magnetic Resonance Imaging , 2017, 2017 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).
[30] E. Hoffman,et al. Vocal tract area functions from magnetic resonance imaging. , 1996, The Journal of the Acoustical Society of America.
[31] Zhi-Pei Liang,et al. High-resolution dynamic speech imaging with deformation estimation , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).
[32] Shrikanth Narayanan,et al. A fast and flexible MRI system for the study of dynamic vocal tract shaping , 2017, Magnetic resonance in medicine.
[33] Shrikanth S. Narayanan,et al. Improved imaging of lingual articulation using real‐time multislice MRI , 2012, Journal of magnetic resonance imaging : JMRI.
[34] Yoon-Chul Kim,et al. Seeing speech: Capturing vocal tract shaping using real-time magnetic resonance imaging [Exploratory DSP] , 2008, IEEE Signal Processing Magazine.
[35] B. Hargreaves,et al. Variable‐rate selective excitation for rapid MRI sequences , 2004, Magnetic resonance in medicine.
[36] Shrikanth Narayanan,et al. Acoustic Denoising Using Dictionary Learning With Spectral and Temporal Regularization , 2018, IEEE/ACM Transactions on Audio, Speech, and Language Processing.
[37] Marc E Miquel,et al. Recommendations for real‐time speech MRI , 2016, Journal of magnetic resonance imaging : JMRI.
[38] Jens Frahm,et al. Real‐time MRI of speaking at a resolution of 33 ms: Undersampled radial FLASH with nonlinear inverse reconstruction , 2013, Magnetic resonance in medicine.
[39] Shrikanth Narayanan,et al. An approach to real-time magnetic resonance imaging for speech production. , 2003, The Journal of the Acoustical Society of America.
[40] Maxim Zaitsev,et al. One‐second MRI of a three‐dimensional vocal tract to measure dynamic articulator modifications , 2017, Journal of magnetic resonance imaging : JMRI.
[41] Shrikanth S. Narayanan,et al. Dynamic 3-D Visualization of Vocal Tract Shaping During Speech , 2013, IEEE Transactions on Medical Imaging.
[42] Athanasios Katsamanis,et al. Direct Estimation of Articulatory Kinematics from Real-Time Magnetic Resonance Image Sequences , 2011, INTERSPEECH.
[43] Shrikanth S. Narayanan,et al. Novel 16‐channel receive coil array for accelerated upper airway MRI at 3 Tesla , 2011, Magnetic resonance in medicine.
[44] J. Pauly,et al. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]. , 1991, IEEE transactions on medical imaging.