Synchronized phasor measurements of a power system event in eastern Denmark

Two sets of synchronized phasor measurements 200km apart have been performed during a planned outage of a double 400-kV tie-line between Eastern Denmark and Southern Sweden. The interconnection between Eastern Denmark and Southern Sweden is comprised of a double 400-kV line and a double 132-kV line. The outage of the 400-kV tie-line weakened the Eastern Danish power system and excited power oscillations in the interconnected power systems. During this event prototype, phasor measurements units gave the opportunity of real-time monitoring of positive sequence voltage and current phasors using the satellite-based global positioning system. Comparisons between real-time recordings and results from dynamic simulations with Power System Simulator for Engineering are presented. The main features from the simulation analysis are successfully verified by means of the corresponding synchronized phasor measurements.

[1]  P. Kundur,et al.  Power system stability and control , 1994 .

[2]  Bo Eliasson,et al.  Damping of Power Oscillations in Large Power Systems , 1990 .

[3]  Arne Hejde Nielsen,et al.  Estimation of electro-mechanical mode parameters using frequency measurements , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[4]  V. Vittal,et al.  Solutions for the Crisis in Electric Power Supply Solutions for the Crisis in Electric Power Supply , 2001 .

[5]  A.G. Phadke,et al.  Synchronized phasor measurements in power systems , 1993, IEEE Computer Applications in Power.

[6]  Olof Samuelsson,et al.  An experimental GPS-based phasor measurement unit , 2002 .

[7]  Peter Crossley,et al.  System Protection Schemes in Power Networks , 2001 .

[8]  Morten Hemmingsson Power System Oscillations - Detection, Estimation and Control , 2003 .

[9]  O. Samuelsson Wide Area Measurements of Power System Dynamics - The North American WAMS Project and its Applicability to the Nordic Countries , 2000 .

[10]  T. W. Cease,et al.  Synchronized phasor measurements of a power system event , 1994 .

[11]  John Ballance,et al.  Use of Synchronized Phasor measurement System for Enhancing AC-DC Power System Transmission Reliability and Capability , 2004 .

[12]  H. H. Happ,et al.  Power System Control and Stability , 1979, IEEE Transactions on Systems, Man, and Cybernetics.

[13]  G. Benmouyal,et al.  Synchronized phasor measurement in protective relays for protection, control, and analysis of electric power systems , 2004, 57th Annual Conference for Protective Relay Engineers, 2004.

[14]  K. Uhlen,et al.  Application of linear analysis for stability improvements in the Nordic power transmission system , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).