Comparison of a cathode-ray-tube and film for display of computed radiographic images.

The goal of the study was to compare a cathode-ray-tube (CRT) digital display with film by using task-dependent image quality assessment methods. Contrast-detail analysis was utilized. Human observers performed a simple detection task, specifically, detecting a pillbox target in a uniform Poisson field, using either film or a digital display that employed a CRT monitor. Observers performed equally well on both film and CRT when the window settings of the digital display were established subjectively by a radiologist. Changing the window settings of the digital display to match the average background luminance of a film-illuminator combination decreased the luminance contrast of the targets and observer performance was reduced, though these effects were probably not linked. The "gold standard" film had lower luminance contrast than the CRT displayed images, yet observer performance was never lower for film than for the CRT. Therefore we concluded that luminance contrast was not a limiting factor for observer performance in this study. The CRT monitor changed fairly rapidly after it was calibrated. During a period of six months the gamma of the display increased from 1.82 to 2.42 and the maximum luminance decreased from 319 to 228 cd/m2. Low luminance output demonstrated a larger percentage decrease (approximately equal to 85%) than high luminance output (approximately equal to 29%) over the same time period. These observations suggest that standard window settings should be reviewed from time to time to ensure that the display is used optimally. No special look-up table setup such as perceptual linearization was used.

[1]  P S Rezentes,et al.  The relationship between pixel value and beam quality in photostimulable phosphor imaging. , 1997, Medical physics.

[2]  John A. Swets,et al.  Evaluation of diagnostic systems : methods from signal detection theory , 1982 .

[3]  C A Britton,et al.  Digital radiography and conventional imaging of the chest: a comparison of observer performance. , 1994, AJR. American journal of roentgenology.

[4]  Hans M. Mosser,et al.  Clinical routine operation of a filmless radiology department: three years experience , 1995, Medical Imaging.

[5]  Hartwig R. Blume,et al.  Display of medical images on CRT soft-copy displays: a tutorial , 1995, Medical Imaging.

[6]  J. Swets Indices of discrimination or diagnostic accuracy: their ROCs and implied models. , 1986, Psychological bulletin.

[7]  Michael J. Flynn,et al.  Flat panel display technology for high-performance radiographic imaging , 1995, Medical Imaging.

[8]  D A Bluemke,et al.  Interpretation of emergency department radiographs by radiologists and emergency medicine physicians: teleradiology workstation versus radiograph readings. , 1995, Radiology.

[9]  G G Cox,et al.  Comparison of the low-contrast detectability of a screen-film system and third generation computed radiography. , 1994, Medical physics.

[10]  D Magid,et al.  Subtle orthopedic fractures: teleradiology workstation versus film interpretation. , 1993, Radiology.

[11]  C. Metz ROC Methodology in Radiologic Imaging , 1986, Investigative radiology.

[12]  F A DiBianca,et al.  The Use of Contrast‐Detail‐Dose Evaluation of Image Quality in a Computed Tomographic Scanner , 1979, Journal of computer assisted tomography.

[13]  M P Capp,et al.  Receiver Operating Characteristic Evaluation of Computer Display of Adult Portable Chest Radiographs , 1994, Investigative radiology.

[14]  Suzy Smith,et al.  Lessons learned and two years clinical experience in implementing the Medical Diagnostic Imaging Support (MDIS) System at Madigan Army Medical Center , 1994, Medical Imaging.

[15]  H Fujita,et al.  Basic imaging properties of a computed radiographic system with photostimulable phosphors. , 1989, Medical physics.

[16]  R. F. Wagner,et al.  Absolute measures of physical image quality: measurement and application to radiographic magnification. , 1982, Medical physics.

[17]  C. Flagle,et al.  Receiver operating characteristic analysis of fracture and pneumonia detection: comparison of laser-digitized workstation images and conventional analog radiographs. , 1993, Radiology.

[18]  R. F. Wagner,et al.  Unified SNR analysis of medical imaging systems , 1985, Physics in medicine and biology.

[19]  G G Cox,et al.  Contrast-detail analysis of image degradation due to lossy compression. , 1995, Medical physics.