A neural recording amplifier based on adaptive SNR optimization technique for long-term implantation

Long-term neural recording which can consistently provide good signal-to-noise ratio (SNR) performance over time is important for stable operation of neuroprosthetic systems. This paper presents an analysis for the SNR optimization in a changing environment which causes variations in the tissue-electrode impedance, Zte. Based on the analysis result, a neural recording amplifier (NRA) is developed employing the SNR optimization technique. The NRA can adaptively change its configuration for in situ SNR optimization. The SNR is improved by 4.69% to 23.33% as Zte changes from 1.59 MQ to 31.8 MQ at 1 kHz. The NRA is fabricated in a 0.18-μm standard CMOS process and operates at 1.8-V supply while consuming 1.6 μA It achieves an input-referred noise of 4.67 μVrms when integrated from 1 Hz to 10 kHz, which leads to the NEF of 2.27 and the NEF2VDD of 9.28. The frequency reponse is measured with a high-pass cutoff frequency of 1 Hz and a low-pass cutoff frequency of 10 kHz. The midband gain is set to 40 dB while occupying 0.11 mm2 of a chip area.

[1]  Minkyu Je,et al.  Enhancement of Interface Characteristics of Neural Probe Based on Graphene, ZnO Nanowires, and Conducting Polymer PEDOT. , 2017, ACS applied materials & interfaces.

[2]  Dong Han,et al.  A 0.45V 100-channel neural-recording IC with sub-µW/channel consumption in 0.18µm CMOS , 2013, 2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers.

[3]  D. Kipke,et al.  In-vivo Evaluation of Chronically Implanted Neural Microelectrode Arrays Modified with Poly (3,4-ethylenedioxythiophene) Nanotubes , 2007, 2007 3rd International IEEE/EMBS Conference on Neural Engineering.

[4]  Timothy Denison,et al.  Integrated circuit amplifiers for multi-electrode intracortical recording , 2009, Journal of neural engineering.

[5]  Jerald D. Kralik,et al.  Chronic, multisite, multielectrode recordings in macaque monkeys , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[6]  Dong Han,et al.  A 0.45 V 100-Channel Neural-Recording IC With Sub-$\mu {\rm W}$/Channel Consumption in 0.18 $\mu{\rm m}$ CMOS , 2013, IEEE Transactions on Biomedical Circuits and Systems.

[7]  K. Wise,et al.  An implantable multielectrode array with on-chip signal processing , 1986 .

[8]  P. Tresco,et al.  Response of brain tissue to chronically implanted neural electrodes , 2005, Journal of Neuroscience Methods.