Preliminary results and simulation of an active pendulum system for a three floor building

Abstract The mitigation of vibrations caused by seismic events has been a long term interest of structural control engineers in their effort to ensure the protection of both civil structures and human occupants. Several control strategies have been used as active vibration suppression methods, especially optimal control strategies such as the linear quadratic regulator. In this paper, a fractional order linear quadratic regulator is designed to cope with the disturbances that may occur in civil structures in the event of an earthquake. The case study consists in a three floor structure equipped with sensors and an active pendulum system to suppress unwanted vibrations. The simulation results show that the proposed controller can effectively achieve the mitigation of structural vibrations.

[1]  Cristina I. Muresan,et al.  A fractional order controller for seismic mitigation of structures equipped with viscoelastic mass dampers , 2016 .

[2]  Hamid Reza Karimi,et al.  Semiactive-passive structural vibration control strategy for adjacent structures under seismic excitation , 2012, J. Frankl. Inst..

[3]  Dominik Sierociuk,et al.  Infinite horizon state-feedback LQR controller for fractional systems , 2010, 49th IEEE Conference on Decision and Control (CDC).

[4]  Touraj Taghikhany,et al.  Direct adaptive algorithm for seismic control of damaged structures with faulty sensors , 2018 .

[5]  Hirokazu Iemura,et al.  Simple algorithm for semi‐active seismic response control of cable‐stayed bridges , 2005 .

[6]  Seyed Mehdi Zahrai,et al.  Semi-active seismic control of an 11-DOF building model with TMD+MR damper using type-1 and -2 fuzzy algorithms , 2018 .

[7]  Keri L. Ryan,et al.  Fractional Order Filter Enhanced LQR for Seismic Protection of Civil Structures , 2008 .

[8]  Egidio Rizzi,et al.  Optimum tuning of Tuned Mass Dampers for frame structures under earthquake excitation , 2015 .

[9]  Yan Li,et al.  Fractional Order Linear Quadratic Regulator , 2008, 2008 IEEE/ASME International Conference on Mechtronic and Embedded Systems and Applications.

[10]  Cristina I. Muresan,et al.  Seismic Mitigation in Civil Structures Using a Fractional Order PD Controller , 2016 .

[11]  J. A. Tenreiro Machado,et al.  New Trends in Nanotechnology and Fractional Calculus Applications , 2010 .

[12]  Satish Nagarajaiah,et al.  Development of a rotation-based negative stiffness device for seismic protection of structures , 2017 .

[13]  Shu Liang,et al.  Representation and LQR of exact fractional order systems , 2014, 53rd IEEE Conference on Decision and Control.

[14]  Wen Yu,et al.  Stability analysis of active vibration control of building structures using PD/PID control , 2014 .

[15]  R. Guclu,et al.  Fuzzy Logic Control of a Non-linear Structural System against Earthquake Induced Vibration , 2007 .

[16]  M. Ohnaka The physics of rock failure and earthquakes , 2013 .