Capacitive Micromachined Ultrasonic Transducers (CMUTs) for Underwater Imaging Applications

A capacitive micromachined ultrasonic transducer structure for use in underwater imaging is designed, fabricated and tested in this paper. In this structure, a silicon dioxide insulation layer is inserted between the top electrodes and the vibration membrane to prevent ohmic contact. The capacitance-voltage (C-V) characteristic curve shows that the transducer offers suitable levels of hysteresis and repeatability performance. The −6 dB center frequency is 540 kHz and the transducer has a bandwidth of 840 kHz for a relative bandwidth of 155%. Underwater pressure of 143.43 Pa is achieved 1 m away from the capacitive micromachined ultrasonic transducer under 20 Vpp excitation. Two-dimensional underwater ultrasonic imaging, which is able to prove that a rectangular object is present underwater, is achieved. The results presented here indicate that our work will be highly beneficial for the establishment of an underwater ultrasonic imaging system.

[1]  Graham A Wright,et al.  Innovations in imaging for chronic total occlusions: a glimpse into the future of angiography's blind-spot. , 2008, European heart journal.

[2]  Douglas A. Buchanan,et al.  Development of a novel configuration for a MEMS transducer for low bias and high resolution imaging applications , 2014, Photonics West - Micro and Nano Fabricated Electromechanical and Optical Components.

[3]  Butrus T. Khuri-Yakub,et al.  Fabrication and characterization of surface micromachined capacitive ultrasonic immersion transducers , 1999 .

[4]  Vittorio Foglietti,et al.  Micromachined capacitive ultrasonic transducers fabricated using silicon on insulator wafers , 2002 .

[5]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  A. Logan,et al.  The Design, Fabrication and Characterization of Capacitive Micromachined Ultrasonic Transducers for Imaging Applications , 2010 .

[7]  O. Oralkan,et al.  Underwater acoustic imaging using capacitive micromachined ultrasonic transducer arrays , 2002, OCEANS '02 MTS/IEEE.

[8]  Butrus T. Khuri-Yakub,et al.  Capacitive Micromachined Ultrasonic Transducers: Theory and Technology , 2003 .

[9]  Mario Kupnik,et al.  Low temperature process for CMUT fabrication with wafer bonding technique , 2010, 2010 IEEE International Ultrasonics Symposium.

[10]  I. Ladabaum,et al.  The microfabrication of capacitive ultrasonic transducers , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[11]  Mario Kupnik,et al.  Capacitive Micromachined Ultrasonic Transducers for Therapeutic Ultrasound Applications , 2010, IEEE Transactions on Biomedical Engineering.

[12]  Dong-Kyun Kim,et al.  Performance and reliability of new CMUT design with improved efficiency , 2013 .

[13]  I. Ladabaum,et al.  Micromachined ultrasonic transducers (MUTs) , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.

[14]  Naseer Sabri,et al.  Capacitive Micromachined Ultrasonic Transducers: Technology and Application , 2012 .

[15]  Pai-Chi Li,et al.  A Capacitive Micromachined Ultrasonic Transducer Array for Minimally Invasive Medical Diagnosis , 2008, Journal of Microelectromechanical Systems.

[16]  Abdullah Atalar,et al.  Wafer bonded capacitive micromachined underwater transducers , 2009, 2009 IEEE International Ultrasonics Symposium.

[17]  Xuefeng Zhuang,et al.  Capacitive micromachined ultrasonic transducers with through-wafer interconnects , 2008 .

[18]  I. Ladabaum,et al.  Theory and analysis of electrode size optimization for capacitive microfabricated ultrasonic transducers , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  Chenyang Xue,et al.  Design and performance analysis of capacitive micromachined ultrasonic transducer (CMUT) array for underwater imaging , 2016 .

[20]  B. Khuri-Yakub,et al.  Fabrication of Capacitive Micromachined Ultrasonic Transducers via Local Oxidation and Direct Wafer Bonding , 2011, Journal of Microelectromechanical Systems.

[21]  U. Gösele,et al.  Low temperature wafer direct bonding , 1994 .

[22]  Robin Shandas,et al.  Capacitive micromachined ultrasonic transducers using commercial multi-user MUMPs process: capability and limitations. , 2009, Ultrasonics.

[23]  J. Sutton Underwater acoustic imaging , 1979, Proceedings of the IEEE.

[24]  S. Severi,et al.  Poly-SiGe-based CMUT array with high acoustical pressure , 2012, 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS).

[25]  Takahiko Suzuki,et al.  Novel technique using intravascular ultrasound-guided guidewire cross in coronary intervention for uncrossable chronic total occlusions. , 2004, Circulation journal : official journal of the Japanese Circulation Society.

[26]  C. A. Rich,et al.  Modeling and Characterization of CMOS-Fabricated Capacitive Micromachined Ultrasound Transducers , 2011, Journal of Microelectromechanical Systems.

[27]  Douglas A. Buchanan,et al.  Multiple Moving Membrane CMUT With Enlarged Membrane Displacement and Low Pull-Down Voltage , 2013, IEEE Electron Device Letters.