Comparison of Insulation Coordination Between ±800kV and ±1100kV UHVDC Systems

Insulation coordination is a key problem in UHVDC systems in terms of safety and cost. Although high-voltage ±1100kV UHVDC projects are being planned in China, the characteristics and key points of high-voltage systems have not yet been analyzed. This study aims to improve the safe, effective operation of these high-voltage power transmission systems. First, we analyzed two typical insulation coordination schemes used in ±800kV UHVDC systems in China. Next, we used the two typical ±800kV insulation coordination schemes as a reference to analyze the ±1100kV UHVDC system. Finally, we compared these schemes and proposed an effective insulation coordination solution, as well as developing principles for ±1100kV UHVDC systems. Our findings indicate that the points enduring the highest voltage in the system should be protected separately by special arresters. Our analysis of the insulation coordination of ±800kV and ±1100kV UHVDC systems concluded that, in ±1100kV UHVDC systems, the main goal of insulation coordination is to lower the insulation level of points enduring the highest voltage. However, in a ±800kV UHVDC system, the main goal is to reduce the cost of manufacture for arresters, as well as the space occupation in the valve hall, with an acceptable insulation level.

[1]  Zhou Hao,et al.  Simulation on lightning overvoltage of ±800kV converter station , 2011, 2011 7th Asia-Pacific International Conference on Lightning.

[2]  Zhao Jie Study on the Overvoltage and Insulation Coordination of Yunnan-Guangdong ±800 kV UHVDC Transmission System , 2009 .

[3]  Zhou,et al.  Overvoltage and Insulation Coordination for ±1 100 kV UHVDC Converter Station , 2013 .

[4]  Huixiang Chen,et al.  Research on DC Transient Overvoltage and Insulation Coordination of ±800kV Converter Station , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.

[5]  Zhou Hao,et al.  Insulation co-ordination of UHVDC transmission lines , 2011, 2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT).

[6]  Wang Dongju,et al.  Overvoltage Protection and Insulation Coordination for ?1 100 kV UHVDC Converter Station , 2012 .

[7]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[8]  Manling Dong,et al.  Influence of smoothing reacteor arrangement on transients of converter station for ±500kV double-circuit HVDC system , 2010, IEEE PES General Meeting.

[9]  Hua Li,et al.  Analysis and Simulation of Monopolar Grounding Fault in Bipolar HVDC Transmission System , 2007, 2007 IEEE Power Engineering Society General Meeting.

[10]  Wu Ya-ni Influence of UHVDC Control and Protection Characteristics on Inner Overvoltage , 2008 .

[11]  Zheng Jin Insulation Coordination for ±800kV UHVDC Converter Stations , 2006 .

[12]  M Haeusler H Huang,et al.  DESIGN AND TESTING OF 800 kV HVDC EQUIPMENT , 2008 .