Mechatronic Design of a Two-Arm Concentric Tube Robot System for Rigid Neuroendoscopy

Open surgical approaches are still often employed in neurosurgery, despite the availability of neuroendoscopic approaches that reduce invasiveness. The challenge of maneuvering instruments at the tip of the endoscope makes neuroendoscopy demanding for the physician. The only way to aim tools passed through endoscope ports is to tilt the entire endoscope; but, tilting compresses brain tissue through which the endoscope passes and can damage it. Concentric tube robots can provide necessary dexterity without endoscope tilting, while passing through existing ports in the endoscope and carrying surgical tools in their inner lumen. In this article, we describe the mechatronic design of a new concentric tube robot that can deploy two concentric tube manipulators through a standard neuroendoscope. The robot uses a compact differential drive and features embedded motor control electronics and redundant position sensors for safety. In addition to the mechatronic design of this system, this article contributes experimental validation in the context of colloid cyst removal, comparing our new robotic system to standard manual endoscopy in a brain phantom. The robotic approach essentially eliminated endoscope tilt during the procedure (17.09$^{\circ }$ for the manual approach vs. 1.16$^{\circ }$ for the robotic system). The robotic system also enables a single surgeon to perform the procedure—typically in a manual approach one surgeon aims the endoscope and another operates the tools delivered through its ports.

[1]  D. Caleb Rucker,et al.  Design of a Quadramanual Robot for Single-Nostril Skull Base Surgery , 2012 .

[2]  K. Yang,et al.  Multiloculated Hydrocephalus: Open Craniotomy or Endoscopy? , 2017, Journal of Korean Neurosurgical Society.

[3]  Robert J. Webster,et al.  Closed-Form Differential Kinematics for Concentric-Tube Continuum Robots with Application to Visual Servoing , 2008, ISER.

[4]  Robert J. Webster,et al.  A Telerobotic System for Transnasal Surgery , 2014, IEEE/ASME Transactions on Mechatronics.

[5]  Robert J. Webster,et al.  Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study , 2015, Int. J. Robotics Res..

[6]  A. Osborn,et al.  Intracranial cysts: radiologic-pathologic correlation and imaging approach. , 2006, Radiology.

[7]  Russell H. Taylor,et al.  A Steady-Hand Robotic System for Microsurgical Augmentation , 1999, Int. J. Robotics Res..

[8]  Robert J. Webster,et al.  Debulking From Within: A Robotic Steerable Cannula for Intracerebral Hemorrhage Evacuation , 2013, IEEE Transactions on Biomedical Engineering.

[9]  A. Raabe,et al.  Robot-assisted navigated endoscopic ventriculostomy: implementation of a new technology and first clinical results , 2004, Acta Neurochirurgica.

[10]  J. Greenlee,et al.  PURELY ENDOSCOPIC RESECTION OF COLLOID CYSTS , 2008, Neurosurgery.

[11]  Y. Tanaka,et al.  Use of a micromanipulator system (NeuRobot) in endoscopic neurosurgery , 2012, Journal of Clinical Neuroscience.

[12]  Pierre E. Dupont,et al.  Torsional kinematic model for concentric tube robots , 2009, 2009 IEEE International Conference on Robotics and Automation.

[13]  Russell H. Taylor,et al.  Medical robotics in computer-integrated surgery , 2003, IEEE Trans. Robotics Autom..

[14]  G. A. Waggenspack,et al.  MR and CT of masses of the anterosuperior third ventricle. , 1989, AJR. American journal of roentgenology.

[15]  Guang-Zhong Yang,et al.  Biometry-based concentric tubes robot for vitreoretinal surgery , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[16]  J. Drake,et al.  Design and evaluation of a new synthetic brain simulator for endoscopic third ventriculostomy. , 2015, Journal of neurosurgery. Pediatrics.

[17]  Robert J. Webster,et al.  Rapid, Reliable Shape Setting of Superelastic Nitinol for Prototyping Robots , 2016, IEEE Robotics and Automation Letters.

[18]  Georgios Fagogenis,et al.  A multiport MR-compatible neuroendoscope: spanning the gap between rigid and flexible scopes. , 2016, Neurosurgical focus.

[19]  B R Lee,et al.  Laparoscopic visual field. Voice vs foot pedal interfaces for control of the AESOP robot. , 1998, Surgical endoscopy.

[20]  Tomer Anor,et al.  Robotic neuro-emdoscope with concentric tube augmentation , 2012, 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[21]  Allison M. Okamura,et al.  Design of a Compact Actuation and Control System for Flexible Medical Robots , 2017, IEEE Robotics and Automation Letters.

[22]  B. Davies A review of robotics in surgery , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[23]  Peter Kazanzides,et al.  Surgical and Interventional Robotics: Core Concepts, Technology, and Design. , 2008, IEEE robotics & automation magazine.

[24]  Dong-Seok Kim,et al.  Neuroendoscopy: Current and Future Perspectives , 2017, Journal of Korean Neurosurgical Society.

[25]  Rajnikant V. Patel,et al.  A fast torsionally compliant kinematic model of concentric-tube robots , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[26]  Michael Y. Wang,et al.  Introduction. Robotics in neurosurgery. , 2017, Neurosurgical focus.

[27]  N. Hopf,et al.  Endoscopic neurosurgery and endoscope-assisted microneurosurgery for the treatment of intracranial cysts. , 1998, Neurosurgery.

[28]  Charles Teo,et al.  Complications of endoscopic neurosurgery , 1996, Child's Nervous System.

[29]  A L Benabid,et al.  Computer-driven robot for stereotactic surgery connected to CT scan and magnetic resonance imaging. Technological design and preliminary results. , 1987, Applied neurophysiology.

[30]  M. Apuzzo,et al.  "Through the looking glass": optical physics, issues, and the evolution of neuroendoscopy. , 2013, World neurosurgery.

[31]  S. Hayati,et al.  A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery , 1988, IEEE Transactions on Biomedical Engineering.

[32]  D. Caleb Rucker,et al.  A Geometrically Exact Model for Externally Loaded Concentric-Tube Continuum Robots , 2010, IEEE Transactions on Robotics.

[33]  M. C. Cavusoglu,et al.  In Touch with Robotics: Neurosurgery for the Future , 2005, Neurosurgery.

[34]  Pierre E. Dupont,et al.  Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.

[35]  Pierre E. Dupont,et al.  Concentric Tube Robot Design and Optimization Based on Task and Anatomical Constraints , 2015, IEEE Transactions on Robotics.

[36]  Rajiv Gupta,et al.  Compact Robotically Steerable Image-Guided Instrument for Multi-Adjacent-Point (MAP) Targeting , 2014, IEEE Transactions on Robotics.

[37]  M. Souweidane Endoscopic management of pediatric brain tumors. , 2005, Neurosurgical focus.

[38]  Robert J. Webster,et al.  Designing snap-free concentric tube robots: A local bifurcation approach , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[39]  Robert J. Webster,et al.  On the computational design of concentric tube robots: Incorporating volume-based objectives , 2013, 2013 IEEE International Conference on Robotics and Automation.

[40]  Paul Milgram,et al.  104 Design and Evaluation of a Concentric Tube Robot for Minimally-Invasive Endoscopic Pediatric Neurosurgery , 2014 .

[41]  B L Wise A review of brain retraction and recommendations for minimizing intraoperative brain injury. , 1994, Neurosurgery.