Development of an automated processing method to detect still timing of cardiac motion for coronary magnetic resonance angiography

Whole-heart coronary magnetic resonance angiography (WH-MRA) is useful noninvasive examination. Its signal acquisition is performed during very short still timing in each cardiac motion cycle, and therefore the adequate still timing selection is important to obtain the better image quality. However, since the current available selection method is only manual one using visual comparison of cine MRI images with different phases, the selected timings are often incorrect and their reproducibility is not sufficient. We developed an automated selection method to detect the best still timing for the WH-MRA and compared the automated method with conventional manual one. Cine MRI images were used for the analysis. In order to extract the high-speed cardiac cine image, each phase directional pixel set at each pixel position in all cine images were processed by a high-pass filtering using the Fourie transform. After this process, the cine images with low speed timing became dark, and the optimal timing could be determined by a threshold processing. We took ten volunteers' WH-MRA with the manually and automatically selected timings, and visually assessed image quality of each image on a 5-point scale (1=excellent, 2=very good, 3=good, 4=fair, 5=poor). The mean scores of the manual and automatic methods for right coronary arteries (RCA), LDA left anterior descending arteries (LAD) and LCX left circumflex arteries (LCX) were 4.2±0.38, 4.1±0.44, 3.9±0.52 and 4.1±0.42, 4.1±0.24, 3.2±0.35 respectively. The score were increased by our method in the RCA and LCX, and the LCX was significant (p<0.05). As the results, it was indicated that our automated method could determine the optimal cardiac phase more accurately than or equally to the conventional manual method.

[1]  Alastair J. Martin,et al.  Whole‐heart steady‐state free precession coronary artery magnetic resonance angiography , 2003, Magnetic resonance in medicine.

[2]  M. Van Cauteren,et al.  Assessment of coronary arteries with total study time of less than 30 minutes by using whole-heart coronary MR angiography. , 2005, Radiology.

[3]  Klaus Scheffler,et al.  On the transient phase of balanced SSFP sequences , 2003, Magnetic resonance in medicine.

[4]  S. Dymarkowski,et al.  Coronary artery imaging with real-time navigator three-dimensional turbo-field-echo MR coronary angiography: initial experience. , 2003, Radiology.

[5]  J. Finn,et al.  Cardiac MR imaging: state of the technology. , 2006, Radiology.

[6]  Yi Wang,et al.  Direct monitoring of coronary artery motion with cardiac fat navigator echoes , 2003, Magnetic resonance in medicine.

[7]  Kay Nehrke,et al.  Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance. , 2005, European heart journal.

[8]  René M. Botnar,et al.  Coronary Magnetic Resonance Angiography , 2003, Herz.

[9]  René M. Botnar,et al.  Comparison of three-dimensional coronary magnetic resonance angiography with x-ray angiography for detection of coronary artery stenoses , 2001 .

[10]  Kazufumi Suzuki,et al.  Compression belt for navigator-triggered trueFISP whole-heart coronary magnetic resonance angiography: study in healthy volunteers. , 2008, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.

[11]  Feasibility of navigator setting on the left diaphragm for whole-heart coronary MRA: a study in healthy volunteers. , 2009, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.

[12]  Eckart Fleck,et al.  Coronary MR angiography with steady-state free precession: individually adapted breath-hold technique versus free-breathing technique. , 2004, Radiology.