Comparison of various detection limit estimates for volatile sulphur compounds by gas chromatography with pulsed flame photometric detection.

This paper addresses the variations that presently exist regarding the definition, determination, and reporting of detection limits for volatile sulphur compounds by gas chromatography with pulsed flame photometric detection (GC-PFPD). Gas standards containing hydrogen sulphide (H(2)S), carbonyl sulphide (COS), sulphur dioxide (SO(2)), methyl mercaptan (CH(3)SH), dimethyl sulphide (DMS), carbon disulphide (CS(2)), and dimethyl disulphide (DMDS) in concentrations varying from 0.36ppb (v/v) up to 1.5ppm (v/v) in nitrogen were prepared with permeation tubes and introduced in the gas chromatograph using a 0.25-ml gas sampling loop. After measuring the PFPD response versus concentration, the method detection limit (MDL), the Hubaux-Vos detection limit (x(D)), the absolute instrument sensitivity (AIS), and the sulphur detectivity (D(s)) were determined for each sulphur compound. The results show that the MDL determined by the US Environmental Protection Agency procedure consistently underestimates the minimum concentrations of volatile sulphur compounds that can be practically distinguished from the background noise with the PFPD. The Hubaux-Vos detection limits and the AIS values are several times higher than the MDL, and provide more conservative estimates of the lowest concentrations that can be reliably detected. Sulphur detectivities are well correlated with AIS values but only poorly correlated with MDL values. The AIS is recommended as a reliable and cost-effective measure of detection limit for volatile sulphur compounds by GC-PFPD, since the AIS is easier and faster to determine than the MDL and the Hubaux-Vos detection limit. In addition, this study confirmed that the PFPD response is nearly quadratic with respect to concentration for all volatile sulphur compounds.

[1]  John Aurie Dean,et al.  Instrumental methods of analysis , 1951 .

[2]  Ki-Hyun Kim,et al.  Performance characterization of the GC/PFPD for H2S, CH3SH, DMS, and DMDS in air , 2005 .

[3]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[4]  W. Wardencki Problems with the determination of environmental sulphur compounds by gas chromatography , 1998 .

[5]  François Lestremau,et al.  Development of a quantification method for the analysis of malodorous sulphur compounds in gaseous industrial effluents by solid-phase microextraction and gas chromatography-pulsed flame photometric detection. , 2003, Journal of chromatography. A.

[6]  D. MacDougall,et al.  Guidelines for data acquisition and data quality evaluation in environmental chemistry , 1980 .

[7]  Ki‐Hyun Kim,et al.  The evaluation of recovery rate associated with the use of thermal desorption systems for the analysis of atmospheric reduced sulfur compounds (RSC) using the GC/PFPD method. , 2005, Talanta.

[8]  A. Amirav,et al.  Pulsed-flame photometer: a novel gas chromatography detector , 1993 .

[9]  Youn-Sang Choi,et al.  Characterization of malodorous sulfur compounds in landfill gas , 2005 .

[10]  W. Sye,et al.  Determination of odorous sulfur compounds in air by Tenax GR preconcentration and capillary gas chromatography in combination with flameless sulfur chemiluminescence detection , 2000 .

[11]  Andre. Hubaux,et al.  Decision and detection limits for calibration curves , 1970 .

[12]  Joan U. Clarke,et al.  Analytical Chemistry Detection Limits and the Evaluation of Dredged Sediments , 2005 .

[13]  Ki-Hyun Kim,et al.  The properties of calibration errors in the analysis of reduced sulfur compounds by the combination of a loop injection system and gas chromatography with pulsed flame photometric detection , 2006 .

[14]  Ki‐Hyun Kim,et al.  The effects of sampling materials selection in the collection of reduced sulfur compounds in air. , 2006, Talanta.

[15]  A. Amirav,et al.  Pulsed Flame Photometer Detector for Gas Chromatography , 1995 .

[16]  Y. Inomata,et al.  Simultaneous measurement of volatile sulfur compounds using ascorbic acid for oxidant removal and gas chromatography-flame photometric detection. , 1999, Journal of chromatography. A.

[17]  Ki-Hyun Kim,et al.  Some insights into the gas chromatographic determination of reduced sulfur compounds (RSCs) in air. , 2005, Environmental science & technology.