Switching faults and safe control of an ARCP multicell flying capacitor inverter

The auxiliary resonant commutated pole (ARCP) multicell converter is a soft-switched variant of the multicell converter. It is shown in this paper that the ARCP technique can be very efficiently used in multicell flying capacitor converters. The main properties of the resulting soft switching multicell converter are very similar to those of the hard-switched version. They are presented and validated by simulations as well as experimental results. In practice, due to the damping, the ARCP multicell converter can suffer from switching faults as in two-level ARCP inverters, but in the case of a multicell converter failures can occur in different cells. So, the main control strategies are evaluated and the switching process is discussed step by step, taking account of the main imperfections of actual control circuits. When they can occur, the switching faults are described and analyzed. Finally, an original quasisoft switching control that should give a high safety of operation is proposed. Experimental results obtained with a 900 V-100 A ARCP multicell inverter leg are given and the performances are compared with those of a hard-switched multicell inverter leg of the same rating.

[1]  J.L. Duarte,et al.  Multi-level converter with auxiliary resonant-commutated pole , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[2]  H. J. Beukes,et al.  Performance of the auxiliary resonant commutated pole converter in converter based utility devices , 1996, PESC Record. 27th Annual IEEE Power Electronics Specialists Conference.

[3]  Thierry Meynard,et al.  Multicell converters: derived topologies , 2002, IEEE Trans. Ind. Electron..

[4]  Thierry Meynard,et al.  Failures-tolerance and remedial strategies of a PWM multicell inverter , 2002 .

[5]  Thierry Meynard,et al.  Multi-Level Choppers for High Voltage Applications , 1992 .

[6]  Thierry Meynard,et al.  Evaluation of High Power Converters by the Opposition Method , 2002 .

[7]  H. J. Beukes,et al.  Control complexities related to high power resonant inverters , 1996, PESC Record. 27th Annual IEEE Power Electronics Specialists Conference.

[8]  I. Barbi,et al.  Zero-voltage switching for three-level capacitor clamping inverter , 1999 .

[9]  Jung G. Cho,et al.  Three level auxiliary resonant commutated pole inverter for high power applications , 1996, PESC Record. 27th Annual IEEE Power Electronics Specialists Conference.

[10]  Thierry Meynard,et al.  A ZVS imbricated cell multilevel inverter with auxiliary resonant commutated poles , 2002 .

[11]  T.A. Meynard,et al.  Multi-level conversion: high voltage choppers and voltage-source inverters , 1992, PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference.

[12]  Dong-Wook Yoo,et al.  Zero-voltage-switching three-level auxiliary resonant commutated pole inverter for high-power applications , 1995 .

[13]  Thierry Meynard,et al.  Modeling of multilevel converters , 1997, IEEE Trans. Ind. Electron..

[14]  R.W. De Doncker,et al.  The auxiliary resonant commutated pole converter , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[15]  Frede Blaabjerg,et al.  Link voltage peak control of parallel resonant converter by control of the converter switching instant , 1995 .