Non-contact biomedical photoacoustic and ultrasound imaging.

The detection of ultrasound in photoacoustic tomography (PAT) usually relies on ultrasonic transducers in contact with the biological tissue through a coupling medium. This is a major drawback for important potential applications such as surgery. Here we report the use of a remote optical method, derived from industrial laser-ultrasonics, to detect ultrasound in tissues. This approach enables non-contact PAT (NCPAT) without exceeding laser exposure safety limits. The sensitivity of the method is based on the use of suitably shaped detection laser pulses and a confocal Fabry-Perot interferometer in differential configuration. Reliable image reconstruction is obtained by measuring remotely the surface profile of the tissue with an optical coherence tomography system. The proposed method also allows non-contact ultrasound imaging (US) by applying a second reconstruction algorithm to the data acquired for NCPAT. Endogenous and exogenous inclusions exhibiting optical and acoustic contrasts were detected ex vivo in chicken breast and calf brain specimens. Inclusions down to 0.3 mm in size were detected at depths exceeding 1 cm. The method could expand the scope of photoacoustic and US to in-vivo biomedical applications where contact is impractical.

[1]  Lihong V. Wang,et al.  Biomedical Optics: Principles and Imaging , 2007 .

[2]  G. D. den Heeten,et al.  Feasibility of noncontact piezoelectric detection of photoacoustic signals in tissue-mimicking phantoms. , 2010, Journal of biomedical optics.

[3]  Jean-Pierre Monchalin,et al.  Broadband optical detection of ultrasound by two‐wave mixing in a photorefractive crystal , 1991 .

[4]  W. Drexler,et al.  Multimodal photoacoustic and optical coherence tomography scanner using an all optical detection scheme for 3D morphological skin imaging , 2011, Biomedical optics express.

[5]  Alexander A. Oraevsky,et al.  Two-dimensional optoacoustic tomography: transducer array and image reconstruction algorithm , 1999, Photonics West - Biomedical Optics.

[6]  Vasilis Ntziachristos,et al.  Current concepts and future perspectives on surgical optical imaging in cancer. , 2010, Journal of biomedical optics.

[7]  Fred P. Seeber,et al.  OP-TEC national center for optics and photonics education and ANSI Z136.5 American National Standard for the safe use of lasers in educational institutions – How they will work together to improve laser safety in educational institutions , 2009 .

[8]  Lihong V. Wang,et al.  Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging , 2006, Nature Biotechnology.

[9]  Ruikang K. Wang,et al.  Noncontact photoacoustic imaging achieved by using a low-coherence interferometer as the acoustic detector. , 2011, Optics letters.

[10]  Lihong V. Wang Photoacoustic imaging and spectroscopy , 2009 .

[11]  Thomas Berer,et al.  Three dimensional photoacoustic imaging using fiber-based line detectors , 2010 .

[12]  Bernhard Reitinger,et al.  Downstream Fabry-Perot interferometer for acoustic wave monitoring in photoacoustic tomography. , 2011, Optics letters.

[13]  D Lévesque,et al.  Performance of laser-ultrasonic F-SAFT imaging. , 2002, Ultrasonics.

[14]  Peter Cawley,et al.  Review of Synthetically Focused Guided Wave Imaging Techniques With Application to Defect Sizing , 2006 .

[15]  M. Hewko,et al.  Optical delay line using rotating rhombic prisms , 2007, SPIE BiOS.

[16]  J. Monchalin Optical Detection of Ultrasound , 1986, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Lihong V. Wang,et al.  Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain , 2003, Nature Biotechnology.

[18]  Jean-Pierre Monchalin,et al.  Detection of ultrasonic motion of a scattering surface by two‐wave mixing in a photorefractive GaAs crystal , 1994 .

[19]  Alain Blouin,et al.  Differential Confocal Fabry-Perot for the Optical Detection of Ultrasound , 2007 .

[20]  P. Beard Biomedical photoacoustic imaging , 2011, Interface Focus.

[21]  Thomas Berer,et al.  Remote photoacoustic imaging on solid material using a two-wave mixing interferometer. , 2010, Optics letters.

[22]  L. Drain,et al.  Laser Ultrasonics Techniques and Applications , 1990 .

[23]  Lihong V. Wang,et al.  In vivo dark-field reflection-mode photoacoustic microscopy. , 2005, Optics letters.

[24]  Jean-Pierre Monchalin,et al.  Non-contact photoacoustic tomography and ultrasonography for tissue imaging , 2011, Biomedical optics express.

[25]  Shuliang Jiao,et al.  Photoacoustic ophthalmoscopy for in vivo retinal imaging: current status and prospects. , 2011, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[26]  J. Monchalin Optical detection of ultrasound at a distance using a confocal Fabry–Perot interferometer , 1985 .

[27]  Vasan Venugopalan,et al.  Optoacoustic tomography using time-resolved interferometric detection of surface displacement. , 2003, Journal of biomedical optics.