Numerical simulation of in vitro pulsatile flow and its study using FRISK, a rapid phase contrast technique

To test the potential of a phase contrast magnetic resonance (PC‐MR) sparse sampling technique, fragmented regional interpolation segmentation for k‐space (FRISK), to capture complex flow features within a breathhold duration by using numerical simulations and experimental approaches.

[1]  R. Balaban,et al.  Myocardial velocity gradient imaging by phase contrast MRI with application to regional function in myocardial ischemia , 1999, Magnetic resonance in medicine.

[2]  R Frayne,et al.  MR measurement and numerical simulation of steady flow in an end-to-side anastomosis model. , 1996, Journal of biomechanics.

[3]  Dimitri Deserranno,et al.  Effect of jet eccentricity on functional severity of congenital aortic stenosis , 2002 .

[4]  N J Pelc,et al.  Renal artery blood flow: quantitation with phase-contrast MR imaging with and without breath holding. , 1994, Radiology.

[5]  D. Pennell,et al.  Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. , 2002, Radiology.

[6]  C. Meier,et al.  Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. , 2002, Radiographics : a review publication of the Radiological Society of North America, Inc.

[7]  R. Mohiaddin,et al.  Applications of phase-contrast flow and velocity imaging in cardiovascular MRI , 2005, European Radiology.

[8]  G M Pohost,et al.  Rapid cardiac imaging with turbo BRISK , 1997, Magnetic resonance in medicine.

[9]  M Doyle,et al.  Rapid velocity-encoded cine imaging with turbo-BRISK. , 1999, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[10]  Mark Doyle,et al.  Validation of Rapid Velocity Encoded Cine Imaging of a Dynamically Complex Flow Field Using Turbo Block Regional Interpolation Scheme for k Space , 2001, Annals of Biomedical Engineering.

[11]  J Hennig,et al.  Phase contrast MRI with improved temporal resolution by view sharing: k-space related velocity mapping properties. , 2001, Magnetic resonance imaging.

[12]  K Takeda,et al.  Assessment of coronary flow reserve with fast cine phase contrast magnetic resonance imaging: Comparison with measurement by Doppler guide wire , 1999, Journal of magnetic resonance imaging : JMRI.

[13]  C. Higgins,et al.  Coronary flow reserve: assessment by magnetic resonance imaging. , 1999, Rays.

[14]  C. R. Ethier,et al.  Combined analysis of spatial and velocity displacement artifacts in phase contrast measurements of complex flows , 1997, Journal of magnetic resonance imaging : JMRI.

[15]  G. Pohost,et al.  Block Regional Interpolation Scheme for k‐Space (BRISK): A Rapid Cardiac Imaging Technique , 1995, Magnetic resonance in medicine.

[16]  Mark Doyle,et al.  Extension of Rapid Phase-Contrast Magnetic Resonance Imaging Using BRISK in Multidirectional Flow , 2005, Annals of Biomedical Engineering.

[17]  David N. Firmin,et al.  Magnetic Resonance Jet Velocity Mapping in Mitral and Aortic Valve Stenosis , 1993, Circulation.

[18]  J. M. Siegel,et al.  The accuracy of magnetic resonance phase velocity measurements in stenotic flow. , 1996, Journal of biomechanics.

[19]  Richard B Thompson,et al.  High temporal resolution phase contrast MRI with multiecho acquisitions † , 2002, Magnetic resonance in medicine.

[20]  Konstantin Nikolaou,et al.  Quantification of Pulmonary Blood Flow and Volume in Healthy Volunteers by Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using a Parallel Imaging Technique , 2004, Investigative radiology.

[21]  Kazuhiro Nakahashi,et al.  Multiple Marching Direction Approach to Generate High-Quality Hybrid Meshes , 2007 .

[22]  Jan Engvall,et al.  Three-directional myocardial motion assessed using 3D phase contrast MRI. , 2004, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[23]  Mark Doyle,et al.  Correction of temporal misregistration artifacts in jet flow by conventional phase‐contrast MRI , 2007, Journal of magnetic resonance imaging : JMRI.