EEG/(f)MRI measurements at 7 Tesla using a new EEG cap (“InkCap”)

We aimed at improving the signal-to-noise ratio (SNR) of electroencephalography (EEG) during magnetic resonance imaging (MRI) by introducing a new EEG cap ("InkCap") based on conductive ink technology. The InkCap was tested with temperature measurements on an electrically conductive phantom head and during structural and functional MRI (fMRI) recordings in 11 healthy human volunteers at 7 T. Combined EEG/fMRI measurements were conducted to study the interaction between the two modalities. The EEG recordings with the InkCap demonstrated up to a five-fold average decrease in signal variance during echo-planar imaging, with respect to a cap made of standard carbon fiber leads. During concurrent EEG/fMRI measurements in human volunteers, alpha oscillations were clearly detected at 7 T. Minimal artifacts were present in the T2* and high-resolution structural MR images of the brain parenchyma. Our results show that the InkCap technology considerably improves the quality of both EEG and (f)MRI during concurrent measurements even at 7 T.

[1]  Bradley G. Goodyear,et al.  Simultaneous 3-T fMRI and high-density recording of human auditory evoked potentials , 2004, NeuroImage.

[2]  D. Regan Human brain electrophysiology: Evoked potentials and evoked magnetic fields in science and medicine , 1989 .

[3]  J. R. Baker,et al.  Simultaneous functional magnetic resonance imaging and electrophysiological recording , 1995 .

[4]  Mohan Edirisinghe,et al.  Dispersion and stability of silver inks , 2002 .

[5]  J Gotman,et al.  Intrinsic epileptogenicity in polymicrogyric cortex suggested by EEG-fMRI BOLD responses , 2005, Neurology.

[6]  Alberto Inuggi,et al.  Visual evoked potentials may be recorded simultaneously with fMRI scanning: A validation study , 2005, Human brain mapping.

[7]  Chantal Delon-Martin,et al.  Sequence of pattern onset responses in the human visual areas: an fMRI constrained VEP source analysis , 2004, NeuroImage.

[8]  R. Murdick,et al.  Magneto-encephalogram artifacts caused by electro-encephalogram electrodes , 2006, Medical and Biological Engineering and Computing.

[9]  J. Belliveau,et al.  Metallic electrodes and leads in simultaneous EEG‐MRI: Specific absorption rate (SAR) simulation studies , 2004, Bioelectromagnetics.

[10]  Tetsuya Matsuda,et al.  Influence of arousal level for functional magnetic resonance imaging (fMRI) study: Simultaneous recording of fMRI and electroencephalogram , 2002, Psychiatry and clinical neurosciences.

[11]  Emmanuel Perrin,et al.  RF‐induced temperature elevation along metallic wires in clinical magnetic resonance imaging: Influence of diameter and length , 2004, Magnetic resonance in medicine.

[12]  R. Goebel,et al.  7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head images , 2001, Magnetic resonance in medicine.

[13]  E. Halgren,et al.  Dynamic Statistical Parametric Mapping Combining fMRI and MEG for High-Resolution Imaging of Cortical Activity , 2000, Neuron.

[14]  Masato Yumoto,et al.  Stepping stone sampling for retrieving artifact-free electroencephalogram during functional magnetic resonance imaging , 2003, NeuroImage.

[15]  Anthony Turner,et al.  Solvent-resistant carbon electrodes screen printed onto plastic for use in biosensors , 1997 .

[16]  Robert Turner,et al.  A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI , 2000, NeuroImage.

[17]  Frank Bihari,et al.  MRI compatible EEG electrode system for routine use in the epilepsy monitoring unit and intensive care unit , 2004, Clinical Neurophysiology.

[18]  L. Lemieux,et al.  Recording of EEG during fMRI experiments: Patient safety , 1997, Magnetic resonance in medicine.

[19]  A K Liu,et al.  Spatiotemporal imaging of human brain activity using functional MRI constrained magnetoencephalography data: Monte Carlo simulations. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[20]  S. J. Allen,et al.  Thermophysiological responses of human volunteers to whole body RF exposure at 220 MHz , 2005, Bioelectromagnetics.

[21]  James C. Lin,et al.  Radio frequency electromagnetic exposure: tutorial review on experimental dosimetry. , 1996, Bioelectromagnetics.

[22]  Christoph Mulert,et al.  Sound level dependence of the primary auditory cortex: Simultaneous measurement with 61-channel EEG and fMRI , 2005, NeuroImage.

[23]  Mark S. Cohen,et al.  Acquiring simultaneous EEG and functional MRI , 2000, Clinical Neurophysiology.

[24]  Jeffrey R. Binder,et al.  Simultaneous ERP and fMRI of the auditory cortex in a passive oddball paradigm , 2003, NeuroImage.

[25]  J. Gotman,et al.  Quality of EEG in simultaneous EEG-fMRI for epilepsy , 2003, Clinical Neurophysiology.

[26]  Lawrence L. Wald,et al.  Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters , 2005, NeuroImage.

[27]  Rami K. Niazy,et al.  Simultaneous recording of laser-evoked brain potentials and continuous, high-field functional magnetic resonance imaging in humans , 2005, NeuroImage.

[28]  Bin He,et al.  On the estimation of the number of dipole sources in EEG source localization , 2005, Clinical Neurophysiology.

[29]  Emery N. Brown,et al.  Motion and Ballistocardiogram Artifact Removal for Interleaved Recording of EEG and EPs during MRI , 2002, NeuroImage.

[30]  G. Bonmassar,et al.  Resistive tapered stripline (RTS) in electroencephalogram recordings during MRI , 2004, IEEE Transactions on Microwave Theory and Techniques.

[31]  K. Chiappa,et al.  EEG during MR imaging , 1995, Neurology.

[32]  L. Wald,et al.  Eight‐channel phased array coil and detunable TEM volume coil for 7 T brain imaging , 2005, Magnetic resonance in medicine.

[33]  A. M. Dale,et al.  Spatiotemporal Brain Imaging of Visual-Evoked Activity Using Interleaved EEG and fMRI Recordings , 2001, NeuroImage.

[34]  K. Uğurbil,et al.  Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz , 2004, Journal of magnetic resonance imaging : JMRI.

[35]  Paul Horowitz,et al.  The Art of Electronics , 1980 .

[36]  Giorgio Bonmassar,et al.  On the effect of resistive EEG electrodes and leads during 7 T MRI: simulation and temperature measurement studies. , 2006, Magnetic resonance imaging.

[37]  R. Buxton Introduction to Functional Magnetic Resonance Imaging: Principles and Techniques , 2002 .

[38]  M Seeck,et al.  EEG-Linked functional magnetic resonance imaging in epilepsy and cognitive neurophysiology. , 2000, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.