Effects of stent porosity on hemodynamics in a sidewall aneurysm model.

Computation and experiment have been complementarily performed to study the fluid flow inside a stented lateral aneurysm anchored on the straight parent vessel. The implicit solver was based on the time-dependent incompressible Navier-Stokes equations of laminar flow. Solutions were generated by a cell-center finite-volume method that used second-order upwind and second-order center flux difference splitting for the convection and diffusion term, respectively. The second-order Crank-Nicolson method was used in the time integration term. Experimental techniques used were flow visualization (FV) and particle tracking velocimetry (PTV). Experimentally, the straight afferent vessel had an inner diameter 10mm. The diameters of the aneurysmal orifice, neck, and fundus were 14, 10, and 15 mm, respectively, and the distance between the orifice and dome measured 20mm. A 30 mm long helix-shaped stent was tested. Four stent porosities of 100%, 70%, 50%, and 25% were examined. Volume-flow rate waveform of a cerebral artery was considered with a maximum Reynolds number of 250 and Womersley number of 3.9. Results are presented in terms of the pulsatile main and secondary flow velocity vector fields, the volume inflow rates into the aneurysm, and the wall shear stress (WSS) and wall pressure at the aneurysm dome. Some comparisons of computed results with the present FV and PTV results and with the data available from the literature are also made. The maximum flow velocity inside the aneurysm ostium and the WSS in the dome region at the peak flow can, respectively, be suppressed to less than 5% of the parent vessel bulk velocity (or 20% of the unstented case) and 8% of the unstented case if the stent porosity is smaller than 40% (about the porosity of the two-layer stents). In general, the three-layer stents seem not as effective as the two-layer stents in reducing the magnitude of aneurysm inflow rate and WSS.

[1]  A. Wakhloo,et al.  Modeling of flow in a straight stented and nonstented side wall aneurysm model. , 1997, Journal of biomechanical engineering.

[2]  L. Brush,et al.  McDonaldʼs Blood Flow in Arteries , 1991 .

[3]  Patrick W. Serruys,et al.  Handbook of Coronary Stents , 1997 .

[4]  A Campi,et al.  Treatment of a ruptured dissecting vertebral artery aneurysm with double stent placement: case report. , 2001, AJNR. American journal of neuroradiology.

[5]  M. P. Judkins,et al.  Transluminal Treatment of Arteriosclerotic Obstruction: Description of a New Technic and a Preliminary Report of Its Application , 1964, Circulation.

[6]  Kyehan Rhee,et al.  Changes of Flow Characteristics by Stenting in Aneurysm Models: Influence of Aneurysm Geometry and Stent Porosity , 2002, Annals of Biomedical Engineering.

[7]  J. Klisch,et al.  Life-threatening bleeding from a vertebral artery pseudoaneurysm after anterior cervical spine approach: endovascular repair by a triple stent-in-stent method. Case report , 2005, Neuroradiology.

[8]  S. C. Yu,et al.  A steady flow analysis on the stented and non-stented sidewall aneurysm models. , 1999, Medical engineering & physics.

[9]  T. Liou,et al.  Numerical and experimental studies on pulsatile flow in aneurysms arising laterally from a curved parent vessel at various angles. , 2007, Journal of biomechanics.

[10]  K. Perktold,et al.  Hemodynamics in rigid and distensible saccular aneurysms: a numerical study of pulsatile flow characteristics. , 1993, Biorheology.

[11]  T CRAWFORD,et al.  SOME OBSERVATIONS ON THE PATHOGENESIS AND NATURAL HISTORY OF INTRACRANIAL ANEURYSMS , 1959, Journal of neurology, neurosurgery, and psychiatry.

[12]  C. R. Ethier,et al.  Requirements for mesh resolution in 3D computational hemodynamics. , 2001, Journal of biomechanical engineering.

[13]  J P Cooke,et al.  Flow stimulates endothelial cells to release a nitrovasodilator that is potentiated by reduced thiol. , 1990, The American journal of physiology.

[14]  S. Alper,et al.  Hemodynamic shear stress and its role in atherosclerosis. , 1999, JAMA.

[15]  J. W. Jukema Handbook of Coronary Stents; fourth edition , 2002 .

[16]  J Haberstroh,et al.  Self-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model. , 1994, AJNR. American journal of neuroradiology.

[17]  T. Liou,et al.  Intra-aneurysmal flow with helix and mesh stent placement across side-wall aneurysm pore of a straight parent vessel. , 2004, Journal of biomechanical engineering.

[18]  David A Steinman,et al.  Finite-element modeling of the hemodynamics of stented aneurysms. , 2004, Journal of biomechanical engineering.

[19]  J. L. Counord,et al.  In vitro study of haemodynamics in a giant saccular aneurysm model: influence of flow dynamics in the parent vessel and effects of coil embolisation , 1994, Neuroradiology.

[20]  B Lane,et al.  Stent placement for arterial and venous cerebrovascular disease: preliminary experience. , 1994, Radiology.

[21]  D. A. Mcdonald Blood flow in arteries , 1974 .

[22]  A. Wakhloo,et al.  Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity , 1997, Annals of Biomedical Engineering.

[23]  G. Geremia,et al.  Embolization of experimentally created aneurysms with intravascular stent devices. , 1992, AJNR. American journal of neuroradiology.