Pulse contour cardiac output derived from non‐invasive arterial pressure in cardiovascular disease

Pulse contour methods determine cardiac output semi‐invasively using standard arterial access. This study assessed whether cardiac output can be determined non‐invasively by replacing the intra‐arterial pressure input with a non‐invasive finger arterial pressure input in two methods, Nexfin CO‐trek® and Modelflow®, in 25 awake patients after coronary artery bypass surgery. Pulmonary artery thermodilution cardiac output served as a reference. In the supine position, the mean (SD) differences between thermodilution cardiac output and Nexfin CO‐trek were 0.22 (0.77) and 0.44 (0.81) l.min−1, for intra‐arterial and non‐invasive pressures, respectively. For Modelflow, these differences were 0.70 (1.08) and 1.80 (1.59) l.min−1, respectively. Similarly, in the sitting position, differences between thermodilution cardiac output and Nexfin CO‐trek were 0.16 (0.78) and 0.34 (0.83), for intra‐arterial and non‐invasive arterial pressure, respectively. For Modelflow, these differences were 0.58 (1.11) and 1.52 (1.54) l.min−1, respectively. Thus, Nexfin CO‐trek readings were not different from thermodilution cardiac output, for both invasive and non‐invasive inputs. However, Modelflow readings differed greatly from thermodilution when using non‐invasive arterial pressure input.

[1]  S. Fleming,et al.  Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery. , 2005, British journal of anaesthesia.

[2]  J. V. van Lieshout,et al.  Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger , 2005, Experimental physiology.

[3]  J. Sugawara,et al.  Non-invasive assessment of cardiac output during exercise in healthy young humans: comparison between Modelflow method and Doppler echocardiography method. , 2003, Acta physiologica Scandinavica.

[4]  N. Westerhof,et al.  An artificial arterial system for pumping hearts. , 1971, Journal of applied physiology.

[5]  L. Critchley,et al.  A Meta-Analysis of Studies Using Bias and Precision Statistics to Compare Cardiac Output Measurement Techniques , 1999, Journal of Clinical Monitoring and Computing.

[6]  J R Jansen,et al.  Computation of aortic flow from pressure in humans using a nonlinear, three-element model. , 1993, Journal of applied physiology.

[7]  R M Gardner,et al.  Direct blood pressure measurement--dynamic response requirements. , 1981, Anesthesiology.

[8]  Karel H Wesseling,et al.  Validation of brachial artery pressure reconstruction from finger arterial pressure , 2008, Journal of hypertension.

[9]  Peter Nissen,et al.  Techniques of cardiac output measurement during liver transplantation: Arterial pulse wave versus thermodilution , 2009, Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society.

[10]  Vic Hasselblad,et al.  Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials. , 2005, JAMA.

[11]  J Van Goudoever,et al.  Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress. , 1999, Clinical science.

[12]  R. Venn,et al.  Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. , 2002, British journal of anaesthesia.

[13]  K H Wesseling,et al.  Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger. , 1985, Cardiovascular research.

[14]  Berend E. Westerhof,et al.  The arterial Windkessel , 2009, Medical & Biological Engineering & Computing.

[15]  K H Wesseling,et al.  Models of brachial to finger pulse wave distortion and pressure decrement. , 1997, Cardiovascular research.

[16]  N. T. Smith,et al.  A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. , 2001, British journal of anaesthesia.

[17]  Morten Eriksen,et al.  Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound , 2003, European Journal of Applied Physiology.

[18]  R. Woolmer Measurement in anaesthesia. , 1961, Annals of the Royal College of Surgeons of England.

[19]  J. Jansen,et al.  An adequate strategy for the thermodilution technique in patients during mechanical ventilation , 1990, Intensive Care Medicine.

[20]  M. Eriksen,et al.  Respiration‐synchronous fluctuations in stroke volume, heart rate and arterial pressure in humans. , 1993, The Journal of physiology.

[21]  Karel H Wesseling,et al.  Reconstruction of brachial pressure from finger arterial pressure during orthostasis , 2004, Journal of hypertension.

[22]  L. Brochard,et al.  Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. , 2003, JAMA.

[23]  N. Stergiopulos,et al.  Arterial pressure transfer characteristics: effects of travel time. , 2007, American journal of physiology. Heart and circulatory physiology.

[24]  K H Wesseling,et al.  Reconstruction of brachial artery pressure from noninvasive finger pressure measurements. , 1996, Circulation.

[25]  K. Wesseling,et al.  Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: a comparison with bolus injection thermodilution. , 1999, Anesthesiology.

[26]  J. V. van Lieshout,et al.  A definition of normovolaemia and consequences for cardiovascular control during orthostatic and environmental stress , 2010, European Journal of Applied Physiology.

[27]  G. Langewouters,et al.  Age-Related Changes in Viscoelasticity of Normal and Arteriosclerotic Human Aortas , 1985 .

[28]  J. Peňáz Criteria for set point estimation in the volume clamp method of blood pressure measurement. , 1992, Physiological research.

[29]  N. T. Smith,et al.  Beat to Beat Cardiac Output from the Arterial Pressure Pulse Contour , 1974 .

[30]  J. J. Settels,et al.  Physiocal, calibrating finger vascular physiology for finapres , 1995 .

[31]  H. Kehlet,et al.  Goal-directed perioperative fluid management: why, when, and how? , 2009, Anesthesiology.

[32]  J. Jansen,et al.  Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation , 2004, Intensive Care Medicine.

[33]  N. Secher,et al.  Monitoring of peri‐operative fluid administration by individualized goal‐directed therapy , 2007, Acta anaesthesiologica Scandinavica.