Computer Simulations of Speckle in B-Scan Images

The granularity or speckle in medical ultrasound images tends to mask the presence of small lesions. As well, artifactual filling in of anechoic regions such as cysts, reduces the diagnostic potential of the images. These effects depend not only on the acoustic properties of the tissue but also are strongly influenced by the imaging system, especially the transducer geometry. To study the effect of the transducer on the final B-scan image, a computer model has been developed simulating the interaction of ultrasound with a simple scattering medium. This model, incorporating the position dependence of the point response of the transducer, is based on single scattering from a collection of points positioned randomly in a three-dimensional volume. Using this approach, B-scan images showing speckle have been generated for different transducer geometries. Inclusion of a 2.6 mm void mimicking a cyst within the three-dimensional scattering volume has allowed us to predict the cyst contrast in the image for the different transducer systems. Experimental B-scan images of a scattering phantom were obtained using the different pulse echo systems. Quantitative assessment using first and second order statistics of the images shows good agreement between experiment and theory.

[1]  F. Foster,et al.  Acoustic Fields of Conical Radiators , 1982, IEEE Transactions on Sonics and Ultrasonics.

[2]  Gary H. Glover,et al.  Textural Variations in B-Mode Ultrasonography: A Stochastic Model , 1981 .

[3]  M S Patterson,et al.  The improvement and quantitative assessment of B-mode images produced by an annular array/cone hybrid. , 1983, Ultrasonic imaging.

[4]  P. Stepanishen Transient Radiation from Pistons in an Infinite Planar Baffle , 1970 .

[5]  C. Burckhardt Speckle in ultrasound B-mode scans , 1978, IEEE Transactions on Sonics and Ultrasonics.

[6]  H. E. Melton,et al.  Real Time Speckle Reduction in B-Mode Images , 1979 .

[7]  F. Foster,et al.  Ultrasound Transducers for Pulse-Echo Medical Imaging , 1983, IEEE Transactions on Biomedical Engineering.

[8]  W. Garrett,et al.  Ultrasonic Film Echoscopy for Placental Localization , 1972, The Australian & New Zealand journal of obstetrics & gynaecology.

[9]  G. Kossoff,et al.  Principles and classification of soft tissues by grey scale echography. , 1976, Ultrasound in medicine & biology.

[10]  R. J. Dickinson,et al.  A Computer Model for Speckle in Ultrasound Images: Theory and Application , 1982 .

[11]  R. Dickinson Reduction of Speckle in Ultrasound B-Scans by Digital Processing , 1982 .

[12]  F. Dunn,et al.  Letter: Correlation of echographic visualizability of tissue with biological composition and physiological state. , 1973, The Journal of the Acoustical Society of America.

[13]  Mauri Luukkala,et al.  The impulse response and pressure nearfield of a curved ultrasonic radiator , 1976 .

[14]  A. J. Hayman,et al.  Observations of the propagation of very short ultrasonic pulses and their reflection by small targets , 1978 .

[15]  M Arditi,et al.  Transient fields of concave annular arrays. , 1981, Ultrasonic imaging.

[16]  J C Gore,et al.  Ultrasonic backscattering from human tissue: a realistic model. , 1977, Physics in medicine and biology.

[17]  J. Goodman Statistical Properties of Laser Speckle Patterns , 1963 .

[18]  J. Goodman Some fundamental properties of speckle , 1976 .

[19]  F. L. Thurstone,et al.  Acoustic Speckle: Theory and Experimental Analysis , 1979 .

[20]  J C Bamber,et al.  Ultrasonic B-scanning: a computer simulation , 1980, Physics in medicine and biology.

[21]  Melvin Linzer,et al.  Ultrasonic tissue characterization II , 1979 .

[22]  M. Berry,et al.  Random noise in ultrasonic echoes diffracted by blood , 1974 .

[23]  F. S. Foster,et al.  The Conical Scanner: A Two Transducer Ultrasound Scatter Imaging Technique , 1981 .

[24]  J.W. Hunt,et al.  An Annular Array System for High Resolution Breast Echography , 1982 .

[25]  R C Chivers,et al.  The scattering of ultrasound by human tissues--some theoretical models. , 1977, Ultrasound in medicine & biology.

[26]  F. Foster,et al.  The Improvement and Quantitative Assessment of B-Mode Images Produced by an Annular Array/Cone Hybrid , 1983 .

[27]  R. F. Wagner,et al.  Statistics of Speckle in Ultrasound B-Scans , 1983, IEEE Transactions on Sonics and Ultrasonics.

[28]  M S Patterson,et al.  The conical scanner: a two transducer ultrasound scatter imaging technique. , 1981, Ultrasonic imaging.