Improved Grid Synchronization Control of Doubly Fed Induction Generator Under Unbalanced Grid Voltage

An improved grid synchronization control scheme of the wind energy conversion system based on the doubly fed induction generator (DFIG) under unbalanced grid voltage is proposed in this paper. In both the positive and negative sequence models, respectively, the degrees of relevancy among rotor voltages, rotor currents, and stator voltages are calculated using the relative gain array (RGA) methodology. According to the analysis results of RGA, the main controller is designed to control positive sequence stator voltages directly with positive sequence rotor voltages, and the auxiliary controller is designed to control negative sequence stator voltages directly with negative sequence rotor voltages. Hence, the rotor current control loops are eliminated, which simplifies the structure of the controller. Simulation and hardware experimental results validate that the improved control scheme effectively controls stator voltages of the DFIG to accurately follow unbalanced grid voltage and, hence, avoids current, torque, and power impacts to both the DFIG and the grid at the time of connecting.

[1]  Yongdong Li,et al.  Vector control and synchronization of doubly fed induction wind generator system , 2004, The 4th International Power Electronics and Motion Control Conference, 2004. IPEMC 2004..

[2]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[3]  T. Thiringer,et al.  Evaluation of current control methods for wind turbines using doubly-fed induction machines , 2005, IEEE Transactions on Power Electronics.

[4]  Vadim I. Utkin,et al.  Sliding mode control in electromechanical systems , 1999 .

[5]  Jie Wu,et al.  Grid Synchronization of Doubly-fed Induction Generator Using Integral Variable Structure Control , 2009, IEEE Transactions on Energy Conversion.

[6]  N. Mohan,et al.  Control of a Doubly Fed Induction Wind Generator Under Unbalanced Grid Voltage Conditions , 2007, IEEE Transactions on Energy Conversion.

[7]  Mohammed Chadli,et al.  Multivariable control systems - an engineering approach , 2003, Autom..

[8]  R. W. De Doncker,et al.  Doubly fed induction generator systems for wind turbines , 2002 .

[9]  Eduard Muljadi,et al.  Understanding the unbalanced-voltage problem in wind turbine generation , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[10]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[11]  S. Arnalte,et al.  Direct Power Control Applied to Doubly Fed Induction Generator Under Unbalanced Grid Voltage Conditions , 2008, IEEE Transactions on Power Electronics.

[12]  Lie Xu,et al.  Direct active and reactive power control of DFIG for wind energy generation , 2006, IEEE Transactions on Energy Conversion.

[13]  Longya Xu,et al.  Torque and reactive power control of a doubly-fed induction machine by position sensorless scheme , 1994, Proceedings of 1994 IEEE Industry Applications Society Annual Meeting.

[14]  J.A. Ferreira,et al.  Operation of Grid-Connected DFIG Under Unbalanced Grid Voltage Condition , 2009, IEEE Transactions on Energy Conversion.

[15]  Antti J. Koivo,et al.  Nonlinear predictive control with application to manipulator with flexible forearm , 1999, IEEE Trans. Ind. Electron..

[16]  Hong-Seok Song,et al.  Dual current control scheme for PWM converter under unbalanced input voltage conditions , 1999, IEEE Trans. Ind. Electron..

[17]  Jie Wu,et al.  Integral Sliding-Mode Direct Torque Control of Doubly-Fed Induction Generators Under Unbalanced Grid Voltage , 2010, IEEE Transactions on Energy Conversion.

[18]  S. Arnalte,et al.  Direct Torque Control of a Doubly-Fed Induction Generator for Variable Speed Wind Turbines , 2002 .

[19]  S. L. Ho,et al.  Direct Voltage Control for Grid Synchronization of Doubly-fed Induction Generators , 2008 .

[20]  J. M. Kauffmann,et al.  Double-fed induction machine: converter optimisation and field oriented control without position sensor , 1998 .

[21]  Lie Xu,et al.  Coordinated Control of DFIG's Rotor and Grid Side Converters During Network Unbalance , 2008, IEEE Transactions on Power Electronics.

[22]  Dongwook Kim,et al.  Control method of a doubly-fed induction generator with automatic grid synchronization , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.