Development of 3D space-sharing interface using augmented reality technology for domestic tele-echography

We propose a domestic tele-echography system linking between the patient's home and a hospital because of the demand due to increase in the number of patients by aging society and recent progress in portable echography enabled us to develop this system. In previous researches three-dimensional position of the ultrasound probe was difficult to specify because a remote doctor observe the patient through a video camera. Therefore we have developed a reproduction system of the probe position and angle using the ARToolKit and GUI interface using OpenGL. Only an USB camera and two markers for the body surface and the probe are necessary to memorize and transfer three-dimensional position of the probe. We have also designed a doctor side interface including echogram, patient scene and CG to instruct probe operation. As a result of evaluation experiments, guided position was satisfied to reproduce the echogram for diagnosis.

[1]  Yusuke Aoki,et al.  Development of graphical user interface to control remote probe by reflecting contact force on body surface for tele-echography system , 2009 .

[2]  Mark Billinghurst,et al.  The use of dense stereo range data in augmented reality , 2002, Proceedings. International Symposium on Mixed and Augmented Reality.

[3]  Herbert Edelsbrunner,et al.  Geometry and Topology for Mesh Generation , 2001, Cambridge monographs on applied and computational mathematics.

[4]  Tomohiro Kuroda,et al.  A tele-instruction system for ultrasound probe operation based on shared AR technology , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  Ryutarou Ohbuchi,et al.  Merging virtual objects with the real world: seeing ultrasound imagery within the patient , 1992, SIGGRAPH.

[6]  Henry Fuchs,et al.  Augmented reality guidance for needle biopsies: An initial randomized, controlled trial in phantoms , 2002, Medical Image Anal..

[7]  Matthew Lyon,et al.  Ultrasound image transmission via camera phones for overreading. , 2005, The American journal of emergency medicine.

[8]  Ralf Dörner,et al.  Accuracy in optical tracking with fiducial markers: an accuracy function for ARToolKit , 2004, Third IEEE and ACM International Symposium on Mixed and Augmented Reality.

[9]  Hirokazu Kato,et al.  Marker tracking and HMD calibration for a video-based augmented reality conferencing system , 1999, Proceedings 2nd IEEE and ACM International Workshop on Augmented Reality (IWAR'99).

[10]  Herbert Edelsbrunner,et al.  Geometry and Topology for Mesh Generation , 2001, Cambridge monographs on applied and computational mathematics.

[11]  Herbert Edelsbrunner,et al.  Geometry and Topology for Mesh Generation (Cambridge Monographs on Applied and Computational Mathematics) , 2006 .