Twente Optical Perfusion Camera: system overview and performance for video rate laser Doppler perfusion imaging.

We present the Twente Optical Perfusion Camera (TOPCam), a novel laser Doppler Perfusion Imager based on CMOS technology. The tissue under investigation is illuminated and the resulting dynamic speckle pattern is recorded with a high speed CMOS camera. Based on an overall analysis of the signal-to-noise ratio of CMOS cameras, we have selected the camera which best fits our requirements. We applied a pixel-by-pixel noise correction to minimize the influence of noise in the perfusion images. We can achieve a frame rate of 0.2 fps for a perfusion image of 128x128 pixels (imaged tissue area of 7x7 cm2) if the data is analyzed online. If the analysis of the data is performed offline, we can achieve a frame rate of 26 fps for a duration of 3.9 seconds. By reducing the imaging size to 128x16 pixels, this frame rate can be achieved for up to half a minute. We show the fast imaging capabilities of the system in order of increasing perfusion frame rate. First the increase of skin perfusion after application of capsicum cream, and the perfusion during an occlusion-reperfusion procedure at the fastest frame rate allowed with online analysis is shown. With the highest frame rate allowed with offline analysis, the skin perfusion revealing the heart beat and the perfusion during an occlusion-reperfusion procedure is presented. Hence we have achieved video rate laser Doppler perfusion imaging.

[1]  N. McLean,et al.  New laser Doppler scanner, a valuable adjunct in burn depth assessment. , 1993, Burns : journal of the International Society for Burn Injuries.

[2]  John Tulip,et al.  Laser Doppler imaging of burn scars: a comparison of wavelength and scanning methods. , 2003, Burns : journal of the International Society for Burn Injuries.

[3]  Haiying Cheng,et al.  Simplified laser-speckle-imaging analysis method and its application to retinal blood flow imaging. , 2007, Optics letters.

[4]  Ton G. van Leeuwen,et al.  Laser Doppler Perfusion Imaging with a high-speed CMOS-camera , 2007, European Conference on Biomedical Optics.

[5]  Wiendelt Steenbergen,et al.  Prediction of the photodetector signal generated by Doppler-induced speckle fluctuations: theory and some validations , 1999 .

[6]  J D Briers,et al.  Capillary Blood Flow Monitoring Using Laser Speckle Contrast Analysis (LASCA). , 1999, Journal of biomedical optics.

[7]  J. Briers,et al.  Flow visualization by means of single-exposure speckle photography , 1981 .

[8]  J. David Briers,et al.  Laser Doppler and time-varying speckle: a reconciliation , 1996 .

[9]  J. Tulip,et al.  A comparison of two laser-based methods for determination of burn scar perfusion: laser Doppler versus laser speckle imaging. , 2005, Burns : journal of the International Society for Burn Injuries.

[10]  Gerhard Rakhorst,et al.  Diffusion model for iontophoresis measured by laser-Doppler perfusion flowmetry, applied to normal and preeclamptic pregnancies. , 2007, Journal of biomedical optics.

[11]  R. Nossal,et al.  Model for laser Doppler measurements of blood flow in tissue. , 1981, Applied optics.

[12]  Wiendelt Steenbergen,et al.  Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor. , 2002, Optics letters.

[13]  Theo Lasser,et al.  High-speed laser Doppler perfusion imaging using an integrating CMOS image sensor. , 2005, Optics express.

[14]  H. Martin,et al.  Laser Doppler imaging of paediatric burns: burn wound outcome can be predicted independent of clinical examination. , 2006, Burns : journal of the International Society for Burn Injuries.

[15]  Ton G. van Leeuwen,et al.  Connecting laser Doppler perfusion imaging and laser speckle contrast analysis , 2008, SPIE BiOS.

[16]  F. W. Kloppenberg,et al.  Perfusion of burn wounds assessed by laser doppler imaging is related to burn depth and healing time. , 2001, Burns : journal of the International Society for Burn Injuries.

[17]  Toshimitsu Asakura,et al.  Bio-speckle phenomena and their application to the evaluation of blood flow , 1991 .

[18]  J. Briers,et al.  Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. , 2001, Physiological measurement.

[19]  Q. Luo,et al.  Modified laser speckle imaging method with improved spatial resolution. , 2003, Journal of biomedical optics.

[20]  Karin Wårdell,et al.  Laser Doppler perfusion imaging , 1992 .

[21]  A. Humeau,et al.  Simplified model of laser Doppler signals during reactive hyperaemia , 2006, Medical and Biological Engineering and Computing.

[22]  Theo Lasser,et al.  Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera. , 2005, Optics express.

[23]  Ton van Leeuwen,et al.  Review of laser speckle contrast techniques for visualizing tissue perfusion , 2008, Lasers in Medical Science.

[24]  Stephen P Morgan,et al.  Laser Doppler blood flow complementary metal oxide semiconductor imaging sensor with analog on-chip processing. , 2008, Applied optics.

[25]  W Steenbergen,et al.  Measurement of depth of burns by laser Doppler perfusion imaging. , 2001, Burns : journal of the International Society for Burn Injuries.

[26]  C. Skouras,et al.  An audit of the use of laser Doppler imaging (LDI) in the assessment of burns of intermediate depth. , 2001, Burns : journal of the International Society for Burn Injuries.