Interferometric differentiation between resonant coherent anti-Stokes Raman scattering and nonresonant four-wave-mixing processes

A major impediment to the use of coherent anti-Stokes Raman scattering (CARS) to identify biological molecules is that the illumination levels required to produce a measurable signal often also produce significant nonresonant background from the medium, especially from water. We present a method of nonlinear interferometry to differentiate between which components of the anti-Stokes signal are resonant and nonresonant. The technique takes advantage of the persistence of intermediate states involved in the resonant process. This method is applicable to most existing pulsed CARS illumination methods and provides for identification of resonant CARS. We demonstrate the method by examining the signals produced by acetone, which exhibits resonance, and water, which does not.

[1]  M D Duncan,et al.  Scanning coherent anti-Stokes Raman microscope. , 1982, Optics letters.

[2]  Kelly P. Knutsen,et al.  High spectral resolution multiplex CARS spectroscopy using chirped pulses , 2004 .

[3]  Yaron Silberberg,et al.  Single-pulse phase-contrast nonlinear Raman spectroscopy. , 2002, Physical review letters.

[4]  F. Kamga,et al.  Pulse-sequenced coherent anti-Stokes Raman scattering spectroscopy: a method for suppression of the nonresonant background. , 1980, Optics letters.

[5]  Yaron Silberberg,et al.  Femtosecond phase-and-polarization control for background-free coherent anti-Stokes Raman spectroscopy. , 2003, Physical review letters.

[6]  M M Murnane,et al.  Simplified setup for high-resolution spectroscopy that uses ultrashort pulses. , 2003, Optics letters.

[7]  R. Leonhardt,et al.  Terahertz quantum beats in molecular liquids , 1987 .

[8]  Gengfeng Zheng,et al.  Laser-scanning coherent anti-Stokes Raman scattering microscopy and applications to cell biology. , 2002, Biophysical journal.

[9]  Manuel Joffre,et al.  Linear techniques of phase measurement by femtosecond spectral interferometry for applications in spectroscopy , 1995 .

[10]  Jun Ye,et al.  High-sensitivity coherent anti-Stokes Raman scattering microscopy with two tightly synchronized picosecond lasers. , 2002, Optics letters.

[11]  Andreas Volkmer,et al.  Time-resolved coherent anti-Stokes Raman scattering microscopy: Imaging based on Raman free induction decay , 2002 .

[12]  M. D. Levenson,et al.  Background suppression in coherent Raman spectroscopy , 1976 .

[13]  Juleon M. Schins,et al.  Direct measurement of chain order in single phospholipid mono- and bilayers with multiplex CARS , 2004 .

[14]  D. Brady,et al.  Time-of-flight cross correlation on a detector array for ultrafast packet detection. , 1993, Optics letters.

[15]  S. Boppart,et al.  Nonlinear optical contrast enhancement for optical coherence tomography. , 2003, Optics express.

[16]  X. Xie,et al.  Polarization coherent anti-Stokes Raman scattering microscopy. , 2001, Optics letters.

[17]  U. I. Urbana-Champaign,et al.  Non-linear interferometric vibrational imaging , 2003, Conference on Lasers and Electro-Optics, 2003. CLEO '03..

[18]  Andreas Volkmer,et al.  Vibrational Imaging with High Sensitivity via Epidetected Coherent Anti-Stokes Raman Scattering Microscopy , 2001 .

[19]  Yaron Silberberg,et al.  Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy , 2002, Nature.