Computer-controlled heart rate increase by isoproterenol infusion: mathematical modeling of the system.

The purpose of this study was mathematical modeling of the heart rate (HR) response to isoproterenol (Iso) infusion. We developed a computerized system for the controlled increase of HR by Iso, based on a modified proportional-integral controller. HR was measured in conscious, freely moving rats. We found that the steady-state HR can be described as a hyperbolic power function of the steady-state Iso flow rate. This dependence was coupled with a first-order difference equation to form a pharmacodynamic model that reliably describes the relationship between HR and Iso flow for any arbitrary form of Iso flow function. In simulation studies, we showed that the model continued to follow the HR curve from real-time experiments far beyond the initial "learning interval" from which its parameters were calculated. Our results suggest that the predictive ability and the simplicity of calculating the parameters render this pharmacodynamic model appropriate for use within future advanced, model-based, adaptive control systems and as a part of larger cardiovascular models.

[1]  D. Bogen,et al.  The Use of Computers for Controlling the Delivery of Anesthesia , 1992, Anesthesiology.

[2]  I. Kopin,et al.  Hyperresponsivitiy of spontaneously hypertensive rat to indirect measurement of blood pressure. , 1978, The American journal of physiology.

[3]  Ben-Zion Bobrovsky,et al.  Heart rate control by the computerized infusion of isoproterenol , 1997, Computers in Cardiology 1997.

[4]  J. Padbury,et al.  Dobutamine pharmacokinetics and pharmacodynamics in pediatric intensive care patients , 1992, Critical care medicine.

[5]  W.L. van Meurs,et al.  Pharmacokinetic-pharmacodynamic model for educational simulations , 1998, IEEE Transactions on Biomedical Engineering.

[6]  C. Chiang,et al.  Sustained Atrial Tachycardia in Adult Patients: Electrophysiological Characteristics, Pharmacological Response, Possible Mechanisms, and Effects of Radiofrequency Ablation , 1994, Circulation.

[7]  H. Kaufman,et al.  Multiple-model adaptive predictive control of mean arterial pressure and cardiac output , 1992, IEEE Transactions on Biomedical Engineering.

[8]  K. Mcdonough,et al.  Cardiac function and chronotropic sensitivity to beta-adrenergic stimulation in sepsis. , 1986, American Journal of Physiology.

[9]  F. Nielsen‐Kudsk,et al.  Myocardial pharmacodynamics of dopamine, dobutamine, amrinone and isoprenaline compared in the isolated rabbit heart. , 1986, European journal of pharmacology.

[10]  John D'Azzo,et al.  Linear Control System Analysis and Design: Conventional and Modern , 1977 .

[11]  D A Linkens,et al.  Computer control systems and pharmacological drug administration: a survey. , 1990, Journal of medical engineering & technology.

[12]  P. Flanagan,et al.  Risk factors for syncope recurrence after a positive tilt-table test in patients with syncope. , 1996, Circulation.

[13]  Rob J. Roy,et al.  Modeling the hemodynamic response to dopamine in acute heart failure , 1988, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  D. Noe,et al.  A pharmacokinetic–pharmacodynamic model of heart rate during cocaine administration in humans , 1991, Clinical pharmacology and therapeutics.

[15]  S. Eliash,et al.  The muscarinic cholinergic receptors in the posterior hypothalamus of hypertensive and normotensive rats. , 1982, European journal of pharmacology.

[16]  K. Stangl,et al.  Development of a closed-loop pacemaker controller regulating mixed venous oxygen saturation level , 1988, IEEE Transactions on Biomedical Engineering.

[17]  H. Chizeck,et al.  Closed-loop drug infusion for control of heart-rate trajectory in pharmacological stress tests , 1997, IEEE Transactions on Biomedical Engineering.

[18]  R. Jelliffe,et al.  Computer-controlled administration of cardiovascular drugs. , 1983, Progress in cardiovascular diseases.