AbstractThis paper discusses the impact of hinged connectors (a common connection in folding structures) on the behavior of sandwich panels (with fiber-reinforced polymer faces and foam core). A sandwich panel is subjected to uniform loading and tested when restrained by hinged connectors in compression and in tension. The measured results are compared to finite-element numerical models, focusing on global behavior (displacements and strains at center) and local behavior (strains near connectors). Parametric studies using these validated numerical models investigate the impact of the number, size, and relative placement of hinged connectors. These studies culminate in guidelines for the design of structures comprised of hinged, folding panels. Ultimately, this paper addresses a research gap in understanding the behavior of sandwich panels connected by hinges.

[1]  Jandro L. Abot,et al.  Fabrication, testing and analysis of composite sandwich beams , 2000 .

[2]  Carmine Pappalettere,et al.  An experimental investigation of static and fatigue behaviour of sandwich composite panels joined by fasteners , 2001 .

[3]  M. B. Ioannidis,et al.  On the crushing response of composite sandwich panels subjected to edgewise compression: experimental , 2005 .

[4]  Ashley P. Thrall,et al.  Parametric Study of the Effect of Hinged Connectors on the Behavior of Origami-Inspired Structures Comprised of Sandwich Panels , 2015 .

[5]  Ashley P. Thrall,et al.  Bascule shelters: A novel erection strategy for origami-inspired deployable structures , 2014 .

[6]  H. Wadley,et al.  Compressive response of glass fiber composite sandwich structures , 2013 .

[7]  DawoodMina,et al.  Connection development and in-plane response of glass fiber reinforced polymer sandwich panels with reinforced cores1 , 2013 .

[8]  Bernardo Zuccarello,et al.  Experimental and numerical evaluation of the mechanical behaviour of GFRP sandwich panels , 2007 .

[9]  Thiru Aravinthan,et al.  Flexural behaviour of structural fibre composite sandwich beams in flatwise and edgewise positions , 2010 .

[10]  Raffaele Landolfo,et al.  Mechanical fasteners for cladding sandwich panels:: Interpretative models for shear behaviour , 1999 .

[11]  B. Castanié,et al.  Experimental and Numerical Analysis of Inserts in Sandwich Structures , 2005 .

[12]  Sebastian Heimbs,et al.  Failure behaviour of honeycomb sandwich corner joints and inserts , 2009 .

[13]  Lorna J. Gibson,et al.  Size effects in metallic foam core sandwich beams , 2002 .

[14]  G. De Matteis,et al.  Structural behaviour of sandwich panel shear walls: An experimental analysis , 1999 .