Computational analysis of daylight harvesting scheme in an office building in Mumbai

Designing a building with maximum utilization of daylight and use of energy efficient luminaires will reduce the cost of energy use. In the present study, by means of computer simulations using RELUX software, the interaction between natural and artificial light and the related illumination conditions expected in a commercial office building in Mumbai, India have been simulated and analyzed. In this way, it was possible to evaluate the relevant loads for artificial illumination that has been considered not as the principal but a complementary light source. The main goal of this study is to show the potential of drastically reducing the electrical energy consumptions for illumination, by adopting day lighting harvesting solutions. Comparison were done using two different lighting schemes one with Fluorescent Luminaires and without daylight harvesting and other one with LED fixtures with daylight harvesting using combined occupancy and daylight dimming sensors. With the latter scheme a saving of 80% can be achieved on energy and operating costs for a period over 25 years.

[1]  G. W. Larson,et al.  Rendering with radiance - the art and science of lighting visualization , 2004, Morgan Kaufmann series in computer graphics and geometric modeling.

[2]  Martin K T Wu BSc MSc CEng Mhkie Miee Mcibse,et al.  Office Lighting Retrofit Using T5 Fluorescent Lamps and Electronic Ballasts , 2003 .

[3]  Gregory M. Maxwell,et al.  An empirical validation of the daylighting algorithms and associated interactions in building energy simulation programs using various shading devices and windows , 2007 .

[4]  Nancy C. Ruck International Energy Agency's Solar Heating and Cooling Task 31, ‘Daylighting Buildings in the 21st Century’ , 2006 .

[5]  Danny H.W. Li,et al.  Evaluation of lighting performance in office buildings with daylighting controls , 2001 .

[6]  G. N. Tiwari,et al.  A model for estimation of daylight factor for skylight: An experimental validation using pyramid shape skylight over vault roof mud-house in New Delhi (India) , 2009 .

[7]  Aris Tsangrassoulis,et al.  Quantifying energy savings in daylight responsive systems : The role of dimming electronic ballasts , 2008 .

[8]  V I George,et al.  Robust control and optimisation of energy consumption in daylight—artificial light integrated schemes , 2008 .

[9]  Danny H.W. Li,et al.  Lighting and energy performance for an office using high frequency dimming controls , 2006 .

[10]  Danny H.W. Li,et al.  Energy and cost analysis of semi-transparent photovoltaic in office buildings , 2009 .

[11]  Danny H.W. Li,et al.  Lighting and cooling energy consumption in an open-plan office using solar film coating , 2008 .

[12]  Tm Chung,et al.  Potential energy saving for a side-lit room using daylight-linked fluorescent lamp installations , 2002 .

[13]  Leyla Dokuzer Öztürk,et al.  Determination of Energy Losses in Lighting in Terms of Good Vision Efficiency , 2008 .