Coherent x-ray scattering for discriminating bio-compatible materials in tissue scaffolds

It has been shown that coherently scattered x-rays can be used to discriminate and identify specific components in a mixture of materials. To assess the feasibility of using coherent x-ray scatter (CXS) to characterize the material components within tissue scaffolds, we studied the CXS properties of the bio-compatible materials of polymers (polypropylene fumarate, polycaprolactone, epoxy, etc.), sugar and salt solutions at different concentration, and complex materials consisting of more than one polymer. We also investigated the effects of x-ray spectra on the CXS functions of polymers by measuring them with different x-ray source anodes. It is shown that the synthesized polymers with different portions of base polymers can be characterized with CXS. The polymerization process does not significantly change the CXS characteristics of the measured polymers. When protein is denatured, no substantial change in scatter was detected. Solutions of different concentration can be characterized and quantified by the CXS features corresponding to the solutes. The difference among CXS of solutions of different concentration makes it possible to image and trace fluids and their concentration changes in tissues or scaffolds. Our results show that CXS of complex specimens can be decomposed with the scatter functions of the component materials. By simulating a tissue scaffold with a phantom with several bio-compatible materials, we demonstrated that significant contrast can be achieved at proper scatter angles by measuring the coherent x-ray scatter, despite the low attenuation-based contrast between them. We conclude that use of x-ray scatter makes it possible to track and map the fate (e.g., its breakdown and/or removal) of specific components within tissue scaffolds.

[1]  Paul C. Johns,et al.  Medical x-ray imaging with scattered photons , 2017, Other Conferences.

[2]  Steven M. Jorgensen,et al.  High resolution x-ray imaging of dynamic solute transport in cyclically deformed porous tissue scaffolds , 2008, SPIE Medical Imaging.

[3]  A. Barnes,et al.  X-ray and neutron scattering studies of the hydration structure of alkali ions in concentrated aqueous solutions. , 2006, Biophysical chemistry.

[4]  Ian A Cunningham,et al.  Bone-composition imaging using coherent-scatter computed tomography: assessing bone health beyond bone mineral density. , 2006, Medical physics.

[5]  Michael J Yaszemski,et al.  Synthesis and characterizations of biodegradable and crosslinkable poly(epsilon-caprolactone fumarate), poly(ethylene glycol fumarate), and their amphiphilic copolymer. , 2006, Biomaterials.

[6]  S J Wilkinson,et al.  A preliminary study of breast cancer diagnosis using laboratory based small angle x-ray scattering , 2005, Physics in medicine and biology.

[7]  T. Hefferan,et al.  Synthesis, material properties, and biocompatibility of a novel self-cross-linkable poly(caprolactone fumarate) as an injectable tissue engineering scaffold. , 2005, Biomacromolecules.

[8]  Saeed Sarkar,et al.  Application of Small Angle X-ray Scattering (SAXS) for Differentiation between Normal and Cancerous Breast Tissue , 2005, International journal of medical sciences.

[9]  P. C. Johns,et al.  Measurement of coherent x-ray scatter form factors for amorphous materials using diffractometers , 2004, Physics in medicine and biology.

[10]  Geoffrey I. Webb,et al.  A Case Study in Feature Invention for Breast Cancer Diagnosis Using X-Ray Scatter Images , 2003, Australian Conference on Artificial Intelligence.

[11]  Michael Grass,et al.  Coherent scatter computed tomography: a novel medical imaging technique , 2003, SPIE Medical Imaging.

[12]  P Suortti,et al.  Small-angle x-ray scattering studies of human breast tissue samples. , 2002, Physics in medicine and biology.

[13]  R. Lopes,et al.  X-ray diffraction microtomography using synchrotron radiation , 2001 .

[14]  M. Paukshto,et al.  Human tissue analysis by small-angle X-ray scattering , 2000 .

[15]  P Suortti,et al.  Feasibility study of x-ray diffraction computed tomography for medical imaging. , 1998, Physics in medicine and biology.

[16]  Ulf Kleuker,et al.  X-ray diffraction computed tomography: a survey and description , 1997, Optics & Photonics.

[17]  U Neitzel,et al.  X-ray diffraction measurements of some plastic materials and body tissues. , 1987, Medical physics.

[18]  U Neitzel,et al.  X-ray diffraction computed tomography. , 1987, Medical physics.

[19]  K. K. W. Siua,et al.  Identifying markers of pathology in SAXS data of malignant tissues of the brain , 2005 .

[20]  G. Truskey,et al.  Transport phenomena in biological systems , 2004 .

[21]  A Fenster,et al.  Tomographic imaging of the angular-dependent coherent-scatter cross section. , 1997, Medical physics.

[22]  I. Gulyi,et al.  Model of the structure of sucrose solutions , 1991 .

[23]  L. Sperling Introduction to physical polymer science , 1986 .