Assessment of wind power penetration level in distribution network with consideration of static, motor and composite loads

The complexity of power systems has increased in recent years due to the operation of existing wind generator closer to their limits, and also due to the diversity of load model. This changing nature of a power system has considerable effect on its dynamic behaviours resulting in dynamic interactions between different power system devices. This paper presents an assessment of wind power penetration in a distribution network, with consideration of a static load, exponential recovery load, motor load and a composite load. Motor loads are assessed with respect to their mechanical loads. The wind farm is represented by a variable-speed inductions generator based on doubly-fed induction generators. A differential algebraic representation is developed; and the study is based on the determination of bifurcation points and validated by time domain simulations. The bifurcation points indicated the load-generator dynamic interaction and the network permissible wind power penetration. A comparison is made in terms of permissible wind penetration. Various simulation results show that addition of exponential recovery load model improves the wind generation margin. However, the induction motor load and composite load model reduce the voltage stability of the wind integrated system. It has been established that the mechanical load of the induction motor which has a strong linear dependence on speed is the most critical load for the wind system.

[1]  Shi Ke-qin,et al.  A New Load Survey Method and Its Application in Component Based Load Modeling , 2010 .

[2]  C. A. Canizares,et al.  Comparative stability analysis of DFIG-based wind farms and conventional synchronous generators , 2011, 2011 IEEE/PES Power Systems Conference and Exposition.

[3]  G.K. Stefopoulos,et al.  Induction Motor Load Dynamics: Impact on Voltage Recovery Phenomena , 2006, 2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition.

[4]  D. Hill,et al.  Modelling and identification of nonlinear dynamic loads in power systems , 1994 .

[5]  D. Hill,et al.  Stability theory for differential/algebraic systems with application to power systems , 1990 .

[6]  Cristina Gonzalez-Moran,et al.  Composite Loads in Stand-Alone Inverter-Based Microgrids—Modeling Procedure and Effects on Load Margin , 2010, IEEE Transactions on Power Systems.

[7]  F. Milano Assessing adequate voltage stability analysis tools for networks with high wind power penetration , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[8]  N. Mithulananthan,et al.  Impact of composite loads on dynamic loadability of emerging distribution systems , 2011, AUPEC 2011.

[9]  Kavitha Busi,et al.  Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer during Symmetrical and Asymmetrical Grid Faults , 2013 .

[10]  Nguyen Tung Linh Voltage stability analysis of grids connected wind generators , 2009, 2009 4th IEEE Conference on Industrial Electronics and Applications.

[11]  Yongchuan Zhang,et al.  Investigation of Wind Farm on Power System Voltage Stability Based on Bifurcation Theory , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[12]  Yongchuan Zhang,et al.  Small signal stability analysis of large scale variable speed wind turbines integration , 2008, 2008 International Conference on Electrical Machines and Systems.

[13]  G.T. Heydt,et al.  Composite neural network load models for power system stability analysis , 2004, IEEE PES Power Systems Conference and Exposition, 2004..