A 40-100 MHz B-scan ultrasound backscatter microscope for skin imaging.

There is a growing interest in high resolution, subsurface imaging of cutaneous tissues using higher frequency ultrasound, and several commercial systems have been developed recently which operate at 20 MHz. Some of the possible applications of higher frequency skin imaging include tumour staging, boundary definition, and studies of the response of tumours to therapy, investigations of inflammatory skin conditions such as psoriasis and eczema, and basic studies of skin aging, sun damage and the effects of irritants. Investigation of these areas is quite new, and the role of ultrasound skin imaging is continuing to evolve. Lateral resolution in the 20 MHz imaging systems ranges from 200 to 300 microns, which limits imaging applications to cutaneous structures which are relatively large in size. In this paper, a real-time ultrasound backscatter microscope (UBM) for skin imaging is described which operates in the 40-100 MHz range, providing axial resolution between 17 and 30 microns and lateral resolution between 33 and 94 microns. This improvement in resolution over current skin ultrasound systems should prove useful in determining the margins of small skin lesions, and in obtaining more precise, in vivo skin thickness measurements to characterize nonmalignant skin disease. Example images of normal skin, seborrhoeic keratosis and malignant melanoma illustrate the imaging potential of this system.

[1]  D. Miller,et al.  Determining skin thickness with pulsed ultra sound. , 1979, The Journal of investigative dermatology.

[2]  O. Kolosov,et al.  The use of acoustic microscopy for biological tissue characterization. , 1987, Ultrasound in medicine & biology.

[3]  R.W.B. Stephens,et al.  IEEE ultrasonics symposium , 1972 .

[4]  F. Foster,et al.  Principles and applications of ultrasound backscatter microscopy , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  J Driller,et al.  Three-dimensional imaging for diagnostic ultrasound in dermatology. , 1993, Journal of the American Academy of Dermatology.

[6]  J W Hunt,et al.  Measurement of the ultrasonic properties of vascular tissues and blood from 35-65 MHz. , 1991, Ultrasound in medicine & biology.

[7]  F. Foster,et al.  Fabrication of high frequency spherically shaped ceramic transducers , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  F. Foster,et al.  A 100 MHz B-scan ultrasound backscatter microscope. , 1989, Ultrasonic imaging.

[9]  F Patat,et al.  High-resolution real-time ultrasonic scanner. , 1992, Ultrasound in medicine & biology.

[10]  F. Lizzi,et al.  DIAGNOSTIC HIGH‐RESOLUTION ULTRASOUND IN DERMATOLOGY , 1993, International journal of dermatology.

[11]  Helmut Ermert,et al.  In vivo ultrasound biomicroscopy , 1993 .

[12]  J C Bamber,et al.  High frequency, high resolution B‐scan ultrasound in the assessment of skin tumours , 1993, The British journal of dermatology.

[13]  W.B. Taylor,et al.  A 100 MHz B-Scan Ultrasound Backscatter Microscope , 1989 .

[14]  F. Foster,et al.  Ultrasound Transducers for Pulse-Echo Medical Imaging , 1983, IEEE Transactions on Biomedical Engineering.

[15]  D. Perednia,et al.  What dermatologists should know about digital imaging. , 1991, Journal of the American Academy of Dermatology.

[16]  K. Hoffmann,et al.  Ultrasound in Dermatology , 1988 .

[17]  J.W. Hunt,et al.  The design of protection circuitry for high-frequency ultrasound imaging systems , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.