Analysis and optimization of a wire actuated, single effect n-R robotic structure

SUMMARY This paper investigates the kinematics and the optimization of a generic robotic structure composed by N serial rotary joints and actuated with a mono-directional tendon system. In the first part of the paper, the specific case that brought us to develop this study is introduced; the main motivations and the scenario with its specific constraints and design choices have been described. Since a complete and detailed analysis of an n-R serial structure with this kind of characteristics could not be found in the literature, the study of the kinematics and the parameter optimization of such a structure is treated as generally as possible, in order to make the procedure and the results applicable for any similar structure. Finally, in the last part, through the introduction of specific constraints and the definition of the parameters, the general analysis has been applied to the specific case of study: the preliminary study of a finger exoskeleton for an astronaut suit.

[1]  Sadao Kawamura,et al.  Development of an ultrahigh speed robot FALCON using wire drive system , 1995, Proceedings of 1995 IEEE International Conference on Robotics and Automation.

[2]  Francesco Giovacchini,et al.  HANDEXOS: Towards an exoskeleton device for the rehabilitation of the hand , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[3]  Robert G. Bartle,et al.  The Elements of Integration and Lebesgue Measure: Bartle/The Elements , 1995 .

[4]  Carlo Ferraresi,et al.  A new methodology for the determination of the workspace of six-DOF redundant parallel structures actuated by nine wires , 2006, Robotica.

[5]  David Graziosi,et al.  Phase VI Advanced EVA Glove Development and Certification for the International Space Station , 2001 .

[6]  M. Ceccarelli,et al.  Optimality criteria for the design of manipulators , 2008, 2008 IEEE Conference on Robotics, Automation and Mechatronics.

[7]  Carlo Ferraresi,et al.  A new 6-DOF parallel robotic structure actuated by wires: The WiRo-6.3 , 2004 .

[8]  Silvia Appendino,et al.  Stiffness of an EVA glove: objective evaluation and testing procedures , 2013, ICRA 2013.

[9]  Marco Ceccarelli,et al.  An optimum design procedure for both serial and parallel manipulators , 2007 .

[10]  Manfred Hiller,et al.  On design of a redundant wire-driven parallel robot WARP manipulator , 1999, Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C).

[11]  Ramaratnam R Bishu,et al.  The effects of extra vehicular activity (EVA) gloves on human performance , 1995 .

[12]  Shelby Thompson,et al.  Use of Traditional and Novel Methods to Evaluate the Influence of an EVA Glove on Hand Performance , 2010 .

[13]  Marco Ceccarelli,et al.  Fundamentals of Mechanics of Robotic Manipulation , 2004, Mechanisms and Machine Science.

[14]  James S. Albus,et al.  The NIST robocrane , 1993, J. Field Robotics.

[15]  R. Bartle The elements of integration and Lebesgue measure , 1995 .

[16]  Jean-Pierre Merlet,et al.  Kinematics of the wire-driven parallel robot MARIONET using linear actuators , 2008, 2008 IEEE International Conference on Robotics and Automation.

[17]  HyunKi In,et al.  Investigation of friction characteristics of a tendon driven wearable robotic hand , 2010, ICCAS 2010.

[18]  Yoky Matsuoka,et al.  Comparison of control strategies for an EMG controlled orthotic exoskeleton for the hand , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[19]  K. Stürmer,et al.  Morphology of the interphalangeal joint surface and its functional relevance. , 2008, The Journal of hand surgery.

[20]  Giuseppe Carbone,et al.  Grasping in Robotics , 2012 .

[21]  Chin-Shyurng Fahn,et al.  Development of a data glove with reducing sensors based on magnetic induction , 2005, IEEE Transactions on Industrial Electronics.

[22]  Gabriele Vassura,et al.  Comparative evaluation of the selective compliance in elastic joints for robotic structures , 2011, 2011 IEEE International Conference on Robotics and Automation.

[23]  Giuseppe Carlo Calafiore,et al.  Towards a hand exoskeleton for a smart EVA glove , 2010, 2010 IEEE International Conference on Robotics and Biomimetics.

[24]  Jean-Pierre Merlet,et al.  Wrench-Feasible Workspace of Parallel Cable-Driven Mechanisms , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[25]  J N A L Leijnse,et al.  Kinematic evaluation of the finger's interphalangeal joints coupling mechanism--variability, flexion-extension differences, triggers, locking swanneck deformities, anthropometric correlations. , 2010, Journal of biomechanics.

[26]  Jean-Pierre Merlet,et al.  Parallel Robots , 2000 .