Linear and branched polyoxide‐based copolymers: Methods to determine the CMC

Evaluation of the physical–chemical properties of aqueous solutions of nonionic surfactants based on polyoxides can be performed by different methods. Depending on the technique used, there can be a significant variation in the critical micelle concentration (CMC) found. This is related to the sensitivity of the technique regarding the unimers and micelles present in the solution as well as the structure of the surfactant evaluated. In this work, the CMC values of aqueous solutions of linear and branched poly(ethylene oxide-polypropylene oxide) (PEO-PPO) block copolymers were determined by tensiometry, fluorescence, and particle size analysis, using copolymers having adjacent structures (that is, hydrophilic and hydrophobic segments located adjacently in the copolymer) and alternating structures. Tensiometry was used to measure the surface tension as a function of the copolymer concentration in aqueous solution. Fluorescence was used to determine the fluorescence intensity of pyrene to plot the graphs of the I1/I3 and IE/IM relations according to the surfactant concentration. Finally, particle size analysis was used to determine the diffusion coefficient of the particles. The results showed that the fluorescence and particle size techniques provide lower (and mutually concordant) CMC values and can be considered more precise because these methods directly analyze the bulk of the solution. © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2009

[1]  E. Lucas,et al.  Behavior of mixtures of nonionic polyoxide‐based surfactants and their application in the destabilization of oil emulsions , 2007 .

[2]  E. Lucas,et al.  Evaluation of the Physical‐Chemical Properties of Poly(ethylene oxide)‐block‐Poly(propylene oxide) by Different Characterization Techniques , 2007 .

[3]  Tadeusz Dabros,et al.  Effect of EO and PO positions in nonionic surfactants on surfactant properties and demulsification performance , 2005 .

[4]  Koch,et al.  A Study of the Temperature-Dependent Micellization of Pluronic F127. , 1999, Journal of colloid and interface science.

[5]  E. Lucas,et al.  Behavior of aqueous solutions of poly(ethylene oxide-b-propylene oxide) copolymers containing a hydrotropic agent , 1998 .

[6]  E. Lucas,et al.  Phase behavior of aqueous systems containing block copolymers of poly(ethylene oxide) and poly(propylene oxide) , 1997 .

[7]  A. Rennie,et al.  A structural study of mixed micelles containing C16TAB and C12E6 surfactants , 1995 .

[8]  T. A. Hatton,et al.  Temperature Effects on Structural Properties of Pluronic P104 and F108 PEO-PPO-PEO Block Copolymer Solutions , 1995 .

[9]  T. A. Hatton,et al.  Fluorescence probe studies of pluronic copolymer solutions as a function of temperature , 1995 .

[10]  B. Chu Structure and Dynamics of Block Copolymer Colloids , 1995 .

[11]  Karin Schillén,et al.  Micellar Sphere-to-Rod Transition in an Aqueous Triblock Copolymer System. A Dynamic Light Scattering Study of a Translational and Rotational Diffusion , 1994 .

[12]  T. A. Hatton,et al.  Surface Activity of Poly(ethylene oxide)-block-Poly(propylene oxide)-block-Poly(ethylene oxide) Copolymers , 1994 .

[13]  Karin Schillén,et al.  Aggregation of a Poly(ethylene oxide)-Poly(propylene oxide)-Poly(ethylene oxide) Triblock Copolymer in Aqueous Solution Studied using Rayleigh-Brillouin and Dynamic Light Scattering , 1993 .

[14]  Karin Schillén,et al.  Triblock Copolymers in Aqueous Solution Studied by Static and Dynamic Light Scattering and Oscillatory Shear Measurements. The Influence of Relative Block Sizes , 1992 .

[15]  K. N. Prasad,et al.  Surface activity and association of ABA polyoxyethylene—polyoxypropylene block copolymers in aqueous solution , 1979 .