An isolated industrial power system driven by wind-coal power for aluminum productions: A case study of frequency control

Summary form only given. Due to the uneven geographical distribution between load and wind power, currently it is difficult to integrate the large-scale wind power into the State Grid in China. There are significant wind curtailments for wind farms due to system restrictions. This paper proposes a new way of utilizing wind power, i.e. in-situ consumption, as an alternative to the costly development of long-distance transmission of large-scale wind power. Electrolytic aluminum load, which is one of the most typical high energy consuming loads, is employed to absorb the excess wind power in western China. An actual isolated industrial power system for aluminum production driven by wind power and coal-fired power is described. The penetration level of wind power in the isolated power system is up to 48.8%. The power imbalance between generation and load demand caused by wind power fluctuation or the tripping of coal-fired generators can dramatically impact the frequency stability of the isolated power system, which is of small inertia. An on-line identification method of power imbalance based on Wide Area Measurement System (WAMS) is presented. According to the characteristics of the electrolytic aluminum load, a system frequency control method by regulating the bus voltages of aluminum loads to eliminate the power imbalance is introduced. The simulation is done in Real Time Digital Simulator (RTDS) and the results verify the validity of the proposed frequency control method.

[1]  Evangelos Rikos,et al.  Stability and Power Quality Issues in Microgrids Under Weather Disturbances , 2008, IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing.

[2]  Josua P. Meyer,et al.  Feasibility study of a wind-pv-diesel hybrid power system for a village , 2012 .

[3]  Frieder Borggrefe,et al.  The potential of demand-side management in energy-intensive industries for electricity markets in Germany , 2011 .

[4]  Jianxun Qi,et al.  Small wind power in China: Current status and future potentials , 2011 .

[5]  S. Santoso,et al.  Augmenting Wind Power Penetration and Grid Voltage Stability Limits Using ESS: Application Design, Sizing, and a Case Study , 2012, IEEE Transactions on Power Systems.

[6]  G. Diaz,et al.  Scheduling of Droop Coefficients for Frequency and Voltage Regulation in Isolated Microgrids , 2010, IEEE Transactions on Power Systems.

[7]  Hao Jiang,et al.  Demand Side Frequency Control Scheme in an Isolated Wind Power System for Industrial Aluminum Smelting Production , 2014 .

[8]  Boon Teck Ooi,et al.  Impacts of Wind Power Minute-to-Minute Variations on Power System Operation , 2008, IEEE Transactions on Power Systems.

[9]  J. L. Aguero,et al.  Aluminum plant. Load modeling for stability studies , 1999, 1999 IEEE Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.99CH36364).

[10]  J. C. Sabonnadiere,et al.  Structural analysis of the electrical system , 1989 .

[11]  O. Arikan,et al.  Power quality assessment of grid-connected wind farms considering regulations in turkey , 2009 .

[12]  Pelin Yilmaz,et al.  A pre-feasibility case study on integrated resource planning including renewables , 2008 .

[13]  Cao Yijia,et al.  Wide-Area Real-Time Dynamic State Estimation Method Based on Hybrid SCADA/PMU Measurements , 2007 .

[14]  Ricardo J. Mantz,et al.  Potential contribution of wind farms to damp oscillations in weak grids with high wind penetration , 2008 .

[15]  Xu Jian,et al.  An Industrial System Powered by Wind and Coal for Aluminum Production: A Case Study of Technical Demonstration and Economic Feasibility , 2012 .

[16]  Les Oxley,et al.  China’s Energy Situation in the New Millennium , 2009 .

[17]  Bin-Kwie Chen,et al.  A Novel Power System Defense Plan to Cope With 30% Wind Power Penetration in the Isolated Penghu System , 2013 .

[18]  Luiz Antonio de Souza Ribeiro,et al.  Isolated Micro-Grids With Renewable Hybrid Generation: The Case of Lençóis Island , 2011, IEEE Transactions on Sustainable Energy.

[19]  Boon-Teck Ooi,et al.  Frequency deviation of thermal power plants due to wind farms , 2006, IEEE Transactions on Energy Conversion.

[20]  Ozan Erdinc,et al.  Optimum design of hybrid renewable energy systems: Overview of different approaches , 2012 .

[21]  Lei Huang,et al.  Optimal PMU Placement Considering Controlled Islanding of Power System , 2014, IEEE Transactions on Power Systems.

[22]  Francisco Javier Ramos-Real,et al.  Electricity generation cost in isolated system: The complementarities of natural gas and renewables in the Canary Islands , 2010 .

[23]  S. Perera,et al.  Open loop response characterisation of an aluminium smelting plant for short time interval feeding , 2009, 2009 IEEE Power & Energy Society General Meeting.

[24]  N.D. Hatziargyriou,et al.  A Stability Algorithm for the Dynamic Analysis of Inverter Dominated Unbalanced LV Microgrids , 2007, IEEE Transactions on Power Systems.

[25]  Jian Zuo,et al.  Performance of wind power industry development in China: A DiamondModel study , 2009 .

[26]  Zhang Da,et al.  Offshore wind energy development in China: Current status and future perspective , 2011 .

[27]  S. Ashok,et al.  Peak Load Management in Electrolytic Process Industries , 2008, IEEE Transactions on Power Systems.

[28]  P. M. Anderson,et al.  A low-order system frequency response model , 1990 .