Neural Interfaces for Intracortical Recording: Requirements, Fabrication Methods, and Characteristics

Implantable neural interfaces for central nervous system research have been designed with wire, polymer, or micromachining technologies over the past 70 years. Research on biocompatible materials, ideal probe shapes, and insertion methods has resulted in building more and more capable neural interfaces. Although the trend is promising, the long-term reliability of such devices has not yet met the required criteria for chronic human application. The performance of neural interfaces in chronic settings often degrades due to foreign body response to the implant that is initiated by the surgical procedure, and related to the probe structure, and material properties used in fabricating the neural interface. In this review, we identify the key requirements for neural interfaces for intracortical recording, describe the three different types of probes—microwire, micromachined, and polymer-based probes; their materials, fabrication methods, and discuss their characteristics and related challenges.

[1]  G. Loeb,et al.  Parylene as a Chronically Stable, Reproducible Microelectrode Insulator , 1977, IEEE Transactions on Biomedical Engineering.

[2]  S. Cogan Neural stimulation and recording electrodes. , 2008, Annual review of biomedical engineering.

[3]  Daryl R. Kipke,et al.  Fabrication of Polymer Neural Probes with Sub-cellular Features for Reduced Tissue Encapsulation , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  Vanessa M. Tolosa,et al.  Insertion of flexible neural probes using rigid stiffeners attached with biodissolvable adhesive. , 2013, Journal of visualized experiments : JoVE.

[5]  J. Skrzypek,et al.  Manufacture of Metal Microelectrodes with the Scanning Electron Microscope , 1975, IEEE Transactions on Biomedical Engineering.

[6]  Chen Hongda,et al.  A novel implantable multichannel silicon-based microelectrode , 2007 .

[7]  Luke P. Lee,et al.  Implantable multichannel electrode array based on SOI technology , 2003 .

[8]  R. Normann,et al.  Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex , 1998, Journal of Neuroscience Methods.

[9]  David J. Anderson,et al.  Novel multi-sided, microelectrode arrays for implantable neural applications , 2011, Biomedical microdevices.

[10]  G. Wallace,et al.  Conducting polymers for neural interfaces: challenges in developing an effective long-term implant. , 2008, Biomaterials.

[11]  Albert P. Pisano,et al.  Silicon-processed microneedles , 1999 .

[12]  Justin C. Sanchez,et al.  Corrosion of tungsten microelectrodes used in neural recording applications , 2011, Journal of Neuroscience Methods.

[13]  Qing Bai,et al.  A high-yield microassembly structure for three-dimensional microelectrode arrays , 2000, IEEE Transactions on Biomedical Engineering.

[14]  C. Marin,et al.  Biocompatibility of Intracortical Microelectrodes: Current Status and Future Prospects , 2010, Front. Neuroeng..

[15]  P. Tresco,et al.  A strategy to passively reduce neuroinflammation surrounding devices implanted chronically in brain tissue by manipulating device surface permeability. , 2015, Biomaterials.

[16]  J. Krüger,et al.  Simultaneous recording with 30 microelectrodes in monkey visual cortex , 2004, Experimental Brain Research.

[17]  A. P. Georgopoulos,et al.  Neuronal population coding of movement direction. , 1986, Science.

[18]  A. Hodgkin,et al.  The effect of sodium ions on the electrical activity of the giant axon of the squid , 1949, The Journal of physiology.

[19]  Nicolas Y. Masse,et al.  Reach and grasp by people with tetraplegia using a neurally controlled robotic arm , 2012, Nature.

[20]  Dim-Lee Kwong,et al.  Development of silicon electrode enhanced by carbon nanotube and gold nanoparticle composites on silicon neural probe fabricated with complementary metal-oxide-semiconductor process , 2014 .

[21]  Ellis Meng,et al.  An Electrochemical Investigation of the Impact of Microfabrication Techniques on Polymer-Based Microelectrode Neural Interfaces , 2015, Journal of Microelectromechanical Systems.

[22]  Emilio Bizzi,et al.  Polymer Fiber Probes Enable Optical Control of Spinal Cord and Muscle Function In Vivo , 2014 .

[23]  David L. Kaplan,et al.  Silk-Backed Structural Optimization of High-Density Flexible Intracortical Neural Probes , 2015, Journal of Microelectromechanical Systems.

[24]  Valentina Castagnola,et al.  Implantable microelectrodes on soft substrate with nanostructured active surface for stimulation and recording of brain activities , 2014 .

[25]  K. Mabuchi,et al.  Parylene flexible neural probes integrated with microfluidic channels. , 2005, Lab on a chip.

[26]  K. Wise,et al.  A high-yield IC-compatible multichannel recording array , 1985, IEEE Transactions on Electron Devices.

[27]  Eric H. Chudler,et al.  A simplified method for manufacturing glass-insulated metal microelectrodes , 1994, Journal of Neuroscience Methods.

[28]  Sylvain Martel,et al.  Microelectrode array fabrication by electrical discharge machining and chemical etching , 2004, IEEE Transactions on Biomedical Engineering.

[29]  Patrick A Tresco,et al.  BBB leakage, astrogliosis, and tissue loss correlate with silicon microelectrode array recording performance. , 2015, Biomaterials.

[30]  J. Donoghue,et al.  Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates , 2013, Journal of neural engineering.

[31]  Daryl R. Kipke,et al.  Wireless implantable microsystems: high-density electronic interfaces to the nervous system , 2004, Proceedings of the IEEE.

[32]  Daryl R. Kipke,et al.  The role of flexible polymer interconnects in chronic tissue response induced by intracortical microelectrodes - a modeling and an in vivo study , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[33]  R. Stein,et al.  Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes. , 2001, Journal of neurophysiology.

[34]  Hargsoon Yoon,et al.  Aligned nanowire growth using lithography-assisted bonding of a polycarbonate template for neural probe electrodes , 2008, Nanotechnology.

[35]  D. Hubel,et al.  Receptive fields of single neurones in the cat's striate cortex , 1959, The Journal of physiology.

[36]  Winnie Jensen,et al.  Interactions among biotic and abiotic factors affect the reliability of tungsten microneedles puncturing in vitro and in vivo peripheral nerves: A hybrid computational approach. , 2016, Materials science & engineering. C, Materials for biological applications.

[37]  Patrick A Tresco,et al.  Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortex. , 2010, Biomaterials.

[38]  Sandeep Negi,et al.  Wafer-scale fabrication of penetrating neural microelectrode arrays , 2010, Biomedical microdevices.

[39]  Patrick Ruther,et al.  Short and long term biocompatibility of NeuroProbes silicon probes , 2010, Journal of Neuroscience Methods.

[40]  Y. Chen,et al.  Design and fabrication of a polyimide-based microelectrode array: Application in neural recording and repeatable electrolytic lesion in rat brain , 2009, Journal of Neuroscience Methods.

[41]  Brian J. Kim,et al.  Micromachining of Parylene C for bioMEMS , 2016 .

[42]  G. Buzsáki Large-scale recording of neuronal ensembles , 2004, Nature Neuroscience.

[43]  M DE CARLO,et al.  [The spontaneous electrical activity of the human thyroid gland. II. Changes under the influence of sympathomimetic drugs]. , 1958, Archivio "E. Maragliano" di patologia e clinica.

[44]  T. Stieglitz,et al.  Polymers for neural implants , 2011 .

[45]  K. Wise,et al.  A Low-Profile Three-Dimensional Silicon/Parylene Stimulating Electrode Array for Neural Prosthesis Applications , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[46]  Dimiter Prodanov,et al.  Mechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design , 2016, Front. Neurosci..

[47]  Justin C. Sanchez,et al.  Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants , 2012, Journal of neural engineering.

[48]  Juliane Junker,et al.  Sterilisation Of Biomaterials And Medical Devices , 2016 .

[49]  Je Minkyu,et al.  Integration of low profile neural probe array with flexible polyimide cable , 2011, 2011 IEEE 13th Electronics Packaging Technology Conference.

[50]  Fan Wu,et al.  A flexible fish-bone-shaped neural probe strengthened by biodegradable silk coating for enhanced biocompatibility , 2011, 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference.

[51]  Winnie Jensen,et al.  Introduction to Neural Engineering for Motor Rehabilitation , 2013 .

[52]  Soowon Shin,et al.  Liquid crystal polymer (LCP)-based neural prosthetic devices , 2016 .

[53]  Paul Burt Local removal of glass insulation from metal microelectrodes by air-abrasion , 1966 .

[54]  D WILLIAMS,et al.  The spontaneous electrical activity of the human thalamus. , 1949, Brain : a journal of neurology.

[55]  Reid R. Harrison,et al.  The Design of Integrated Circuits to Observe Brain Activity , 2008, Proceedings of the IEEE.

[56]  R. Bellamkonda,et al.  Biomechanical analysis of silicon microelectrode-induced strain in the brain , 2005, Journal of neural engineering.

[57]  J. Kubie A driveable bundle of microwires for collecting single-unit data from freely-moving rats , 1984, Physiology & Behavior.

[58]  Jerald D. Kralik,et al.  Chronic, multisite, multielectrode recordings in macaque monkeys , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[59]  Henrik Jörntell,et al.  Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS , 2011, PloS one.

[60]  Paras R. Patel,et al.  Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces. , 2012, Nature materials.

[61]  T L Babb,et al.  Activity of human hippocampal formation and amygdala neurons during memory testing. , 1978, Electroencephalography and clinical neurophysiology.

[62]  Kensuke Kawai,et al.  Simultaneous Recording of Single-Neuron Activities and Broad-Area Intracranial Electroencephalography: Electrode Design and Implantation Procedure , 2013, Neurosurgery.

[63]  S. Takeuchi,et al.  Fabrication of Flexible Neural Probes With Built-In Microfluidic Channels by Thermal Bonding of Parylene , 2006, Journal of Microelectromechanical Systems.

[64]  G. E. Loeb,et al.  Toward the ultimate metal microelectrode , 1995, Journal of Neuroscience Methods.

[65]  Harry Grundfest,et al.  Stainless Steel Micro‐Needle Electrodes Made by Electrolytic Pointing , 1950 .

[66]  Steve M. Potter,et al.  Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black , 2010, Front. Neuroeng..

[67]  Sylvain Martel,et al.  Design and fabrication of a microelectrode array dedicated for cortical electrical stimulation , 2003, CCECE 2003 - Canadian Conference on Electrical and Computer Engineering. Toward a Caring and Humane Technology (Cat. No.03CH37436).

[68]  E. Adrian,et al.  The discharge of impulses in motor nerve fibres , 1929, The Journal of physiology.

[69]  Arati Sridharan,et al.  Long-term changes in the material properties of brain tissue at the implant–tissue interface , 2013, Journal of neural engineering.

[70]  Ellis Meng,et al.  Materials for microfabricated implantable devices: a review. , 2015, Lab on a chip.

[71]  Justin C. Williams,et al.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex , 2004, IEEE Transactions on Biomedical Engineering.

[72]  Kensall D. Wise,et al.  A dissolved wafer process using a porous silicon sacrificial layer and a lightly-doped bulk silicon etch-stop , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[73]  Erika L. Varner,et al.  Enhanced Intracranial Microdialysis by Reduction of Traumatic Penetration Injury at the Probe Track. , 2016, ACS chemical neuroscience.

[74]  C. H. Vanderwolf,et al.  Construction of wire leads and electrodes for use in slow wave recording in small animals , 1978, Brain Research Bulletin.

[75]  K. Mabuchi,et al.  A 3D flexible parylene probe array for multichannel neural recording , 2003, First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings..

[76]  Hong Gue Shin,et al.  Straightening of micro wires using the direct wire heating and pulling method , 2007 .

[77]  David C. Martin,et al.  Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film , 2006, Journal of neural engineering.

[78]  Emad N. Eskandar,et al.  Package architecture and component design for an implanted neural stimulator with closed loop control , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[79]  L. Carin,et al.  Relationship between intracortical electrode design and chronic recording function. , 2013, Biomaterials.

[80]  Ulrich G. Hofmann,et al.  A neural probe process enabling variable electrode configurations , 2004 .

[81]  Wei Mong Tsang,et al.  Microfabricated porous silicon backbone for stable neural interfaces , 2016 .

[82]  F. Hyder,et al.  Cerebral energetics and spiking frequency: The neurophysiological basis of fMRI , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[83]  M Salcman,et al.  Design, fabrication, and in vivo behavior of chronic recording intracortical microelectrodes. , 1973, IEEE transactions on bio-medical engineering.

[84]  Andrew S. Whitford,et al.  Cortical control of a prosthetic arm for self-feeding , 2008, Nature.

[85]  Mark Bachman,et al.  Microelectrode arrays fabricated using a novel hybrid microfabrication method , 2012, Biomedical microdevices.

[86]  Chien-Chung Fu,et al.  Different fabrication methods of out-of-plane polymer hollow needle arrays and their variations , 2007 .

[87]  Dirk Van Roost,et al.  Deep Brain Stimulation in Patients with Refractory Temporal Lobe Epilepsy , 2007, Epilepsia.

[88]  Justin C. Sanchez,et al.  Electrode impedance analysis of chronic tungsten microwire neural implants: understanding abiotic vs. biotic contributions , 2014, Front. Neuroeng..

[89]  M. Ward,et al.  Toward a comparison of microelectrodes for acute and chronic recordings , 2009, Brain Research.

[90]  C. Palmer A microwire technique for recording single neurons in unrestrained animals , 1978, Brain Research Bulletin.

[91]  P. Kennedy,et al.  Restoration of neural output from a paralyzed patient by a direct brain connection , 1998, Neuroreport.

[92]  Elan D. Louis,et al.  Estimating the Proportion of Essential Tremor and Parkinson's Disease Patients Undergoing Deep Brain Stimulation Surgery: Five‐Year Data From Columbia University Medical Center (2009–2014) , 2015, Movement disorders clinical practice.

[93]  J. D. Green,et al.  A Simple Microelectrode for recording from the Central Nervous System , 1958, Nature.

[94]  José Higino Correia,et al.  Fabrication and mechanical characterization of long and different penetrating length neural microelectrode arrays , 2015 .

[95]  Brian J. Kim,et al.  Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration. , 2013, Lab on a chip.

[96]  Toh-Ming Lu,et al.  Chemical Vapor Deposition Polymerization , 2004 .

[97]  Michael Chopp,et al.  Measurement of neuronal activity of individual neurons after stroke in the rat using a microwire electrode array , 2007, Journal of Neuroscience Methods.

[98]  A. Michael,et al.  Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies , 2014, ACS chemical neuroscience.

[99]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[100]  Jessica K. Nguyen,et al.  Mechanically-compliant intracortical implants reduce the neuroinflammatory response , 2014, Journal of neural engineering.

[101]  N. Dias,et al.  Invasive neural electrodes structure fabrication based on aluminum wafers , 2012 .

[102]  Maysam Ghovanloo,et al.  A wireless slanted optrode array with integrated micro leds for optogenetics , 2014, 2014 IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS).

[103]  John K. Chapin,et al.  Ceramic-based multisite electrode arrays for chronic single-neuron recording , 2004, IEEE Transactions on Biomedical Engineering.

[104]  P. Wolf Thermal Considerations for the Design of an Implanted Cortical Brain–Machine Interface (BMI) , 2008 .

[105]  István Ulbert,et al.  A novel multisite silicon probe for high quality laminar neural recordings , 2011 .

[106]  Hongda Chen,et al.  PEDOT/MWCNT composite film coated microelectrode arrays for neural interface improvement , 2013 .

[107]  M. Abidian,et al.  A Review of Organic and Inorganic Biomaterials for Neural Interfaces , 2014, Advanced materials.

[108]  M. Adamov,et al.  Electrical and structural properties of thin gold films obtained by vacuum evaporation and sputtering , 1974 .

[109]  K. Najafi,et al.  Scaling limitations of silicon multichannel recording probes , 1990, IEEE Transactions on Biomedical Engineering.

[110]  Ho-Yin Chan,et al.  A Novel Diamond Microprobe for Neuro-Chemical and -Electrical Recording in Neural Prosthesis , 2009, Journal of Microelectromechanical Systems.

[111]  K.D. Wise,et al.  Silicon Microelectrodes with Flexible Integrated Cables for Neural Implant Applications , 2007, 2007 3rd International IEEE/EMBS Conference on Neural Engineering.

[112]  U. Hofmann,et al.  Institute of Physics Publishing Journal of Micromechanics and Microengineering a 32-site Neural Recording Probe Fabricated by Drie of Soi Substrates , 2022 .

[113]  Zhuolin Xiang,et al.  A flexible three-dimensional electrode mesh: An enabling technology for wireless brain–computer interface prostheses , 2016, Microsystems & Nanoengineering.

[114]  E. Marg,et al.  Indwelling multiple micro-electrodes in the brain. , 1967, Electroencephalography and clinical neurophysiology.

[115]  Weileun Fang,et al.  Novel glass microprobe arrays for neural recording. , 2009, Biosensors & bioelectronics.

[116]  Weileun Fang,et al.  A pseudo 3D glass microprobe array: glass microprobe with embedded silicon for alignment and electrical interconnection during assembly , 2010 .

[117]  Christof Koch,et al.  Worldwide initiatives to advance brain research , 2016, Nature Neuroscience.

[118]  W. Grill,et al.  Deep brain stimulation creates an informational lesion of the stimulated nucleus , 2004, Neuroreport.

[119]  Xiaorong Gao,et al.  Silicon-based wire electrode array for neural interfaces , 2014 .

[120]  G. Rizzolatti,et al.  Seven Years of Recording from Monkey Cortex with a Chronically Implanted Multiple Microelectrode , 2010, Front. Neuroeng..

[121]  F. Solzbacher,et al.  Fabrication of 3-dimensional silicon microelectrode arrays using micro electro discharge machining for neural applications , 2009, TRANSDUCERS 2009 - 2009 International Solid-State Sensors, Actuators and Microsystems Conference.

[122]  Rajmohan Bhandari,et al.  A novel masking method for high aspect ratio penetrating microelectrode arrays , 2009 .

[123]  Chunsheng Yang,et al.  Implantable electrode array with platinum black coating for brain stimulation in fish , 2015 .

[124]  Justin C. Williams,et al.  Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.

[125]  G. Whitesides,et al.  Soft lithography for micro- and nanoscale patterning , 2010, Nature Protocols.

[126]  Chris Van Hoof,et al.  Fabrication technique of a compressible biocompatible interconnect using a thin film transfer process , 2011 .

[127]  Shang-Lin Wu,et al.  An ultra-high-density 256-channel/25mm2 neural sensing microsystem using TSV-embedded neural probes , 2016, 2016 IEEE International Symposium on Circuits and Systems (ISCAS).

[128]  M. Eddleston,et al.  Molecular profile of reactive astrocytes—Implications for their role in neurologic disease , 1993, Neuroscience.

[129]  Gabriel A. Silva,et al.  Neuroscience nanotechnology: progress, opportunities and challenges , 2006, Nature Reviews Neuroscience.

[130]  Michael L. Roukes,et al.  Iop Publishing Journal of Micromechanics and Microengineering Dual-side and Three-dimensional Microelectrode Arrays Fabricated from Ultra-thin Silicon Substrates , 2022 .

[131]  F Solzbacher,et al.  A Wafer-Scale Etching Technique for High Aspect Ratio Implantable MEMS Structures. , 2010, Sensors and actuators. A, Physical.

[132]  Yusuke Nakamura,et al.  Effect of oxygen plasma etching on adhesion between polyimide films and metal , 1996 .

[133]  Shashi K. Murthy,et al.  Bridging the Divide between Neuroprosthetic Design, Tissue Engineering and Neurobiology , 2009, Front. Neuroeng..

[134]  F. Solzbacher,et al.  Wafer-scale processed, low impedance, neural arrays with varying length microelectrodes , 2009, TRANSDUCERS 2009 - 2009 International Solid-State Sensors, Actuators and Microsystems Conference.

[135]  Toh-Ming Lu,et al.  Chemical Vapor Deposition Polymerization: The Growth and Properties of Parylene Thin Films , 2003 .

[136]  G. Deuschl,et al.  A randomized trial of deep-brain stimulation for Parkinson's disease. , 2006, The New England journal of medicine.

[137]  Shang-Lin Wu,et al.  A double-sided, single-chip integration scheme using through-silicon-via for neural sensing applications , 2015, Biomedical microdevices.

[138]  K. Moxon,et al.  Ceramic-based multisite microelectrodes for electrochemical recordings. , 2000, Analytical chemistry.

[139]  Nancy Kopell,et al.  Close-Packed Silicon Microelectrodes for Scalable Spatially Oversampled Neural Recording , 2015, IEEE Transactions on Biomedical Engineering.

[140]  D. Kipke,et al.  Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex. , 1999, Brain research. Brain research protocols.

[141]  M L Wolbarsht,et al.  Glass Insulated Platinum Microelectrode , 1960, Science.

[142]  Chen-Tung Yen,et al.  A simple method for fabricating horizontal and vertical microwire arrays , 2003, Journal of Neuroscience Methods.

[143]  S. Pang,et al.  Electrode modifications to lower electrode impedance and improve neural signal recording sensitivity , 2015, Journal of neural engineering.

[144]  Florian Solzbacher,et al.  Encapsulation of an Integrated Neural Interface Device With Parylene C , 2009, IEEE Transactions on Biomedical Engineering.

[145]  Steven L. Campbell,et al.  Definition of the Geometric Area of a Microelectrode Tip by Plasma Etching of Parylene , 1986, IEEE Transactions on Biomedical Engineering.

[146]  P. Renaud,et al.  Demonstration of cortical recording using novel flexible polymer neural probes , 2008 .

[147]  J. Anthony Movshon,et al.  Comparison of Recordings from Microelectrode Arrays and Single Electrodes in the Visual Cortex , 2007, The Journal of Neuroscience.

[148]  Christopher L. Frewin,et al.  SiC for Biomedical Applications , 2016 .

[149]  Amir M. Sodagar,et al.  Microelectrodes, Microelectronics, and Implantable Neural Microsystems , 2008, Proceedings of the IEEE.

[150]  Christoph Weder,et al.  Progress towards biocompatible intracortical microelectrodes for neural interfacing applications , 2015, Journal of neural engineering.

[151]  Brian J. Kim,et al.  3D Parylene sheath neural probe for chronic recordings , 2013, Journal of neural engineering.

[152]  P. Tresco,et al.  Response of brain tissue to chronically implanted neural electrodes , 2005, Journal of Neuroscience Methods.

[153]  Matthew J Nelson,et al.  Do electrode properties create a problem in interpreting local field potential recordings? , 2010, Journal of neurophysiology.

[154]  F R ROBINSON,et al.  Histopathological studies of tissue reactions to various metals implanted in cat brains. , 1961, ASD technical report. United States. Air Force. Systems Command. Aeronautical Systems Division.

[155]  J. Muthuswamy,et al.  Thin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortex , 2007, Journal of neural engineering.

[156]  Florian Solzbacher,et al.  Fabrication of compliant high aspect ratio silicon microelectrode arrays using micro-wire electrical discharge machining , 2009 .

[157]  Chenyang Xue,et al.  Fabrication of polyimide sacrificial layers with inclined sidewalls based on reactive ion etching , 2014 .

[158]  K. L. Mittal,et al.  Polyimides: Fundamentals and Applications , 1996 .

[159]  A. Destée,et al.  Bilateral deep-brain stimulation of the globus pallidus in primary generalized dystonia. , 2005, The New England journal of medicine.

[160]  Rajmohan Bhandari,et al.  Neural electrode degradation from continuous electrical stimulation: Comparison of sputtered and activated iridium oxide , 2010, Journal of Neuroscience Methods.

[161]  Dieter Jaeger,et al.  A multiwire microelectrode for single unit recording in deep brain structures , 1990, Journal of Neuroscience Methods.

[162]  Sung June Kim,et al.  A micromachined silicon depth probe for multichannel neural recording , 2000, IEEE Transactions on Biomedical Engineering.

[163]  Florian Solzbacher,et al.  Hybrid laser and reactive ion etching of Parylene-C for deinsulation of a Utah electrode array , 2012 .

[164]  D. Tyler,et al.  Stimuli-Responsive Polymer Nanocomposites Inspired by the Sea Cucumber Dermis , 2008, Science.

[165]  Miguel A. L. Nicolelis,et al.  State-of-the-Art Microwire Array Design for Chronic Neural Recordings in Behaving Animals , 2008 .

[166]  Michael D Joseph,et al.  Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes , 2011, Journal of neural engineering.

[167]  G J Suaning,et al.  Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil , 2005, Journal of neural engineering.

[168]  Daniel R. Merrill Materials considerations of implantable neuroengineering devices for clinical use , 2014 .

[169]  D. Szarowski,et al.  Brain responses to micro-machined silicon devices , 2003, Brain Research.

[170]  P Tathireddy,et al.  File Name: Quarterly Report Uofu Quarter 8 V4 Quarterly Report Chronic Microelectrode Recording Array , .

[171]  R A Normann,et al.  A 100 electrode intracortical array: structural variability. , 1990, Biomedical sciences instrumentation.

[172]  Ellis Meng,et al.  Formation of three-dimensional Parylene C structures via thermoforming , 2014 .

[173]  José Higino Correia,et al.  Microshaping of Aluminum-based Neural Microelectrode Arrays Using Chemical Wet-etching , 2014 .

[174]  Martin J. Bak,et al.  THUMBTACK MICROELECTRODE AND METHOD OF MAKING SAME FIELD OF THE INVENTION , 2017 .

[175]  J.P. Donoghue,et al.  Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[176]  Shang-Lin Wu,et al.  2.5D Heterogeneously Integrated Microsystem for High-Density Neural Sensing Applications , 2014, IEEE Transactions on Biomedical Circuits and Systems.

[177]  Peter Vettiger,et al.  High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS , 1998 .

[178]  Jeffrey A. Loeb,et al.  Microfabrication of 3D neural probes with combined electrical and chemical interfaces , 2010 .

[179]  Luke P. Lee,et al.  A new neural probe using SOI wafers with topological interlocking mechanisms , 2000, 1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.00EX451).

[180]  W. Miles Clift,et al.  Removal of SU-8 photoresist for thick film applications , 2002 .

[181]  K. Wise,et al.  Silicon ribbon cables for chronically implantable microelectrode arrays , 1994, IEEE Transactions on Biomedical Engineering.

[182]  P. T. Thorbergsson,et al.  An array of highly flexible electrodes with a tailored configuration locked by gelatin during implantation—initial evaluation in cortex cerebri of awake rats , 2015, Front. Neurosci..

[183]  Mikhail A. Lebedev,et al.  Chronic, Wireless Recordings of Large Scale Brain Activity in Freely Moving Rhesus Monkeys , 2014, Nature Methods.

[184]  Rosa Villa,et al.  Study of functional viability of SU-8-based microneedles for neural applications , 2009 .

[185]  W. R. Levick,et al.  Another tungsten microelectrode , 1972, Medical and biological engineering.

[186]  István Ulbert,et al.  Multiple microelectrode-recording system for human intracortical applications , 2001, Journal of Neuroscience Methods.

[187]  M. M. H. Shandhi,et al.  A novel method of fabricating high channel density neural array for large neuronal mapping , 2015, 2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS).

[188]  K. E. Jones,et al.  A glass/silicon composite intracortical electrode array , 2006, Annals of Biomedical Engineering.

[189]  Richard Ulrich,et al.  Thermosonic Gold Wirebonding to Electrolessly-Metallized Copper Bondpads over Benzocyclobutene , 1999 .

[190]  H. Jasper,et al.  ELECTRICAL ACTIVITY OF THE CEREBRAL CORTEX IN THE UNANESTHETIZED CAT , 1937 .

[191]  Stuart F Cogan,et al.  Plasma-enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating. , 2003, Journal of biomedical materials research. Part A.

[192]  Mark G. Allen,et al.  Highly-compliant, microcable neuroelectrodes fabricated from thin-film gold and PDMS , 2011, Biomedical microdevices.

[193]  D Giulian,et al.  The impact of microglia-derived cytokines upon gliosis in the CNS. , 1994, Developmental neuroscience.

[194]  George L. Gerstein,et al.  A rapid method for production of sharp tips on preinsulated microwires , 1986, Journal of Neuroscience Methods.

[195]  G. Kotzar,et al.  Evaluation of MEMS materials of construction for implantable medical devices. , 2002, Biomaterials.

[196]  William Paul,et al.  Note: electrochemical etching of sharp iridium tips. , 2011, The Review of scientific instruments.

[197]  R. Bellamkonda,et al.  A Novel Dexamethasone-releasing, Anti-inflammatory Coating for Neural Implants , 2005, Conference Proceedings. 2nd International IEEE EMBS Conference on Neural Engineering, 2005..

[198]  Stephen T. Newman,et al.  State of the art electrical discharge machining (EDM) , 2003 .

[199]  Jerald D. Kralik,et al.  Real-time prediction of hand trajectory by ensembles of cortical neurons in primates , 2000, Nature.

[200]  J. Ohta,et al.  The development of a multichannel electrode array for retinal prostheses , 2006, Journal of Artificial Organs.

[201]  David F. Williams On the mechanisms of biocompatibility. , 2008, Biomaterials.

[202]  Lei Yao,et al.  A low-profile three-dimensional neural probe array using a silicon lead transfer structure , 2013 .

[203]  K. Djupsund,et al.  Flexible polyimide microelectrode array for in vivo recordings and current source density analysis. , 2007, Biosensors & bioelectronics.

[204]  Patrick Ruther,et al.  Mechanically Adaptive Silicon-based Neural Probes for Chronic High-resolution Neural Recording , 2015 .

[205]  K. Seshan,et al.  Handbook of Thin Film Deposition Processes and Techniques: Principles, Methods, Equipment and Applications , 2001 .

[206]  G B Stanley,et al.  Reconstruction of Natural Scenes from Ensemble Responses in the Lateral Geniculate Nucleus , 1999, The Journal of Neuroscience.

[207]  E. Bassous Fabrication of novel three-dimensional microstructures by the anisotropic etching of , 1978, IEEE Transactions on Electron Devices.

[208]  Thomas Lippert,et al.  UV Laser Ablation of Polymers: From Structuring to Thin Film Deposition , 2010 .

[209]  W. Kuziel,et al.  Chemokine Expression by Glial Cells Directs Leukocytes to Sites of Axonal Injury in the CNS , 2003, The Journal of Neuroscience.

[210]  K. Horch,et al.  A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array , 1991, IEEE Transactions on Biomedical Engineering.

[211]  Henrik Jörntell,et al.  Nanowire-Based Electrode for Acute In Vivo Neural Recordings in the Brain , 2013, PloS one.

[212]  Shang-Lin Wu,et al.  Integrated microprobe array and CMOS MEMS by TSV technology for bio-signal recording application , 2014, 2014 IEEE 64th Electronic Components and Technology Conference (ECTC).

[213]  J. Delgado,et al.  Permanent Implantation of Multilead Electrodes in the Brain * , 1952, The Yale journal of biology and medicine.

[214]  Mohamad Sawan,et al.  High-Density Implantable Microelectrode Arrays for Brain-Machine Interface Applications , 2014 .

[215]  Edgard Morya,et al.  Comprehensive Analysis of Tissue Preservation and Recording Quality from Chronic Multielectrode Implants , 2011, PloS one.

[216]  Stuart N. Baker,et al.  Newcastle University Eprints Date Deposited: 23 the Sinusoidal Probe: a New Approach to Improve Electrode Longevity , 2022 .

[217]  S S Stensaas,et al.  The reaction of the cerebral cortex to chronically implanted plastic needles. , 1976, Acta neuropathologica.

[218]  Ellis Meng,et al.  Review of polymer MEMS micromachining , 2015 .

[219]  Walter Lang,et al.  Design and fabrication of novel multi-channel floating neural probes for intracortical chronic recording , 2016 .

[220]  Shih-Rung Yeh,et al.  Micro-multi-probe electrode array to measure neural signals. , 2009, Biosensors & bioelectronics.

[221]  Gwo-Bin Lee,et al.  A new fabrication process for ultra-thick microfluidic microstructures utilizing SU-8 photoresist , 2002 .

[222]  G. Ojemann,et al.  Neuronal activity in human lateral temporal cortex during serial retrieval from short-term memory , 1994, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[223]  Jens Schouenborg,et al.  Influence of Probe Flexibility and Gelatin Embedding on Neuronal Density and Glial Responses to Brain Implants , 2015, PloS one.

[224]  David C. Martin,et al.  Electrochemical deposition and characterization of poly(3,4-ethylenedioxythiophene) on neural microelectrode arrays , 2003 .

[225]  Jiping He,et al.  Biocompatible benzocyclobutene-based intracortical neural implant with surface modification , 2005 .

[226]  J. A. W. M. Weijnen,et al.  A slim needle-shaped multiwire microelectrode for intracerebral recording , 1991, Journal of Neuroscience Methods.

[227]  F. Solzbacher,et al.  Integrated wireless neural interface based on the Utah electrode array , 2009, Biomedical microdevices.

[228]  K. Mabuchi,et al.  3D flexible multichannel neural probe array , 2004 .

[229]  D. Edell,et al.  Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex , 1992, IEEE Transactions on Biomedical Engineering.

[230]  Yoon-Kyu Song,et al.  A microelectrode/microelectronic hybrid device for brain implantable neuroprosthesis applications , 2004, IEEE Transactions on Biomedical Engineering.

[231]  Garrett B Stanley,et al.  The impact of chronic blood-brain barrier breach on intracortical electrode function. , 2013, Biomaterials.

[232]  C. Lieber,et al.  Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes. , 2015, Nature materials.

[233]  Robert C. Cammarata,et al.  SURFACE AND INTERFACE STRESS EFFECTS IN THIN FILMS , 1994 .

[234]  M. Nicolelis,et al.  Principal component analysis of neuronal ensemble activity reveals multidimensional somatosensory representations , 1999, Journal of Neuroscience Methods.

[235]  Justin C. Sanchez,et al.  Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing , 2012, Journal of neural engineering.

[236]  P. Tresco,et al.  The challenge of integrating devices into the central nervous system. , 2011, Critical reviews in biomedical engineering.

[237]  William C. Tang,et al.  SU-8/silicon hybrid three dimensional intraneural electrode array , 2013, 2013 6th International IEEE/EMBS Conference on Neural Engineering (NER).

[238]  A. Aertsen,et al.  Spike synchronization and rate modulation differentially involved in motor cortical function. , 1997, Science.

[239]  Joaquin M. Fuster,et al.  The elgiloy microelectrode: Fabrication techniques and characteristics , 1985, Journal of Neuroscience Methods.

[240]  A. Verloop,et al.  A simple method for the construction of electrode arrays , 1984, Journal of Neuroscience Methods.

[241]  C. Greiner,et al.  SU-8: a photoresist for high-aspect-ratio and 3D submicron lithography , 2007 .

[242]  Guangqiang Jiang,et al.  Technology Advances and Challenges in Hermetic Packaging for Implantable Medical Devices , 2009 .

[243]  Dong-il Dan Cho,et al.  Roughened polysilicon for low impedance microelectrodes in neural probes , 2003 .

[244]  K. Wise,et al.  An integrated-circuit approach to extracellular microelectrodes. , 1970, IEEE transactions on bio-medical engineering.

[245]  R. Andersen,et al.  A New Multi-Site Probe Array with Monolithically Integrated Parylene Flexible Cable for Neural Prostheses , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[246]  Ing-Shouh Hwang,et al.  Method of electrochemical etching of tungsten tips with controllable profiles. , 2012, The Review of scientific instruments.

[247]  M. Madou Fundamentals of microfabrication : the science of miniaturization , 2002 .