Diagnosing and Mapping Pulmonary Emphysema on X-Ray Projection Images: Incremental Value of Grating-Based X-Ray Dark-Field Imaging

Purpose To assess whether grating-based X-ray dark-field imaging can increase the sensitivity of X-ray projection images in the diagnosis of pulmonary emphysema and allow for a more accurate assessment of emphysema distribution. Materials and Methods Lungs from three mice with pulmonary emphysema and three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Median signal intensities of transmission (T), dark-field (V) and a combined parameter (normalized scatter) were compared between emphysema and control group. To determine the diagnostic value of each parameter in differentiating between healthy and emphysematous lung tissue, a receiver-operating-characteristic (ROC) curve analysis was performed both on a per-pixel and a per-individual basis. Parametric maps of emphysema distribution were generated using transmission, dark-field and normalized scatter signal and correlated with histopathology. Results Transmission values relative to water were higher for emphysematous lungs than for control lungs (1.11 vs. 1.06, p<0.001). There was no difference in median dark-field signal intensities between both groups (0.66 vs. 0.66). Median normalized scatter was significantly lower in the emphysematous lungs compared to controls (4.9 vs. 10.8, p<0.001), and was the best parameter for differentiation of healthy vs. emphysematous lung tissue. In a per-pixel analysis, the area under the ROC curve (AUC) for the normalized scatter value was significantly higher than for transmission (0.86 vs. 0.78, p<0.001) and dark-field value (0.86 vs. 0.52, p<0.001) alone. Normalized scatter showed very high sensitivity for a wide range of specificity values (94% sensitivity at 75% specificity). Using the normalized scatter signal to display the regional distribution of emphysema provides color-coded parametric maps, which show the best correlation with histopathology. Conclusion In a murine model, the complementary information provided by X-ray transmission and dark-field images adds incremental diagnostic value in detecting pulmonary emphysema and visualizing its regional distribution as compared to conventional X-ray projections.

[1]  W M Thurlbeck,et al.  Radiographic appearance of the chest in emphysema. , 1978, AJR. American journal of roentgenology.

[2]  E. DeLong,et al.  Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. , 1988, Biometrics.

[3]  N L Müller,et al.  Chronic obstructive pulmonary disease • 4: Imaging the lungs in patients with chronic obstructive pulmonary disease , 2002, Thorax.

[4]  D. Postma,et al.  Chronic obstructive pulmonary disease. , 2002, Clinical evidence.

[5]  Jan Stolk,et al.  Optimization and Standardization of Lung Densitometry in the Assessment of Pulmonary Emphysema , 2004, Investigative radiology.

[6]  Martin J Yaffe,et al.  Reference values for diagnostic radiology: application and impact. , 2005, Radiology.

[7]  Alan D. Lopez,et al.  The Burden of Disease and Mortality by Condition: Data, Methods, and Results for 2001 -- Global Burden of Disease and Risk Factors , 2006 .

[8]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[9]  Alan D. Lopez,et al.  Global burden of disease and risk factors , 2006 .

[10]  B C Stoel,et al.  Validation of computed tomographic lung densitometry for monitoring emphysema in α1-antitrypsin deficiency , 2006, Thorax.

[11]  K. Rabe,et al.  Value of chest radiography in phenotyping chronic obstructive pulmonary disease , 2008, European Respiratory Journal.

[12]  Johan H C Reiber,et al.  Volume correction in computed tomography densitometry for follow-up studies on pulmonary emphysema. , 2008, Proceedings of the American Thoracic Society.

[13]  G. Washko,et al.  Radiographic evaluation of the potential lung volume reduction surgery candidate. , 2008, Proceedings of the American Thoracic Society.

[14]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[15]  Franz Pfeiffer,et al.  Soft-tissue phase-contrast tomography with an x-ray tube source , 2009, Physics in medicine and biology.

[16]  A. Dirksen,et al.  Exploring the optimum approach to the use of CT densitometry in a randomised placebo-controlled study of augmentation therapy in alpha 1-antitrypsin deficiency , 2009, Respiratory research.

[17]  D. Price,et al.  Screening for and early detection of chronic obstructive pulmonary disease , 2009, The Lancet.

[18]  Jonathan G Goldin,et al.  Imaging the lungs in patients with pulmonary emphysema. , 2009, Journal of thoracic imaging.

[19]  Franz Pfeiffer,et al.  Quantitative phase-contrast tomography of a liquid phantom using a conventional x-ray tube source. , 2009, Optics express.

[20]  Stefano Diciotti,et al.  Whole-lung densitometry versus visual assessment of emphysema , 2009, European Radiology.

[21]  A. Dirksen,et al.  Exploring the role of CT densitometry: a randomised study of augmentation therapy in α1-antitrypsin deficiency , 2009, European Respiratory Journal.

[22]  Franz Pfeiffer,et al.  Toward Clinical X-ray Phase-Contrast CT: Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen , 2010, Investigative radiology.

[23]  G. Washko Diagnostic imaging in COPD. , 2010, Seminars in respiratory and critical care medicine.

[24]  G. Criner,et al.  Lung volume reduction surgery and lung volume reduction in advanced emphysema: who and why? , 2010, Seminars in respiratory and critical care medicine.

[25]  M. Kasper,et al.  Palifermin induces alveolar maintenance programs in emphysematous mice. , 2010, American journal of respiratory and critical care medicine.

[26]  Franz Pfeiffer,et al.  Quantitative x-ray dark-field computed tomography , 2010, Physics in medicine and biology.

[27]  G. McLennan,et al.  A randomized study of endobronchial valves for advanced emphysema. , 2010, The New England journal of medicine.

[28]  M. McNitt-Gray,et al.  Reproducibility of volume and densitometric measures of emphysema on repeat computed tomography with an interval of 1 week , 2012, European Radiology.

[29]  Franz Pfeiffer,et al.  Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light source , 2012, Proceedings of the National Academy of Sciences.

[30]  Torben H. Jensen,et al.  Experimental validation of image contrast correlation between ultra-small-angle X-ray scattering and grating-based dark-field imaging using a laser-driven compact X-ray source , 2012 .

[31]  P. C. Diemoz,et al.  Theoretical comparison of three X-ray phase-contrast imaging techniques: propagation-based imaging, analyzer-based imaging and grating interferometry. , 2012, Optics express.