Lightning-Induced Voltages on Overhead Lines—Application of the Extended Rusck Model

Lightning-induced overvoltages have a considerable impact on the power quality of overhead distribution and telecommunications systems, and various models have been developed for the computation of the electromagnetic transients caused by indirect strokes. The most adequate has been shown to be the one proposed by Agrawal ; the Rusck model can be visualized as a particular case, as both models are equivalent when the lightning channel is perpendicular to the ground plane. In this paper, an extension of the Rusck model that enables the calculation of lightning-induced transients considering flashes to nearby elevated structures and realistic line configurations is tested against data obtained from both natural lightning and scale model experiments. The latter, performed under controlled conditions, can be used also to verify the validity of other coupling models and relevant codes. The so-called Extended Rusck Model, which is shown to be sufficiently accurate, is applied to the analysis of lightning-induced voltages on lines with a shield wire and/or surge arresters. The investigation conducted indicates that the ratio between the peak values of the voltages induced by typical first and subsequent strokes can be either greater or smaller than the unity, depending on the line configuration.

[1]  T. A. Short,et al.  Induced voltage measurements on an experimental distribution line during nearby rocket triggered lightning flashes , 1996 .

[2]  M. Darveniza,et al.  A Practical Extension of Rusck's Formula for Maximum Lightning-Induced Voltages That Accounts for Ground Resistivity , 2007, IEEE Transactions on Power Delivery.

[3]  Kunihiko Miyake,et al.  Advanced Observations of Lightning Induced Voltage on Power Distribution Lines (II) , 1986, IEEE Power Engineering Review.

[4]  Y. Baba,et al.  Voltages induced on an overhead wire by lightning strikes to a nearby tall grounded object , 2006, IEEE Transactions on Electromagnetic Compatibility.

[5]  V. Cooray,et al.  Shapes and amplitudes of the initial peaks of lightning-induced voltage in power lines over finitely conducting earth: Theory and comparison with experiment , 1986 .

[6]  M. Uman,et al.  Magnetic field of lightning return stroke , 1969 .

[7]  M. Ianoz,et al.  Transient analysis of multiconductor lines above a lossy ground , 1999 .

[8]  P. Chowdhuri,et al.  Analysis of lightning-induced voltages on overhead lines , 1989 .

[9]  A. C. Liew,et al.  Extension of the Chowdhuri-Gross Model for Lightning Induced Voltage on Overhead Lines , 1986, IEEE Power Engineering Review.

[10]  Carlo Alberto Nucci Lightning - Induced voltages on distribution systems: influence of ground resistivity and system topology , 2007 .

[11]  Masaru Ishii,et al.  Experimental study of lightning-induced voltage on an overhead wire over lossy ground , 1999 .

[12]  Alexandre Piantini,et al.  Influence of the upward leader on lightning induced voltages , 1996 .

[13]  Hans Kristian Hoidalen,et al.  Analytical formulation of lightning-induced voltages on multiconductor overhead lines above lossy ground , 2003 .

[14]  M. Ianoz,et al.  Comparison of two coupling models for lightning-induced overvoltage calculations , 1995 .

[15]  Martin A. Uman,et al.  Measurements of the voltage induced on an overhead power line 20 m from triggered lightning , 1994 .

[16]  Kunihiko Miyake,et al.  Advanced Observations of Lightning Induced Voltage on Power Distribution Lines , 1986, IEEE Transactions on Power Delivery.

[17]  M. Ianoz,et al.  Influence of a lossy ground on lightning-induced voltages on overhead lines , 1996 .

[18]  M. Paolone,et al.  An Improved Procedure for the Assessment of Overhead Line Indirect Lightning Performance and Its Comparison with the IEEE Std. 1410 Method , 2007, IEEE Transactions on Power Delivery.

[19]  Shigeru Yokoyama,et al.  Lightning protection of overhead power distribution lines , 2006 .

[20]  Alexandre Piantini,et al.  Induced voltages on distribution lines due to lightning discharges on nearby metallic structures , 1998 .

[21]  Vernon Cooray,et al.  Calculating lightning-induced overvoltages in power lines. A comparison of two coupling models , 1994 .

[22]  Li-Hua Shi,et al.  Analysis of Lightning-Induced Voltages on Overhead Lines Using a 2-D FDTD Method and Agrawal Coupling Model , 2008, IEEE Transactions on Electromagnetic Compatibility.

[23]  S. Rusck,et al.  Induced-lightning overvoltages on power transmission lines with special reference to the overvoltage protection of low voltage networks , 1958 .

[24]  M. Ianoz,et al.  Lightning-induced voltages on overhead lines , 1993 .

[25]  Ashok K. Agrawal,et al.  Transient Response of Multiconductor Transmission Lines Excited by a Nonuniform Electromagnetic Field , 1980 .

[26]  Masaru Ishii,et al.  Voltage induced on a test distribution line by negative winter lightning strokes to a tall structure , 2003 .

[27]  Farhad Rachidi,et al.  Lightning-induced voltages on complex distribution systems: models, advanced software tools and experimental validation , 2004 .

[28]  A. Eriksson,et al.  Lightning-Induced Overvoltages on Overhead Distribution Lines , 1982 .

[29]  Masaru Ishii,et al.  Lightning-induced voltage on an overhead wire dependent on ground conductivity , 1994 .

[30]  S. Yokoyama Calculation of Lightning-Induced Voltages on Overhead Multiconductor Systems , 1984, IEEE Power Engineering Review.

[31]  A. Piantini,et al.  A Scale Model for the Study of the LEMP Response of Complex Power Distribution Networks , 2007, IEEE Transactions on Power Delivery.

[32]  Kunihiko Miyake,et al.  Simultaneous Measurement of Lightning Induced Voltages with Associated Stroke Currents , 1983, IEEE Transactions on Power Apparatus and Systems.

[33]  Masaru Ishii,et al.  Theoretical Comparison of Agrawal's and Rusck's Field-to-Line Coupling Models for Calculation of Lightning-Induced Voltage on An Overhead Wire , 1997 .

[34]  M. Ianoz,et al.  Lightning-induced voltages on an overhead line above a lossy ground: a sensitivity analysis , 1996 .

[35]  Mat Darveniza,et al.  Lightning Induced Voltages on Power Lines: Experiment , 1984, IEEE Transactions on Power Apparatus and Systems.

[36]  Alexandre Piantini,et al.  The extended rusck model for calculating lightning induced voltages on overhead lines , 2003 .

[37]  A. Piantini,et al.  An improved model for lightning induced voltages calculations , 2004, 2004 IEEE/PES Transmision and Distribution Conference and Exposition: Latin America (IEEE Cat. No. 04EX956).

[38]  P. Chowdhuri,et al.  Estimation of Flashover Rates of Overhead Power Distribution Lines by Lightning Strokes to Nearby Ground , 1989, IEEE Power Engineering Review.