Utility of the optical quality analysis system for decision-making in cataract surgery

BackgroundA cataract is a common cause of vision impairment that requires surgery in older subjects. The Optical Quality Analysis System (OQAS, Visiometrics SL, Terrassa, Spain) assesses the optical quality of the eye in cataract patients. This study shows the role of the optical quality evaluation system for decision-making in cataract surgery. We investigated the clinical utility of the OQAS for decision-making in cataract surgery.MethodsSixty-seven eyes from 67 patients undergoing cataract surgery and 109 eyes from 109 control subjects were compared. The best corrected visual acuity (BCVA) was measured. The objective scatter index (OSI), modulation transfer function (MTF), Strehl ratio, predicted visual acuity (PVA) 100%, PVA 20%, and PVA 10% were measured using the OQAS. The sensitivity and specificity of the different parameters were analyzed using the receiver operating characteristic (ROC) curve. The main parameters measured were sensitivity and specificity.ResultsThe BCVA, OSI, PVA 100%, PVA 20%, and PVA 10% were higher in the cataract group compared to those in the control group, while the MTF and Strehl ratios were lower (p <  0.001 for all). ROC analysis showed that the OSI had the largest area under the curve and that the sensitivity and specificity of the OSI were 83.9 and 84.6%, respectively, at the optimal cut-off point of 2.35.ConclusionThe MTF, OSI, Strehl ratio, PVA 100%, PVA 20% and PVA 10% may be useful parameters for preoperative decision-making in cataract surgery. The OSI appears to be the most effective parameter for this purpose.

[1]  E. Espana,et al.  Modulation transfer function and optical quality after bilateral implantation of a +3.00 D versus a +4.00 D multifocal intraocular lens , 2012, Journal of cataract and refractive surgery.

[2]  The value of routine preoperative medical testing before cataract surgery , 2000 .

[3]  So-Hyang Chung,et al.  Objective assessment of nuclear cataract: Comparison of double‐pass and Scheimpflug systems , 2014, Journal of cataract and refractive surgery.

[4]  Illés Kovács,et al.  OCULAR WAVEFRONT ABERRATIONS AND OPTICAL QUALITY IN DIABETIC MACULAR EDEMA , 2016, Retina.

[5]  A Hofman,et al.  Age-specific prevalence and causes of blindness and visual impairment in an older population: the Rotterdam Study. , 1998, Archives of ophthalmology.

[6]  F. Bao,et al.  Correlation among lens opacities classification system III grading, visual function index-14, pentacam nucleus staging, and objective scatter index for cataract assessment. , 2015, American journal of ophthalmology.

[7]  Kazunori Miyata,et al.  Age-related changes in corneal and ocular higher-order wavefront aberrations. , 2004, American journal of ophthalmology.

[8]  U. Stenevi,et al.  The changing pattern of cataract surgery indications: a 5-year study of 2 cataract surgery databases. , 2015, Ophthalmology.

[9]  R. Michael,et al.  Morphology of age-related cuneiform cortical cataracts: The case for mechanical stress , 2008, Vision Research.

[10]  P. Piers,et al.  Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses. , 2004, Journal of refractive surgery.

[11]  Jaume Pujol,et al.  Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument. , 2006, Investigative ophthalmology & visual science.

[12]  Jaume Pujol,et al.  An Objective Scatter Index Based on Double-Pass Retinal Images of a Point Source to Classify Cataracts , 2011, PloS one.

[13]  K. Hajian‐Tilaki,et al.  Receiver Operating Characteristic (ROC) Curve Analysis for Medical Diagnostic Test Evaluation. , 2013, Caspian journal of internal medicine.

[14]  Sunni R. Patel,et al.  Objective Scatter Index: Working Toward a New Quantification of Cataract? , 2016, Journal of refractive surgery.

[15]  S. Fraser,et al.  Cataract surgery and quality of life implications , 2007, Clinical interventions in aging.

[16]  J. Swets ROC analysis applied to the evaluation of medical imaging techniques. , 1979, Investigative radiology.

[17]  G. Vrensen,et al.  The Ageing Lens , 2000, Ophthalmologica.

[18]  W. Charman,et al.  Postblink changes in total and corneal ocular aberrations. , 2004, Ophthalmology.

[19]  J. Katz,et al.  The value of routine preoperative medical testing before cataract surgery. Study of Medical Testing for Cataract Surgery. , 2000, The New England journal of medicine.

[20]  Jaume Pujol,et al.  Optical Quality Analysis System; Instrument for objective clinical evaluation of ocular optical quality. , 2004, Journal of cataract and refractive surgery.

[21]  M. C. Leske,et al.  The Lens Opacities Classification System III , 1993 .

[22]  C. McAlinden,et al.  Objective assessment of crystalline lens opacity level by measuring ocular light scattering with a double-pass system. , 2013, American journal of ophthalmology.

[23]  K. Shimizu,et al.  Effect of Aging on Optical Quality and Intraocular Scattering Using the Double-Pass Instrument , 2012, Current eye research.

[24]  Hiroshi Uozato,et al.  Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitro , 2005, Journal of cataract and refractive surgery.

[25]  Franz König,et al.  Reading performance depending on the type of cataract and its predictability on the visual outcome , 2004, Journal of cataract and refractive surgery.

[26]  K. Shimizu,et al.  Clinical evaluation of optical quality and intraocular scattering after posterior chamber phakic intraocular lens implantation. , 2012, Investigative ophthalmology & visual science.

[27]  Xingtao Zhou,et al.  Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children , 2015, PloS one.

[28]  Y. Chen,et al.  Correlation of lens density measured using the Pentacam Scheimpflug system with the Lens Opacities Classification System III grading score and visual acuity in age-related nuclear cataract , 2008, British Journal of Ophthalmology.

[29]  E. Colombo,et al.  Discrimination between Surgical and Nonsurgical Nuclear Cataracts Based on ROC Analysis , 2014, Current eye research.

[30]  J. Alió,et al.  Grading nuclear cataract opacity by densitometry and objective optical analysis , 2008, Journal of cataract and refractive surgery.

[31]  Jaume Pujol,et al.  Effects of aging on optical quality and visual function , 2016, Clinical & experimental optometry.

[32]  M. Greiner,et al.  Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests. , 2000, Preventive veterinary medicine.

[33]  C. Costagliola,et al.  Quality of vision in patients implanted with aspherical and spherical intraocular lens: Intraindividual comparison , 2014, Indian journal of ophthalmology.

[34]  P. Asbell,et al.  Age-related cataract , 2005, The Lancet.

[35]  Beth T. Stalvey,et al.  Timed Instrumental Activities of Daily Living Tasks: Relationship to Visual Function in Older Adults , 2001, Optometry and vision science : official publication of the American Academy of Optometry.

[36]  Siamak Zarei-Ghanavati,et al.  Cataracts in Diabetic Patients: A Review Article , 2008, Journal of ophthalmic & vision research.

[37]  Kwanghyun Lee,et al.  Comparison of optical quality parameters and ocular aberrations after wavefront-guided laser in-situ keratomileusis versus wavefront-guided laser epithelial keratomileusis for myopia , 2013, Graefe's Archive for Clinical and Experimental Ophthalmology.

[38]  P. Artal,et al.  Grading nuclear, cortical and posterior subcapsular cataracts using an objective scatter index measured with a double-pass system , 2012, British Journal of Ophthalmology.

[39]  M. C. Leske,et al.  The Lens Opacities Classification System III. The Longitudinal Study of Cataract Study Group. , 1993, Archives of ophthalmology.

[40]  Dilraj S Grewal,et al.  Correlation of nuclear cataract lens density using Scheimpflug images with Lens Opacities Classification System III and visual function. , 2009, Ophthalmology.

[41]  D. Atchison,et al.  Comparison of ocular modulation transfer function determined by a ray-tracing aberrometer and a double-pass system in early cataract patients. , 2014, Chinese medical journal.